Run # 1000 Normal good /* Stopped because anti-sorter died. */ Run # 1001 Normal good /* Stopped because anti-sorter died (segmentation fault). */ Run # 1002 Normal good /* Stopped because anti-sorter died. */ Run # 1003 Normal good /* Stopped because anti-sender died. */ Run # 1004 Normal good /* Stopped because anti-sender died. HV trip discovered in Hut 2 Channel 3.1 and Hut 3 Channel 1.7. */ Run # 1005 Normal good /* Stopped by slcserv:get_shm_id:can't find shared memory. Cleanup command issued. */ Run # 1006 Normal good /* Stopped because anti-sender died. There was no run summary. */ Run # 1007 Normal good /* Stopped because of probable nova problem (anti-sorter output buffer put back in as input buffer). Reset FSCC controller at 50,000 events. */ Run # 1008 Normal good /* Stopped because of nova problem. */ Run # 1009 Normal good /* "Crashed." */ Run # 1010 Normal good /* "Crashed." */ Run # 1011 Normal good /* "Crashed." */ Run # 1012 Normal good /* Stopped to try new nova_get */ Run # 1013 Normal good /* Stopped to check HV */ Run # 1014 Normal good /* Stopped by anti-sorter crash */ Run # 1015 Normal good /* Stopped by anti-sorter crash no run summary */ Run # 1016 Normal good /* Stopped because sukante sender died */ Run # 1017 Normal good /* Sorter on sukante died There was no run summary */ Run # 1018 Normal good /* Sorter on sukante died */ Run # 1019 Normal good /* Anti sender died */ Run # 1020 Normal good /* Sender on sukante died */ Run # 1021 Normal good /* Sender on sukante died */ Run # 1022 Normal good /* Anti sender died */ Run # 1023 Normal good /* Normal stop for Xe calibration */ Run # 1024 Xe bad /* Monitor data did not come */ Run # 1025 Xe bad /* Monitor data did not come */ Run # 1026 Xe bad /* Monitor data did not come */ Run # 1027 Xe bad /* Monitor data did not come */ Run # 1028 Xe bad /* Monitor data did not come */ Run # 1029 Xe bad /* Monitor data did not come */ Run # 1030 Xe bad /* Monitor data did not come */ Run # 1031 Xe bad /* Monitor data did not come */ Run # 1032 Xe good /* Normal stop */ Run # 1033 Xe good /* Normal stop */ Run # 1034 Xe good /* Normal stop */ Run # 1035 Xe good /* Normal stop */ Run # 1036 Xe good /* Normal stop */ Run # 1037 Xe good /* Normal stop */ Run # 1038 Xe good /* Normal stop */ Run # 1039 Xe good /* Normal stop */ Run # 1040 Xe good /* Normal stop */ Run # 1041 Xe good /* Normal stop */ Run # 1042 Xe good /* Normal stop */ Run # 1043 Xe good /* Normal stop */ Run # 1044 Xe good /* Normal stop */ Run # 1045 Xe good /* Normal stop */ Run # 1046 Xe good /* Normal stop */ Run # 1047 Xe good /* Normal stop */ Run # 1048 Normal good /* Stopped because of sender error */ Run # 1049 Normal bad /* Eventbuilder error No OD data on SCAN */ Run # 1050 Test bad /* Stopped because monitor not working */ Run # 1051 Test bad /* high rate switch off Normal stop */ Run # 1052 Normal good /* Server #10 ERROR DETECT-FORCE SLEEP */ Run # 1053 Normal good Run # 1054 Normal good Run # 1055 Normal bad /* Sukon4 errors from beginning Stopped because of eventbuilder errors */ Run # 1056 Normal bad /* Stop because of eventbuilder errors No OD data */ Run # 1057 Normal good /* Stopped Eventbuilder errors began 7:17 */ Run # 1058 Normal good /* Stop because of eventbuilder errors */ Run # 1059 Laser good /* Normal stop */ Run # 1060 Nonexistent bad Run # 1061 Nonexistent bad Run # 1062 Laser good /* Normal stop */ Run # 1063 Laser good /* Normal Stop */ Run # 1064 Laser bad Run # 1065 Laser good /* Normal Stop */ Run # 1066 Laser good /* Normal Stop */ Run # 1067 Normal bad Run # 1068 Test bad /* 57 microsecond veto following trigger */ Run # 1069 Test bad /* 57 microsecond veto following trigger */ Run # 1070 Normal good Run # 1071 Normal good Run # 1072 Normal good /* Stopped because sender died in anti */ Run # 1073 Normal good /* Sukonh::evbuild/TIMEOUT occured while selecting */ Run # 1074 Normal good /* Sukonh::evbuild/TIMEOUT occured while selecting */ Run # 1075 Normal good /* Sukonh::evbuild/TIMEOUT occured while selecting */ Run # 1076 Normal good /* Sukonh::evbuild/TIMEOUT occured while selecting The run summary that was written for this run is identical to run 1075 and is incorrectl */ Run # 1077 Normal good /* Operator stop at 8:53 Data stopped at 8:28 for unknown reason */ Run # 1078 Normal good /* Stopped because OD TDC busy */ Run # 1079 Normal good /* Stopped to disconnect OD Hut 3-5-2 */ Run # 1080 Normal bad /* doubtful run because of high event rate (sparking) */ Run # 1081 Normal bad /* doubtful run because of high event rate (sparking) */ Run # 1082 Normal bad /* doubtful run because of high event rate (sparking) */ Run # 1083 Normal good /* Hut 3-2-5-1, 3-2-13-9, 3-2-17-9, 3-2-20-3 jumpers removed before or during run */ Run # 1084 Normal bad /* Stopped because OD busy */ Run # 1085 Normal bad /* doubtful run because of TRG error discovered in run 1087. Stopped because OD busy */ Run # 1086 Normal bad /* doubtful run because of TRG error discovered in run 1087 */ Run # 1087 Normal bad /* Unknown number of subruns at beginning are bad. Noisy TRG line discovered with bad TRG pulse Repaired at 18:00 */ Run # 1088 Normal good /* FSCC reset at 19:50 is preceeded by about a 10 minute gap in anti-data Error in TDC event number Run summary is wrong (partly overwritten by run 1090) */ Run # 1089 Normal good Run # 1090 Normal good /* Stopped because of sukonxx errors */ Run # 1091 Normal good /* Data stopped by sukon1e errors */ Run # 1092 Normal good /* Run summary is wrong (overwritten by run 1090) */ Run # 1093 Normal good /* Stopped because of count error in Gong-37 */ Run # 1094 Normal bad /* This run was not mentioned in the logbook, but Run 1095, which followed it during the same shift, was a good , which was also not mentioned in the logbook There is a one hour gap between runs 1093 and 1095, enough time for a possibly good No run summary [Run probably Nonexistent] */ Run # 1095 Normal good Run # 1096 Normal good /* Stopped because of DAQ error */ Run # 1097 Normal good /* Stopped because of DAQ error */ Run # 1098 Normal good /* Stopped for DAQ study, which showed 16 bit event rollover incorrect Problem fixed for next run */ Run # 1099 Laser good /* Fiber 1/1 + 2/29 */ Run # 1100 Laser good /* Fiber 1/2 2/21 */ Run # 1101 Laser good /* Fiber 2/26 */ Run # 1102 Nonexistent bad /* Summary was overwritten from run 1103 and is wrong */ Run # 1103 Laser good /* Fiber 2/1 */ Run # 1104 Nonexistent bad /* Summary was overwritten from run 1103 and is wrong */ Run # 1105 Laser good /* Fiber 1 High */ Run # 1106 Laser good /* Fiber 2 Low */ Run # 1107 Laser good /* Stopped because OD busy Fiber 2 High */ Run # 1108 Laser good /* Fiber 2 High */ Run # 1109 Normal good /* HV errors No anti as of 03:15 (Hut 4 no matching event#) */ Run # 1110 Normal good /* Ended by sukante crash The original run summary is incorrect (overwritten by run 1111) */ Run # 1111 Normal good /* Anticollector had SIGALRM and stopped after 24528 events*/ Run # 1112 Normal good /* Normal Stop for LINAC test */ Run # 1113 Test bad /* LINAC test Normal Stop */ Run # 1114 Normal good /* Stopped because OD busy */ Run # 1115 Normal bad /* Stopped because OD busy There was no run summary */ Run # 1116 Normal bad /* Stopped because OD busy */ Run # 1117 Normal good /* No anti data at beginning because of bad cable */ Run # 1118 Laser bad /* No data */ Run # 1119 Laser bad /* Run summary is wrong */ Run # 1120 Laser good /* Fiber 2/15 + 2/16 */ Run # 1121 Laser good /* Fiber 2/11L */ Run # 1122 Laser good /* Fiber 2/21 */ Run # 1123 Laser good /* Fiber 2/4 */ Run # 1124 Laser good Run # 1125 Normal good /* called laser in logbook */ Run # 1126 Normal good /* Several thousand events at end with no TDC data */ Run # 1127 Normal good /* Stopped because no TDC data at end */ Run # 1128 Normal good /* OD busy in Hut 3 reset 10:50 (problem began at about event 159000) OD busy in Hut 4 reset 11:18 (problem began at aboutevent 174000) Stopped for data copying trouble from sukop to tape */ Run # 1129 Normal good /* Stopped because no OD data in last events */ Run # 1130 Normal good /* Normal Stop for header change */ Run # 1131 Normal good /* Stopped because antisender died */ Run # 1132 Normal good /* Stopped because OD busy in Hut 3 */ Run # 1133 Normal good /* Stopped because OD busy */ Run # 1134 Normal good /* DAQ test, probably good Stopped because sukant does not send TDC data */ Run # 1135 Normal good /* Stopped to install OD trigger threshold of 19 tubes */ Run # 1136 Normal bad /* OD busy in Hut 1 */ Run # 1137 Normal good /* OD trigger signal put into TRG, disconnected after run */ Run # 1138 Normal good /* Stopped by errors in sukant antisorter, antisender OD HV trip discovered at ebd of run in Hut 4 Channel 14 */ Run # 1139 Nonexistent Run # 1140 Normal bad /* Stopped because SCAN showed no OD data The logbook gives these times as corresponding to Run 1139 */ Run # 1140 Normal good /* Stopped by sukonh error 1996/sukonh::evbuild/TIMEOUT occured while selecting Best hypothesis is that there was no Run 1139, and there were two Run 1140s The second 1140 did not produce a run summary because of a cleanup following a sukonh crash This should not matter to people doing analysis, because no matter how one inter-prets this, only one good 1140 run and no good 1139 run */ Run # 1141 Normal good /* Stopped because of sukon sorter (Nova) errors */ Run # 1142 Normal good /* Stopped because of sukon8 error and Hut 3 busyOriginal run summary is wrong (overwritten by 1143) */ Run # 1143 Normal good /* Stopped because of evbuild errors */ Run # 1144 Normal good /* Stopped because of sukonh hangup At 06:45 an OD HV trip discovered in Hut 4, Channel 14 was enabled Original run summary is wrong (overwritten by 1143) */ Run # 1145 Normal good /* Stopped because of bad data from anti-DAQ:DPM1 */ Run # 1146 Normal good /* Stopped because anti-collector hung */ Run # 1147 Normal good /* Stopped because anti-collector hung */ Run # 1148 Normal good /* Normal Stop for anti-DAQ work */ Run # 1149 Normal good /* Normal Stop to recompile ID software */ Run # 1150 Normal good /* Normal Stop for ID software */ Run # 1151 Normal good /* Normal Stop to replace eventbuilder */ Run # 1152 Normal good Run # 1153 Normal good Run # 1154 Normal good /* Later data do not have OD data */ Run # 1155 Normal good /* Stopped because OD busy */ Run # 1156 Normal good /* Run summary overwritten by second Run 1156 */ Run # 1156 Normal good /* This run is also numbered 1156 */ Run # 1157 Normal good /* Hut 1 busy reset 23:50 Trip discovered for Hut 1 Channel 06 enabled 23:50 Hut 2 busy reset 00:25 Run Stopped 00:50 because of Hut 2 busy */ Run # 1158 Normal bad /* May be no data Stopped because of antisorter errors */ Run # 1159 Normal good /* Stopped because of antisorter errors Original run summary is wrong */ Run # 1160 Normal good /* Stopped because sukon9e event# Stopped (OD busy) */ Run # 1161 Normal good /* Stopped because evbuild/TIMEOUT Run summary shows no data but is probably wrong */ Run # 1162 Normal good /* Normal Stop to measure water transparency */ Run # 1163 Normal bad /* because of DAQ problems (no data) */ Run # 1164 Normal bad /* because of DAQ problems (no data) */ Run # 1165 Normal bad /* because of DAQ problems (no data) */ Run # 1166 Normal bad /* because of DAQ problems (no data) */ Run # 1167 Normal bad /* because of DAQ problems (no data) */ Run # 1168 Normal good Run # 1169 Normal good /* Normal Stop */ Run # 1170 Normal good /* Stopped because antisender dead */ Run # 1171 Normal good /* Stopped because antisender dead */ Run # 1172 Normal good /* Stopped because sukon5 collector dead*/ Run # 1173 Normal good /* Normal Stop for OD tests */ Run # 1174 Nonexistent bad /* There is no Run 1174 Its summary is a duplicate of Run 1173 and is false */ Run # 1175 Normal bad /* There is no record of termination in the logbook No run summary */ Run # 1176 Normal good /* Stopped because some collectors dead */ Run # 1177 Normal good /* Stopped because anti-sender dead Hut 1 Ch 06 was disabled until some time after run 1212Enabled 4/12 Original run summary wrong ( overwritten by 1176) */ Run # 1178 Normal good /* Stopped because of evbuild/TIMEOUT */ Run # 1179 Normal good /* Stopped because OD busy */ Run # 1180 Normal good /* Stopped because OD busy */ Run # 1181 Normal good /* Stopped because OD busy Original run summary is wrong (overwritten by 1182) */ Run # 1182 Normal bad /* No OD data */ Run # 1183 Normal good /* Stopped because OD busy */ Run # 1184 Normal good /* Stopped because antisorter dead */ Run # 1185 Normal good /* Stopped because no skim@kingfish */ Run # 1186 Normal good /* Stopped because no OD data Original run summary is wrong (overwritten by 1188) */ Run # 1187 Normal good Run # 1188 Normal good /* Stopped because OD busy A 20:19 OD busy was recovered */ Run # 1189 Normal good /* Stopped because OD busy There was no run summary */ Run # 1190 Normal good /* Stopped because OD busy There was no run summary */ Run # 1191 Normal good /* Stopped because OD busy There was no run summary because /export/online1 was "system full" */ Run # 1192 Normal good /* Stopped because OD busy Original summary wrong because /export/online1 was "system full" */ Run # 1193 Normal good /* Stopped because sukonh::evbuild/TIMEOUT */ Run # 1194 Normal good /* Stopped because anti-sender dead */ Run # 1195 Normal good /* Stopped because OD busy */ Run # 1196 Normal good /* Stopped because OD busy */ Run # 1197 Normal good /* Stopped because OD busy Has new FSCC code */ Run # 1198 Normal good /* At 11:15 Hut 4 Channel 29 was enabled Hut 3 Channel 02 was disabled and left off until run 1208 */ Run # 1199 Normal good Run # 1200 Normal good /* Stopped because no antidata */ Run # 1201 Normal good /* Normal Stop for online test */ Run # 1202 Normal bad /* Hut 2 was busy There was no run summary */ Run # 1203 Normal good /* Stopped because of anticollector errors which began 19:45 */ Run # 1204 Normal good /* Stopped because OD busy, all huts (SIGALRM) */ Run # 1205 Normal good /* Stopped because no OD data */ Run # 1206 Normal good Run # 1207 Normal good /* Collector was Stopped by operator test */ Run # 1208 Normal good /* Stopped because OD busy in all huts At 1:14 OD card at Hut 4-1-12 disabled At 1:36 OD HV pin 3-1-3-1 was removed and 3-1-3 was enabled 4-1-12 was enabled at the end of the run */ Run # 1209 Normal good /* Stopped because OD busy in all huts */ Run # 1210 Normal good /* Stopped because sukonh::evbuild/sender[10] dead */ Run # 1211 Normal good /* Stopped because no antidata */ Run # 1212 Normal bad /* Stopped because OD busy Hut 2 */ Run # 1213 Normal bad /* doubtful run Stopped by modifying OD software */ Run # 1213 Normal good /* Stopped because of sukon8e sorter/sender errors The original run summary calls this 1213, and the operators call this 1214 Both are unreliable, especially for runs 1213 to 1218, but it is my judgment that calling this 1213 would correspond to the smallest number of errors having been made */ Run # 1214 Nonexistent bad /* Its summary corresponds to a shortened version of run 1216 That, however, would require a double overwrite, which is not inconceivable given the abnormal halts of these runs */ Run # 1215 Normal good /* Normal Stop at request of anti-team */ Run # 1216 Normal bad /* Cleanup after some processes failed to stopThere was no run summary The double overwrite hypothesis (1216 summary overwrote 1214 before getting trashed itself) would indicate that this run started at 4/12 13:53:33 and ended 4/12 13:56:35 with a total of 1536 events at 84 Hz */ Run # 1217 Nonexistent bad /* There was no data in the first attempt at 1217 because of sukon 1-9 collector errors */ Run # 1218 Normal good /* Abort-cleanup The operator believes he mistakenly made this run 1217, but the run summary (partly trashed) lists this as run 1218 */ Run # 1218 Normal good /* Stopped because OD busy Summary destroyed by cleanup */ Run # 1219 Normal good /* Stopped because OD busy */ Run # 1220 Normal good Run # 1221 Normal good /* Frequent only anti HEADER starting 4:18:41 Antisender died 5:10 */ Run # 1222 Normal good Run # 1223 Normal bad /* OD busy Hut 2 */ Run # 1224 Normal bad /* OD busy Hut 2 */ Run # 1225 Normal good /* Stopped because of Hut 4 sorter/error */ Run # 1226 Normal bad /* OD busy Hut 2 */ Run # 1227 Normal good /* Stopped There was no run summary */ Run # 1228 Normal bad /* Only anti HEADER throughout run (no OD data) No run summary */ Run # 1229 Normal good /* Stopped because sender[10] dead Probably no OD data after 09:43 */ Run # 1230 Normal good /* Stopped because only anti HEADER (no OD data) */ Run # 1231 Normal good /* Sukon7 GONG in Hut 4 at 12:12 Sukon4/sorter error 12:42 */ Run # 1232 Normal bad /* No sender data Much of original summary overwritten */ Run # 1233 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1234 Normal bad /* No data Sender error */ Run # 1235 Normal bad /* No data Sender error */ Run # 1236 Normal good /* Stopped because sukonh::evbuild/sender[10] dead */ Run # 1237 Normal bad /* Antisorter code showed bad data on SCAN */ Run # 1238 Normal good Run # 1239 Normal good /* Stopped because sukonh::evbuild/sender[10] dead */ Run # 1240 Normal good /* At 01:45 autoreformat was not running */ Run # 1241 Normal bad /* No data Antitrigger off */ Run # 1242 Normal bad /* Antisender dead */ Run # 1243 Random trigger, bad /* No data */ Run # 1244 Normal good /* Stopped because no anti-data */ Run # 1245 Normal good /* Stopped because of sukon4 sorter stop Last quarter of run has one eighth of ID off */ Run # 1246 Normal good /* Stopped because sender [10] dead */ Run # 1247 Normal bad /* No data */ Run # 1248 Normal good /* Stopped by evbuild/TIMEOUT */ Run # 1249 Normal bad /* No data Collector not running */ Run # 1250 Normal bad /* No data Collector not running */ Run # 1251 Normal bad /* No data Collector not running */ Run # 1252 Normal bad /* No data Collector not running */ Run # 1253 Test bad /* No data */ Run # 1254 Normal bad /* Stopped by sorter, sender not created */ Run # 1255 Normal bad /* No data Sukon7 did not run */ Run # 1256 Normal bad /* Sukon7 did not run */ Run # 1257 Normal bad /* Only anti HEADER (no OD data) */ Run # 1258 Normal good /* Normal Stop to allow reformatting */ Run # 1259 Normal good /* Normal Stop to allow reformatting */ Run # 1260 Normal bad /* Connection failed */ Run # 1261 Normal good /* Normal Stop */ Run # 1262 Normal good /* Normal Stop */ Run # 1263 Normal good /* Stopped because sender [10] dead */ Run # 1264 Normal good /* Stopped because only anti HEADER (no OD data) */ Run # 1265 Normal other /* partly good Gong count error after 8 minutes Probably only first data file of this run is good */ Run # 1266 Normal bad /* No data */ Run # 1267 Normal good /* Normal Stop for software improvement */ Run # 1268 Normal bad /* Error in antisorter */ Run # 1269 Normal good /* Gong errors at 1:55 Stopped by antisender dead Last half of run may be bad */ Run # 1270 Normal good /* Stopped by sukon1sender, sukantesorter dead */ Run # 1271 Normal good /* Stopped because OD busy */ Run # 1272 Normal good /* Stopped because of pmonitor trouble */ Run # 1273 Normal good /* Stopped because of pmonitor trouble */ Run # 1274 Normal good /* Normal Stop OD busy Hut 2 for ten minutes then reset FSCC Hut 2 (first file may be bad because no OD data) */ Run # 1275 Normal good /* Normal Stop */ Run # 1276 Ni+Cf bad Run # 1277 Ni+Cf bad Run # 1278 Ni+Cf bad Run # 1279 Ni+Cf good /* (Th=150,353,-707,-12009) */ Run # 1280 Cf good /* (Th=150,353,-707,-12009) */ Run # 1281 Ni good /* (Th=150,353,-707,-12009) */ Run # 1282 Ni+Cf bad Run # 1283 Ni+Cf good /* (Th=150,353,-707,-09) Stopped, sukon9 dead */ Run # 1284 Ni+Cf good /* (Th=150,353,-707,-09) */ Run # 1285 Ni+Cf good /* (Th=150,353,-707,11191) This z only exceeds the central position by 1120 but is what was reported by the calibration group */ Run # 1286 Cf good /* (Th=150,353,-707,-09) */ Run # 1287 Cf good /* (Th=150,353,-707,11199) Again, z = center + 1120 */ Run # 1288 Normal bad Run # 1289 Normal bad /* OD collector cannot read data */ Run # 1290 Normal good /* Normal Stop to use internal soft latch instead of external con: excom -> incom for anti-DAQ */ Run # 1291 Nonexistent bad Run # 1292 Normal good /* Stopped because antisender dead */ Run # 1293 Normal good /* Stopped because sorter/sds serial count error */ Run # 1294 Normal good /* Stopped because pmonitor/collector died, sukon9e */ Run # 1295 Normal good /* Normal Stop to start laser run */ Run # 1296 Normal bad /* There was both a normal and a Laser trigger. Stopped because of anti-sorter segmentation fault */ Run # 1297 Normal bad /* Trigger was Laser + normal - anti, Normal Stop */ Run # 1298 Laser bad /* Aborted */ Run # 1299 Laser good /* ID Hut 4 only OD all */ Run # 1300 Laser good /* Stopped because FSCC Hut 3 dead */ Run # 1301 Laser bad /* no data */ Run # 1302 Normal bad /* HV errors */ Run # 1303 Normal bad /* Cable from central hut to Hut 3 disconnected */ Run # 1304 Normal good /* Stopped because of sorter errors */ Run # 1305 Normal good /* Stopped by central hut power failure */ Run # 1306 Normal bad /* doubtful run Stopped because not checking on "raw data save" */ Run # 1307 Normal bad /* Sender[10] dead */ Run # 1308 Normal good /* Data flow Stopped before operator Stopped run */ Run # 1309 Normal bad /* doubtful run Stopped because not checking on "raw data save" */ Run # 1310 Normal good Run # 1311 Laser good Run # 1312 Ni bad /* Aborted */ Run # 1313 Nonexistent bad /* Logbook says this run NonexistentTimes for this run given in the original summary put it between 1311 and 1312 Original summary may be an overwrite from an aborted first attempt at run 1312 */ Run # 1314 Nonexistent bad /* Original summary is an overwrite from run 1322 */ Run # 1315 Laser good /*Laser trigger on anti (T+6-1/B+2-2) Aborted Logbook calls this run 1314 */ Run # 1315 Laser good /* Laser trigger on anti (T+6-1/B+2-2) */ Run # 1316 Laser good /* Laser trigger on anti, W3L, W9H Aborted */ Run # 1317 Laser bad /* Laser trigger on anti, W5L, W11H Aborted */ Run # 1318 Laser bad /* Laser trigger on anti, W5L, W11H Aborted */ Run # 1319 Laser good /* Laser trigger on anti, W5L, W11H Aborted */ Run # 1320 Laser good /* trigger on anti, W3H, W10L Stopped when anticollector died Reboot caused original run summary to be overwritten by run 1316 */ Run # 1321 Laser good /* trigger on anti, W6H, W12L */ Run # 1322 Normal good /* Stopped when antisender died */ Run # 1323 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1324 Normal bad /* ATM-event counter cable discovered not to have been connected correctly */ Run # 1325 Normal good /* Stopped when antidetector process died */ Run # 1326 Normal good Run # 1327 Test bad /* Reboot destroyed run summary, which run 1326 overwrote */ Run # 1328 Test bad /* No OD */ Run # 1329 Test bad /* No OD */ Run # 1330 Test bad /* No OD */ Run # 1331 Test bad /* No OD */ Run # 1332 Normal bad /* No run summary */ Run # 1333 Normal good /* Stopped because antisender died */ Run # 1334 Normal good /* Normal Stop to upgrade collector */ Run # 1335 Normal good /* Stopped because Hut 3 busy */ Run # 1336 Normal bad /* Hut 4 busy */ Run # 1337 Normal bad /* Anticollector did not start */ Run # 1338 Normal good /* Evbuild error 05:03 Antisorter died 12:11/export/online:file system full Original run summary overwritten by 1331 */ Run # 1339 Normal good /* Stopped because antisorter died */ Run # 1340 Normal good Run # 1341 Normal bad /* Test run */ Run # 1342 Normal bad /* Test run */ Run # 1343 Laser good /* Filter:1250, SW1:9, SW2:0, 10Hz */ Run # 1344 Laser good /* Filter:1250, SW1:9, SW2:0, 10Hz */ Run # 1345 Laser good /* Filter:1450, SW1:9, SW2:0, 10Hz */ Run # 1346 Laser good /* Filter:1400, SW1:9, SW2:0, 10Hz */ Run # 1347 Laser good /* Filter:1350, SW1:9, SW2:0, 10Hz */ Run # 1348 Laser good /* Filter:1300, SW1:9, SW2:0, 10Hz */ Run # 1349 Laser good /* Filter:1250, SW1:9, SW2:0, 10Hz */ Run # 1350 Laser good /* Filter:1200, SW1:9, SW2:0, 10Hz */ Run # 1351 Laser good /* Filter:1150, SW1:9, SW2:0, 10Hz */ Run # 1352 Laser good /* Filter:1100, SW1:9, SW2:0, 10Hz */ Run # 1353 Laser good /* Filter:1050, SW1:9, SW2:0, 10Hz */ Run # 1354 Laser good /* Filter:1000, SW1:9, SW2:0, 10Hz */ Run # 1355 Laser good /* Filter:950, SW1:9, SW2:0, 10Hz */ Run # 1356 Laser good /* Filter:900, SW1:9, SW2:0, 10Hz */ Run # 1357 Laser good /* Filter:850, SW1:9, SW2:0, 10Hz */ Run # 1358 Laser good /* Filter:800, SW1:9, SW2:0, 10Hz */ Run # 1359 Laser good /* Filter:750, SW1:9, SW2:0, 10Hz */ Run # 1360 Laser good /* Filter:700, SW1:9, SW2:0, 10Hz */ Run # 1361 Laser good /* Filter:650, SW1:9, SW2:0, 10Hz */ Run # 1362 Laser good /* Filter:600, SW1:9, SW2:0, 10Hz */ Run # 1363 Laser good /* Filter:550, SW1:9, SW2:0, 10Hz */ Run # 1364 Laser good /* Filter:500, SW1:9, SW2:0, 10Hz */ Run # 1365 Laser good /* Filter:450, SW1:9, SW2:0, 10Hz */ Run # 1366 Xe good Run # 1367 Normal bad /* Hut 2 busy */ Run # 1368 Normal bad /* Anticollector not running */ Run # 1369 Normal good /* Stopped because no OD data */ Run # 1370 Normal good /* Stopped because evbuild/sender[2] dead */ Run # 1371 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1372 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1373 Normal good /* Stopped because antisorter, anticollector died */ Run # 1374 Normal good /* Aborted */ Run # 1375 Ni good /* trigger w/o source High rate test run */ Run # 1376 Ni good /* trigger w/o source High rate test run */ Run # 1377 Ni good /* trigger w/o source High rate test run */ Run # 1378 Normal bad /* OD trigger delay wrong */ Run # 1379 Normal bad /* Data taking delayed by beep pileup */ Run # 1380 Normal good Run # 1381 Normal good /* Stopped because sender on sukon3 died */ Run # 1382 Normal good /* Stopped because antisorter died */ Run # 1383 Normal good /* Stopped because antisorter, antisender died */ Run # 1384 Normal good /* Normal Stop to replace online software */ Run # 1385 Normal bad /* Anticollector does not work */ Run # 1386 Normal bad /* Anticollector does not work */ Run # 1387 Normal bad /* Anticollector does not work */ Run # 1388 Normal good /* Stopped because sukante sender died */ Run # 1389 Normal good /* Stopped because OD busy Hut 4 */ Run # 1390 Normal good /* Normal Stop for software change */ Run # 1391 Normal good /* Normal Stop to do calibration */ Run # 1392 Laser good /* on anti W12H, W6L */ Run # 1393 Laser bad /* on anti */ Run # 1394 Laser good /* on anti W10H, W4L */ Run # 1395 Normal bad /* OD pedestal run Random trigger OFF ANTI trigger */ Run # 1396 Normal good /* Stopped because part of OD data not sent */ Run # 1397 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1398 Normal bad /* No data */ Run # 1399 Normal good /* Normal Stop for software change */ Run # 1400 Normal good /* Normal Stop to do laser runs */ Run # 1401 Laser good /* on anti W5H/W9L ID HV off Losing anti-data at high light levels because of reduced DPM page size Size restored to higher size at end of run */ Run # 1402 Laser good /* on anti W4H/W8H */ Run # 1403 Normal good /* OD HV Hut 3, Channel 114 trip discovered 5:00Near 5:40 attempts were made to enable OD HV Hut 2, channel 32 Current rose Left off until 6:00 and then successfully enabled OD HV Hut 1,Channel 32 tripped discovered and enabled Antisorter died at 7:15 */ Run # 1404 Normal bad /* "New run is not running" in process monitor */ Run # 1405 Normal good /* Stopped because sender [10] dead */ Run # 1406 Normal bad /* "New run is not running" in process monitor */ Run # 1407 Normal good Run # 1408 Normal good /* Normal Stop for software change OD HV for Hut 2 Crate 2 cards 18, 19, 20 disabled 10:50 Cards 11-17 on same cratedisabled 11:04 All were enabled at 11:34 after removing jumper for Hut 2-2-19-4 */ Run # 1409 Normal good /* Normal Stop for software change */ Run # 1410 Normal good /* Normal Stop to start trigger efficiency test */ Run # 1411 Normal bad /* TRG test */ Run # 1412 Normal bad /* TRG test 32 hit 380 mV (logbook says 36 hits) */ Run # 1413 Normal bad /* TRG test 32 hit 360 mV */ Run # 1414 Normal bad /* TRG test 28 hit 320 mV */ Run # 1415 Nonexistent bad Run # 1416 Normal bad /* TRG test 24 hit 280 mV */ Run # 1417 Normal bad /* Random trigger */ Run # 1418 Ni good /* (3535, -707, 00) */ Run # 1419 Ni good /* no source */ Run # 1420 Normal bad /* No OD data */ Run # 1421 Normal good Run # 1422 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1423 Normal bad /* No data */ Run # 1424 Normal good /* Normal Stop to change board for sukon9 */ Run # 1425 Nonexistent bad Run # 1426 Normal good /* Stopped because of only anti HEADER (no OD data) OD HV Hut 3 channels 06 to 09 disabled from 15:50 to 16:27 */ Run # 1427 Normal bad /* No data */ Run # 1428 Normal good /* Stopped because sukon5 died OD Hut 4 Stopped 18:45 Reset FSCC after a few minutes */ Run # 1429 Normal good /* Stopped because sukon3e not connected via ethernet */ Run # 1430 Normal good /* Stopped because sukante sender died At 2:30 OD HV Hut 2 Channel 210 was reset after a trip At 4:12 it was reset again */ Run # 1431 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1432 Normal bad /* No data */ Run # 1433 Normal good /* Normal Stop to exchange hard disk of sukon5 */ Run # 1434 Normal good /* Stopped because of evbuild count error */ Run # 1435 Normal good /* Stopped because sender at sukant was dead at 21:36 */ Run # 1436 Normal good /* Stopped because OD busy at Hut 2 */ Run # 1437 Normal bad /* No data */ Run # 1438 Normal good /* At 01:00 OD HV Hut 2 Channel 00 was reset after trip discovered Reset again after trip discovered at 03:10 At 06:09 there was a sukonh crash and reboot No Run summary was made */ Run # 1439 Normal good /* Stopped because of anticounter errors At 2:00 OD HV at Hut 1, Channel 01 was disabled, and it was reset at 04:25At 2:20 an OD HV trip at Hut 2, Channel 32 was reset An OD HV trip at Hut 1, Channel 18 was reset at 3:00 and again at 4:30 */ Run # 1440 Normal good /* Hut 2 was Stopped by operator error at 10:00 Operator estimates last 1000 events had no OD data This estimate corresponds to Hut 2 being off for 100 seconds before the Run Stopped, which is not what was reported in the logbook */ Run # 1441 Normal bad /* Anticollector did not start */ Run # 1442 Normal good /* Normal Stop for OD maintenance */ Run # 1443 Normal good /* Stopped because "evbuild/TIMEOUT occured while selecting" sorter@sukon3 error No Run summary was made */ Run # 1444 Normal good /* Normal Stop. ATM flag incorrect for event #854159 to 854189 At 0:45 OD HV trips for Hut 1, channel 01 and Hut 2, Channel 211 were reset At 04:30 an OD HV trip for Hut 3, channel 11 was reset At 9:58 OD HV for Hut 3 channels 09 to 011 were disabled The jumper was removed from 3-1-13-3 and OD HV for 09 to 011 were enabled at 10:58 */ Run # 1445 Normal good /* Stopped because OD busy Hut 3 Last two files probably bad subRuns for this reason */ Run # 1446 Normal good /* Stopped because sender[10] dead at 15:27GONG count error 13:00 OD HV Hut 4 disabled from beginning of Run until 11:46, when they were enabled with jumper 4-1-13-10 removed */ Run # 1447 Normal good /* Normal Stop to do Ni Runs At 23:00 an OD HV trip that was discovered at Hut 2, Channel 00 It tripped again later and was enabled at 00:00 */ Run # 1448 Nonexistent bad Run # 1449 Ni bad /* (353,-707,00), doubtful because correction factor 23 had wrong sign GONG count error */ Run # 1450 Ni bad /* (353,-707,1600), doubtful because correction factor 23 had wrong sign GONG count error */ Run # 1451 Ni bad /* (353,-707,1200), doubtful because correction factor 23 had wrong sign GONG count error */ Run # 1452 Ni bad /* (353,-707,0), doubtful because correction factor 23 had wrong sign GONG count error */ Run # 1453 Nonexistent bad Run # 1454 Ni good /* (353,-707,1600) */ Run # 1455 Ni good /* (353,-707,1200) */ Run # 1456 Ni good /* (353,-707,800) */ Run # 1457 Ni good /* (353,-707,400) */ Run # 1458 Nonexistent bad Run # 1459 Ni good /* (353,-707,60) Sukon 8,6,7,1 sorter emergency stop (not enough outbuf size) */ Run # 1460 Nonexistent bad Run # 1461 Ni good /* (353,-707,60) Aborted with comment "may not exist" */ Run # 1462 Nonexistent bad Run # 1463 Ni good /* (353,-707,0) */ Run # 1464 Ni good /* (353,-707,-400) */ Run # 1465 Nonexistent bad Run # 1466 Ni good /* (353,-707,-800) */ Run # 1467 Ni good /* (353,-707,-1200) */ Run # 1468 Ni good /* (353,-707,-1140) */ Run # 1469 Ni good /* (353,-707,-1600) */ Run # 1470 Normal good /* No anti-data for the first 20 minutes; then, reset FSCC in Hut 2 At 23:10 reset FSCC in Hut 4 in response to FSCC trouble At 01:06 disk full, selector didn't work Halted with no Run summary written When it ended the comments Ni trigger (should have been normal) and LE thr 150 (should have been 320) were in the selector window */ Run # 1471 Normal good /* Anti processes dead at 2:56 */ Run # 1472 Normal good /* Normal Stop to install new anticollector An OD busy occured early in the Run (TDC LEDs not flashing) */ Run # 1473 Normal good /* Stopped because at 17:28 segmentation fault, Hut 3, sukante sorter */ Run # 1474 Normal good /* Normal Stop to do transparency test OD HV trip discovered Hut 2, Channel 211 at 18:05 */ Run # 1475 Normal bad /* OD busy Hut 2 */ Run # 1476 Normal bad /* Sender counter does not work */ Run # 1477 Normal bad /* OD error */ Run # 1478 Normal good /* OD HV off until 4:40 (about two subRuns, ie, tape files of OD off) Stopped because antisorter and antisender @sukant dead at 9:37 */ Run # 1479 Normal good /* Normal Stop for software change OD HV Hut 3 channels 04 to 06 were disabled from 10:33 to 10:49 OD HV Hut 2 channels 210, 211, 30, 31 were disabled from 11:05 to 11:14 */ Run # 1480 Normal bad /* No data sent */ Run # 1481 Normal good /* Normal Stop to test ATM */ Run # 1482 Normal bad /* because ATM test not finished */ Run # 1483 Normal bad /* No anti data */ Run # 1484 Normal good /* Normal Stop */ Run # 1485 Normal good /* (at least mostly good) Normal Stop requested by offline because middle energy data stream had trouble since 03:00 */ Run # 1486 Normal bad /* No data */ Run # 1487 Normal good /* Aborted after a Normal Stop for software change failed */ Run # 1488 Nonexistent bad /* There is no Run summary for 1488 What is listed in the logbook as 1488 is listed in the Run summary as 1490, so see Run 1490 */ Run # 1489 Normal good /* Normal Stop at offline request because Run numbers confused */ Run # 1490 Normal bad /* Listed in logbook, which claims Run 1490 does not exist, as Run 1488 Listed in Run summary, which claims 1488 does not exist, as Run 1490 Anticollector status errors from the beginning Hut 2 busy reset 18:20 Hut 3 segmentation fault at 18:30, so antisorter dies, bus error */ Run # 1491 Normal good /* Normal Stop to change ID HV board */ Run # 1492 Normal good /* Normal Stop to put in GPS diagnosis OD busy Hut 2 reset at 09:04 */ Run # 1493 Normal good /* Stopped because antisender died GPS time correct */ Run # 1494 Normal good /* Stopped because antisender died GPS time correct */ Run # 1495 Normal good /* Stopped because sorters died GPS out */ Run # 1496 Normal good /* OD HV Hut 4, Channels 10,11,12 disabled from beginning of Run until 11:10 At 11:13 OD HV Hut 2, Ch 211 was reset after a trip At 16:40 "Events missing (0)" errors began OD busy Hut 3 was reset 17:12 Data taken after 16:40 should be regarded as doubtful */ Run # 1497 Normal bad /* because of continued "Events missing(0)" errors */ Run # 1498 Normal good /* Normal Stop for software change */ Run # 1499 Normal good /* Normal Stop for software change */ Run # 1500 Normal bad /* OD busy Hut 2 */ Run # 1501 Normal good /* Stopped because of anticollector segmentation fault */ Run # 1502 Normal good /* OD busy Hut 4 reset 07:35 */ Run # 1503 Normal good /* Stopped because sender dead */ Run # 1504 Normal bad /* Hut 2 busy from beginning recovered at 9:12 Continued frequent errors in anticollector@sukant Halted with no Run summary written */ Run # 1505 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1506 Normal good /* OD busy Hut 2 reset 15:10 */ Run # 1507 Normal bad /* Antisender/NOVA errors (Hut 2) */ Run # 1508 Normal bad /* Antisender/NOVA errors (Hut 2) */ Run # 1509 Normal bad /* Hut 2 errors (broken cable) */ Run # 1510 Normal bad /* Hut 2 errors */ Run # 1511 Normal bad /* Hut 2 errors */ Run # 1512 Ni bad /* z=-12 Sukant server in selector off */ Run # 1513 Ni good /* z=-12 GONG count error */ Run # 1514 Ni good /* z=0 Evbuild error, file system ful */ Run # 1515 Nonexistent bad Run # 1516 Nonexistent bad Run # 1517 Ni good /* z=12 */ Run # 1518 Normal good /* Normal Stop OD busy reset Hut 2, 12:02, 12:20 */ Run # 1519 Normal good /* Stopped because of sukon7, sukon8 sorter/sds serial count errors */ Run # 1520 Normal good /* Normal Stop */ Run # 1521 Normal bad /* because no OD (sukante off) Normal Stop requested by offline */ Run # 1522 Normal bad /* Run Halted by sukonh reboot with no Run summary *Itis my reading of the logbook that sukante remained off through Run 1526, in which case all of the Runs from 1521 to 1526 are bad because of no OD data If I am wrong, then all the bad* Runs are good */ Run # 1523 Normal bad /* HV-network connector (described as 1 hut 11 crate) discovered broken 00:35 and replaced */ Run # 1524 Normal bad /* Arcing in Hut 3 until 12:30 Hut 3 Crate 1 (all of it) disabled 12:30 Enabled 13:20, disabled, then enabled with Hut 3 Channel 08 disabled At 14:30 HV off Hut 3 At 14:47 HV on Hut 3 except for Channel 08 for the rest of the Run */ Run # 1525 Normal bad /* Normal Stop for software change Run began with Hut 3, Ch 08 disabled At 17:15 H 3 Ch 07 and 09 also disabled All three channels enabled 18:15 with 3-1-9-4 removed At 18:17 Hut 4 Ch 010 to 012 were disabled All were enabled at 19:00 wuth 4-1-12-12 removed */ Run # 1526 Normal bad /* Stopped to integrate anticounter */ Run # 1527 Normal good /* Stopped because sukant Stopped */ Run # 1528 Normal good /* Normal Stop requested by offline */ Run # 1529 Normal good /* Stopped because sender dead */ Run # 1530 Normal bad /* because no antidata Stopped because sukante sorter/sender dead */ Run # 1531 Normal bad /* because no antidata Normal Stop to measure water transparency */ Run # 1532 Normal good /* (except first subRun probably bad) Normal Stop requested by offline OD BUSY: HUT2 turned out to be latch cable problem in Hut 1 Fixed after about 8000 events */ Run # 1533 Normal good /* (except OD trigger failed second half) Stopped because of only anti HEADER (no OD data) Logbook estimates there was OD data but no OD trigger from 12:30 to 17:32 */ Run # 1534 Normal good /* (except OD trigger not working), Normal Stop requested by offline */ Run # 1535 Normal good /* (except OD trigger not working) */ Run # 1536 Normal good /* Hut 1 and 3 busy reset at 18:12 */ Run # 1537 Normal bad /* Reset of Hut 2 busy failed to save antitrigger, which had Stopped by 18:50 Operators characterize this Run as junk There was no Run summary written */ Run # 1538 Normal bad /* perhaps two good subRuns in the middle Hut 3 busy from beginning, reset at 19:30 Several thousand events at end had no TDC dataFirst and last full subRuns probably bad */ Run # 1539 Normal good /* Normal Stop for hardware repair */ Run # 1540 Normal good /* Stopped because skimexe dead */ Run # 1541 Normal good /* Normal Stop for antisorter software upgrade SubRun 8 lost in reformat error */ Run # 1542 Normal good /* Normal Stop for anticollector software upgrade At 05:05 Hut 1 FSCC was reset due to TDC event buffer mismatch */ Run # 1543 Normal good /* Stopped because sukant collector died */ Run # 1544 Normal good /* Stopped because sukant collector died Old anticollector software restored */ Run # 1545 Normal good /* OD HV Hut 2 Channel 011 had failed during Run, apparently by 08:55 Hut 2 Ch 00 had tripped by end of Run Both were enabled after Run Hut 1 Ch 210 also tripped by 08:55 Left off through Run 1547 */ Run # 1546 Normal good /* Normal Stop */ Run # 1547 Normal good /* Normal Stop At end of Run Jumper 1-2-15-6 removed and Card 1-2-15 enabled at 2200 Volts (correct is 2250) */ Run # 1548 Normal good /* Stopped because of no antidata */ Run # 1549 Normal good /* Normal Stop */ Run # 1550 Normal bad /* No data NOVA error */ Run # 1551 Normal bad /* because called junk by operators */ Run # 1552 Normal good /* Normal Stop for software upgrade */ Run # 1553 Normal good /* Stopped because antisender died */ Run # 1554 Normal good /* Stopped because OD busy Hut 3 */ Run # 1555 Normal good /* Normal Stop requested by offline */ Run # 1556 Normal good /* Normal Stop requested by offline */ Run # 1557 Normal good /* Sukant Stopped collecting events after about 4000 events at 1:35 No Run summary written */ Run # 1558 Normal good /* Normal Stop for software upgrade */ Run # 1559 Normal good /* Stopped because of anticollector crash */ Run # 1560 Normal good /* Stopped because of anticollector crash */ Run # 1561 Normal good /* Normal Stop requested by offline */ Run # 1562 Normal good /* Stopped because of sukante crash OD HV trip discovered 09:10 for Hut 2, #672-683 Enabled at 10:05 After the Run, PMT 1-8-18-1, identified as a flasher, was disabled */ Run # 1563 Ni good /* z = -12, upside down */ Run # 1564 Ni good /* z = 0, upside down */ Run # 1565 Ni good /* z = 12, upside down PMT 3-3-13-6 identified as flasher */ Run # 1566 Ni good /* z = -12 */ Run # 1567 Ni good /* z = 0 */ Run # 1568 Ni good /* z = 12 Stopped because of evbuild timeout */ Run # 1569 Nonexistent bad Run # 1570 Ni good /* z = 12 */ Run # 1571 Normal bad /* without sukant, probably bad for that reason */ Run # 1572 Normal good /* Stopped because antisender does not send data No Run summary */ Run # 1573 Normal good /* Stopped because OD performance went down to 90% No Run summary written */ Run # 1574 Normal bad /* ID/OD data mismatch No Run summary written */ Run # 1575 Normal bad /* Characterized by operators as junk No Run summary written */ Run # 1576 Normal bad /* ID/OD data mismatch No Run summary written */ Run # 1577 Normal bad /* ID/OD data mismatch No Run summary written */ Run # 1578 Normal bad /* ID/OD data mismatch */ Run # 1579 Normal good /* Stopped because OD efficiency fell to 85% */ Run # 1580 Normal good /* Stopped because of ID/OD data mismatch */ Run # 1581 Normal bad /* ID/OD data mismatch */ Run # 1582 Normal bad /* No OD data */ Run # 1583 Normal bad /* No data OD busy Hut 1 */ Run # 1584 Normal good /* Stopped because of ID/OD data mismatch */ Run # 1585 Normal good /* Stopped because of ID/OD data mismatch */ Run # 1586 Normal good /* Stopped because other flag detected */ Run # 1587 Normal bad /* Anticollector dead No data nor Run summary */ Run # 1588 Normal bad /* Anticollector dead No data nor Run summary */ Run # 1589 Normal bad /* ID/OD data mismatch No Run summary written */ Run # 1590 Normal bad /* Aborted No data nor Run summary */ Run # 1591 Normal good /* Halted by sukonh error with no Run summary */ Run # 1592 Normal bad /* maybe one good subRun Stopped because of no OD */ Run # 1593 Normal good /* Normal Stop for software upgrade */ Run # 1594 Normal good /* GONG count error Welding on top of tank blamed with good indirect evidence for high rate in OD */ Run # 1595 Normal good /* GONG count error Welding on top of tank blamed with good indirect evidence for high rate in OD */ Run # 1596 Normal bad /* OD busy Hut 3 No data */ Run # 1597 Normal good /* Check sum error Other error */ Run # 1598 Normal bad /* No data */ Run # 1599 Normal good /* Stopped because no OD data At 17:26 OD PMTs 1-2-20-4, 1-1-1-4, and 2-1-10-12 were disabled */ Run # 1600 Normal bad /* No data */ Run # 1601 Normal bad /* No OD data */ Run # 1602 Normal good /* Stopped because antisender died */ Run # 1603 Normal good /* good except for last subRun No OD data last 5 minutes */ Run # 1604 Normal bad /* No data OD busy Hut 2 */ Run # 1605 Normal good /* Stopped because of antisorter hexes */ Run # 1606 Normal good /* Stopped because sukon7 stopped */ Run # 1607 Normal bad /* No data */ Run # 1608 Normal good /* Stopped because of OD data mismatch */ Run # 1609 Normal good /* Welding again. Stopped because of ID/OD mismatch */ Run # 1610 Normal good /* Stopped because of FSCC lock */ Run # 1611 Normal good /* Stopped because of FSCC lock */ Run # 1612 Normal bad /* Stopped because of no antidata */ Run # 1613 Normal good /* High data rate caused by OD Hut 2-2-2-9 arcing Pin removed during Run, causing rate to reduce to normal */ Run # 1614 Normal good /* Stopped because of anti-mismatch */ Run # 1615 Normal good /* From 3-3:30 several OD HV were temporarily discon-nected OD HV card 3-9-5 was disconnected then enabledThen 3-12-13 wasdisconnected then enabled, then 3-2-7 Finally at 3:30 pin 3-2-7-10 was pulled, and then 3-2-7 was enabled */ Run # 1616 Normal good /* Stopped because anti-efficiency dropped to 85% */ Run # 1617 Normal bad /* No data */ Run # 1618 Normal good /* Normal Stop for OD DAQ software upgrade */ Run # 1619 Normal good /* Stopped because of no OD data */ Run # 1620 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1621 Normal bad /* OD busy Hut 2 */ Run # 1622 Normal good /* Stopped because OD died (hex from Hut 4) */ Run # 1623 Normal good /* Stopped because of OD data mismatch */ Run # 1624 Normal good /* Invalid ATM flag, 15:47 */ Run # 1625 Normal good /* Stopped because of no OD data */ Run # 1626 Normal good /* Stopped because antisender stopped */ Run # 1627 Normal good /* Stopped because of OTHER FLAG */ Run # 1628 Normal bad /* No data OD busy */ Run # 1629 Normal bad /* Antidata mismatch */ Run # 1630 Normal good /* Stopped because anti-efficiency dropped to 80% At 01:50 OD HV trip in Hut 2, Channel 00 was reset */ Run # 1631 Normal bad /* No data FIFO busy */ Run # 1632 Normal good /* Stopped because of ATM FIFO overflow */ Run # 1633 Normal good /* Normal Stop at offline request At 06:10 an OD HV trip was discovered, Hut 2 Ch 25 Pin 2-2-10-6 was pulled */ Run # 1634 Normal good /* Stopped because of evbuild/TIMEOUT CHECK SUM at 10:22 */ Run # 1635 Normal good /* Normal Stop. Removed OD HV pin 2-2-17-7 at 17:00 */ Run # 1636 Normal good /* Stopped because of OTHER FLAG */ Run # 1637 Normal bad /* No OD */ Run # 1638 Normal good /* Stopped because of OTHER FLAG */ Run # 1639 Normal good /* Stopped because disk full */ Run # 1640 Normal good /* Normal Stop for OD inspection */ Run # 1641 Normal good /* Stopped because of sukonxx may be stopped, 11:18 */ Run # 1642 Normal good /* GONG count error */ Run # 1643 Normal good /* Normal Stop for software upgrade */ Run # 1644 Normal good /* Normal Stop to repair OD HV cards */ Run # 1645 Normal bad /* No data */ Run # 1646 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1647 Normal good /* Stopped because of only anti HEADER (no OD data) */ Run # 1648 Normal good /* Stopped because of no antidata CHECK SUM at 22:50 */ Run # 1649 Normal good /* Normal Stop */ Run # 1650 Normal good /* Stopped because of sorter/sds serial count error At 02:00 three OD HV trips were discovered and reset: Hut 2 Ch 00, Hut 2 Ch 14, and Hut 3 Ch 21 At 04:32 an OD busy in Hut 3 was reset */ Run # 1651 Normal bad /* No data */ Run # 1652 Normal good /* Stopped because of hex from sukant, OD efficiency dropped to 80% */ Run # 1653 Normal good /* Stopped when OD efficiency dropped to 85% OD HV trip discovered in Hut 2, Ch 14 reset 7:30 */ Run # 1654 Normal good /* Stopped because of OD mismatch */ Run # 1655 Normal good /* Normal Stop for DAQ software upgrade */ Run # 1656 Normal good /* Stopped because OD efficiency dropped to 85% */ Run # 1657 Normal good /* Stopped because of poor OD efficiency CHECK SUM at 15:09 */ Run # 1658 Normal good /* Halted by power failure with no Run summary */ Run # 1659 Normal bad /* No data OD busy Hut 2 */ Run # 1660 Normal bad /* No data OD busy Hut 2 */ Run # 1661 Normal bad /* No data */ Run # 1662 Normal good /* Normal Stop at offline request */ Run # 1663 Normal bad /* No data */ Run # 1664 Normal bad /* doubtful Run because got OD data but no OD trigger OD trigger NIM BIN power supply off */ Run # 1665 Normal bad Run # 1666 Normal bad /* No data */ Run # 1667 Normal bad /* doubtful Run because of OD trigger problems. Stopped when OD died */ Run # 1668 Normal bad /* OD dead */ Run # 1669 Normal bad /* OD dead */ Run # 1670 Normal bad /* No OD data (FSCC power, Hut 4 down) */ Run # 1671 Normal good /* Stopped because OD busy Hut 4 */ Run # 1672 Normal bad /* OD busy Hut 2 */ Run # 1673 Normal bad /* OD busy all Huts */ Run # 1674 Normal bad /* No OD data */ Run # 1675 Normal bad /* No OD data (Hut 4 busy) */ Run # 1676 Normal bad /* No OD data (Hut 4 busy) */ Run # 1677 Normal bad /* No OD data. Stopped , no free space in NOVA */ Run # 1678 Normal good /* Stopped because antisender died */ Run # 1679 Normal good /* Stopped because of OD data mismatch Run # 1680 Normal bad /* No OD data */ Run # 1681 Normal good /* Normal Stop at offline request */ Run # 1682 Normal good /* Normal Stop at offline request At 00:00 OD HV trip reset at Hut 2 Ch 14 At 02:20 CHECK SUM error At 05:00 OD HV trips discovered in Hut 2 Ch 00, 04, and 14 00 and 14 were reset After pin 2-1-5-6 was pulled 04 was also reset */ Run # 1683 Normal good /* Normal Stop at offline request */ Run # 1684 Normal bad /* No data */ Run # 1685 Normal good /* Normal Stop to prepare for Ni calibration */ Run # 1686 Normal bad /* No data Sukon9 timed out */ Run # 1687 Normal bad /* Test of DAQ */ Run # 1688 Ni good /* z = -12 */ Run # 1689 Ni good /* z = 0 */ Run # 1690 Ni good /* z = 12 */ Run # 1691 Ni bad /* z = -12, gain half */ Run # 1692 Ni good /* z = -12, gain half */ Run # 1693 Ni good /* z = 0, gain half , ATM thr = -50 */ Run # 1694 Ni good /* z = 0, gain half , ATM thr = -100 */ Run # 1695 Ni good /* z = 0, gain half , ATM thr = -80 */ Run # 1696 Laser bad /* at 0m, gain=half */ Run # 1697 Laser bad /* at 0m, gain=half, filter=1400 */ Run # 1698 Laser good /* at 0m, gain=half, filter=1350 */ Run # 1699 Normal bad /* gain half, ATM thr = -50, LE thr = 250 */ Run # 1700 Normal bad /* gain half, ATM thr = -50, LE thr = 320 */ Run # 1701 Nonexistent bad /* gain half, ATM thr = -80, LE thr = 320 */ Run # 1702 Normal bad /* gain half, ATM thr = -80, LE thr = 320 */ Run # 1703 Normal bad /* gain half, ATM thr = -50, LE thr = 320 */ Run # 1704 Normal bad /* gain half, ATM thr = -50, LE thr = 320 */ Run # 1705 Normal bad /* gain half, ATM thr = -50, LE thr = 320 */ Run # 1706 Normal good /* Normal Stop because many hex on antisorter. At 01:45 OD HV trip discovered Hut 2 channels 0.7 and 1.4 was reset. At 03:00 OD HV Hut 2 Channel 1.4 tripped and was left off. At 03:50 jumper 2-1-17-4 was pulled and Hut 2 Channel 1.4 was enabled. */ Run # 1707 Normal good /* Normal Stop. At 19:50 an OD HV trip was discovered in Hut 2 channel 0.7. At 20:00 channels 0.6 and 0.8 were also disabled. 2-1-8-9 was removed and channels 0.6 to 0.8 were enabled at 00:15. At 0:55 Hut 2 channel 0.0 was discovered tripped and enabled. At 01:30 it was discovered tripped again and enabled. *\ Run # 1708 Normal good /* Stopped because no free buffer on sukonh collector. *\ Run # 1709 Normal good /* Stopped because of invalid ATM flag. evbuild/TIMEOUT at 04:53 *\ Run # 1710 Normal bad /* Stopped because an I AM DEAD window was left over from the last run. *\ Run # 1711 Normal good /* Stopped because of OD software failure. *\ Run # 1712 Normal bad /* Stopped because no antidata. *\ Run # 1713 Normal good /* Normal Stop to replace ATM module. *\ Run # 1714 Normal good /* Event mismatch last 15 minutes (last two subruns probably bad). *\ Run # 1715 Normal good /* Event mismatch last 6000 events (last subrun probably bad). *\ Run # 1716 Normal good Run # 1717 Normal good /* Stopped because of evbuild/TIMEOUT */ Run # 1718 Normal good /* Normal stop for DAQ maintenance. */ Run # 1719 Normal bad /* No anti-data. */ Run # 1720 Normal good /* Stopped because no anti-data. OD HV 1-12-2 was off for the entire run. Cable # 10843 was identified as a flasher and disconnected. */ Run # 1721 Normal good /* OD HV 1-12-2 was off for the first part of the run. */ Run # 1722 Normal good /* Stopped because of antisorter hex dump. */ Run # 1723 Normal good /* Stopped because of antisorter hex dump. At 17:10 OD HV Hut 2 Channel 0.11 was discovered tripped and reset. */ Run # 1724 Normal good /* Stopped because eventbuilder stopped. */ Run # 1725 Normal good /* Stopped because of antisorter hex dump. */ Run # 1726 Normal good /* Normal stop to disconnect ID # 10850. */ Run # 1727 Nonexistent bad Run # 1728 Normal good /* Normal stop to remove flashers 1-8-19-2 (# 1275) and 1-10-12-1 (# 1679). */ Run # 1729 Normal good /* Stopped because of evbuild/TIMEOUT. */ Run # 1730 Nonexistent bad Run # 1731 Nonexistent bad Run # 1732 Nonexistent bad Run # 1733 Normal bad /* HV in HV crate was off from the beginning. Stopped because of sukon1 and sukon5 errors. */ Run # 1734 Normal good /* OD Hut 4 was busy for the first 3000 events. This only means the first subrun was bad if those 3000 events were written. OD HV Hut 2 channel 0.0 was discovered tripped and reset at 20:35. */ Run # 1735 Normal bad /* No OD data. */ Run # 1736 Normal good /* Stopped because of antisorter hex dump. */ Run # 1737 Normal good /* Normal stop to check ID high voltage. At 10:35 and 10:45 Hut 2 Channel 0.11 trip was reset. At 10:50 Hut 2 Channel 0.0 tripped and 2-1-1-9 was disabled. */ Run # 1738 Normal good /* Stopped because low energy reduction process stopped. */ Run # 1739 Nonexistent bad Run # 1740 Normal good /* Stopped because of antisorter hex dump. */ Run # 1741 Normal bad /* Antisorter hex dump. */ Run # 1742 Normal good /* FSCC Hut 3 internal word count wrong. */ Run # 1743 Normal good /* Bad GPS time at end. */ Run # 1744 Normal good /* Bad GPS time throughout run. */ Run # 1745 Normal good /* Stopped because of antisorter hex dump. GPS connection irregular. */ Run # 1746 Normal good /* Stopped because of antisorter hex dump. GPS connection irregular. */ Run # 1747 Normal good /* Stopped because of antisorter hex dump. GPS connection irregular. */ Run # 1748 Normal good /* Stopped because of antisorter hex dump. GPS connection irregular. */ Run # 1749 Normal good /* Stopped because of ATM error. GONG count error. */ Run # 1750 Normal good /* Stopped because of antisorter hex. At 12:00 OD HV tripped Hut 4, channel 0.3. */ Run # 1751 Normal good /* Stopped because of OFFLINE request. At 13:45 arcing was removed from OD HV 2-2-19-2 by rearranging cards.Sukonh evbuild errors at 20:14. */ Run # 1752 Normal good /* Stopped because of OFFLINE request. At 10:39 OD HV Hut 2 Channel 3.2 trip was enabled. At 13:52 OD HV 2-2-19-2 was removed. */ Run # 1753 Normal good /* Stopped because of OD DAQ problems. */ Run # 1754 Nonexistent bad Run # 1755 Normal good /* OTHERFLAG at 21:02. FSCC read error at 22:10. */ Run # 1756 Normal good /* Stopped because of OFFLINE request. GPS errors at 22:24 fixed. */ Run # 1757 Normal good /* Normal stop to test new version of SKIM. */ Run # 1758 Normal good /* Normal stop */ Run # 1759 Normal good /* Normal stop */ Run # 1760 Normal good /* Normal stop */ Run # 1761 Normal good /* Stopped because of antisorter hex dump. Occasional GPS errors. */ Run # 1762 Normal bad /* No OD data. */ Run # 1763 Normal good /* Stopped because of antisorter hex dump. */ Run # 1764 Normal good /* Stopped because of sukon1 sorter error. */ Run # 1765 Normal bad /* Antisorter hex dump. */ Run # 1766 Normal good /* Stopped because of ID DAQ error. */ Run # 1767 Normal good /* Stopped because of TKO power crash. GPS error at 20:19. */ Run # 1768 Normal bad /* No OD data. Reset FSCC Hut 1 at 20:50. */ Run # 1769 Normal good /* Stopped because of OFFLINE request. */ Run # 1770 Normal good /* Stopped because ofto do Ni calibration. */ Run # 1771 Ni good /* (35,-1626,-1170) Logbook says run summary z is wrong. */ Run # 1772 Ni good /* (35,-1626,-1200) sukon5 GONG 27,28,29,30 at 12:50 and continues to have problems. */ Run # 1773 Ni good /* (35,-1626,0) */ Run # 1774 Ni good /* (35,-1626,1200) */ Run # 1775 Ni good /* (35,-1555,1600) Logbook says run summary y is wrong. */ Run # 1776 Ni bad /* (35,-1202,-1200) Sukon3 sorter error. */ Run # 1777 Nonexistent bad Run # 1778 Nonexistent bad Run # 1779 Ni good /* (35,-1202,-1200) */ Run # 1780 Ni good /* (35,-1202,0) */ Run # 1781 Ni bad /* (35,-1202,1200) Senders stopped working.*/ Run # 1782 Ni bad /* (35,-1202,-1200) */ Run # 1783 Ni bad /* (35,-1202,-1200) evbuild/TIMEOUT */ Run # 1784 Ni good /* (35,-1202,-1200) */ Run # 1785 Ni bad /* (35,-71,-1200) */ Run # 1786 Ni bad /* (35,-71,-1200) */ Run # 1787 Ni good /* (35,-71,-1200) */ Run # 1788 Ni good /* (35,-71,0) */ Run # 1789 Ni bad /* (35,-71,1200) evbuild/TIMEOUT */ Run # 1790 Ni bad /* (35,-71,1200) sender errors */ Run # 1791 Ni good /* (35,-71,1200) */ Run # 1792 Ni+Cf good /* (35,-71,0) */ Run # 1793 Cf good /* (35,-71,0) */ Run # 1794 Ni good /* No source. */ Run # 1795 Normal good /* Stopped because of no OD data */ Run # 1796 Nonexistent bad Run # 1797 Normal bad /* Test run with no OD data. */ Run # 1798 Normal bad /* Test run at high rate. OD buffer changed from 256 to 32 (restored next run) */ Run # 1799 Normal good /* Normal stop at OFFLINE request. */ Run # 1800 Normal good /* Normal stop at OFFLINE request. */ Run # 1801 Normal bad /* Anticollector did not work. */ Run # 1802 Normal good /* Run summary lost in sukonh reboot. */ Run # 1803 Normal good /* Normal stop at OFFLINE request. */ Run # 1804 Normal good /* Run summary lost in sukonh reboot. At 12:50 OD HV trip discovered at 4-2-19, current high */ Run # 1805 Normal bad /* OD busy Hut 1 reset but continued OD problems. */ Run # 1806 Normal good /* Normal stop for new patch for sukonh. */ Run # 1807 Normal good /* Stopped because of antiheader only. */ Run # 1808 Normal good /* Stopped because of antiheader only. Evbuild error at 00:45. At 04:30 enabled OD HV. Accidental laser flash near end of run results in trigger jump. */ Run # 1809 Normal good /* Stopped because can't enable OD HV Hut 2, Channel 2.9, which was enabled after trips at 5:30, 6:00, 6:20, 7:35 and 7:45. Trip disappeared after run halted! */ Run # 1810 Normal good /* Stopped because of OD HV Hut 2, Ch 2.9. Disabled 2-2-14-1. */ Run # 1811 Normal good /* OD HV Hut 2 channels 2.7 to 2.11 off */ Run # 1812 Nonexistent bad Run # 1813 Normal good /* Normal stop. OD HV trip, Hut 2. */ Run # 1814 Normal good /* Stopped because of antiheader only. */ Run # 1815 Normal good /* OD performance at 60% */ Run # 1816 Normal good /* Normal stop at OFFLINE request. At 6:45 and earlier OD HV Hut 3, channel 1.1 tripped. Also earlier, OD HV Hut 3, Channel 1.7 tripped (reset). At 9:40 OD HV 1-1-3 was left disabled. */ Run # 1817 Normal good /* Stopped to change HV board. HV#37 error started at 12:00 resulting in no hits on cards 4-1-9 and 4-1-10. */ Run # 1818 Normal bad /* Anti DAQ dead. */ Run # 1819 Normal good /* Stopped because of sukon6 error. SN SK10-025 may have been broken for several days. Replaced at end of run. */ Run # 1820 Normal good /* Normal stop to prepare laser runs. */ Run # 1821 Laser good /* Filter 1450 */ Run # 1822 Laser good /* Filter 1400 */ Run # 1823 Laser good /* Filter 1350 */ Run # 1824 Laser good /* Filter 1300 */ Run # 1825 Laser good /* Filter 1250 */ Run # 1826 Laser good /* Filter 1200 */ Run # 1827 Laser good /* Filter 1150 */ Run # 1828 Laser good /* Filter 1100 */ Run # 1829 Laser good /* Filter 1050 */ Run # 1830 Laser good /* Filter 1000 */ Run # 1831 Laser good /* Filter 950 */ Run # 1832 Laser good /* Filter 900 */ Run # 1833 Laser good /* Filter 850 */ Run # 1834 Laser good /* Filter 800 */ Run # 1835 Laser good /* Filter 750 */ Run # 1836 Laser good /* Filter 700 */ Run # 1837 Laser good /* Filter 650 */ Run # 1838 Laser good /* Filter 600 */ Run # 1839 Laser good /* Filter 550 */ Run # 1840 Laser good /* Filter 500 */ Run # 1841 Laser good /* Filter 450 */ Run # 1842 Laser good /* Filter 300 */ Run # 1843 Laser good /* Filter 1450, z = 50 */ Run # 1844 Laser good /* Filter 300, z = 50 */ Run # 1845 Laser bad /* Anti-laser timing run, 500 shots each fiber, no OD data */ Run # 1846 Laser bad /* Anti-laser timing run, 500 shots each fiber, no OD data. Hut 2 out of synch. Pulled OD HV 1-1-3-5 at end of run. */ Run # 1847 Laser bad /* Anti-laser timing run, 500 shots each fiber, filter 1100 */ Run # 1848 Normal good /* Normal stop at OFFLINE request. */ Run # 1849 Nonexistent bad Run # 1850 Normal good /* Run summary lost on sukonh crash and reboot. */ Run # 1851 Normal good /* Stopped because of sukon7 serial count error at 15:03. */ Run # 1852 Nonexistent bad Run # 1853 Normal bad /* OD busy Hut 1, FSCC read error. */ Run # 1854 Normal good /* Stopped because of no data in OD Hut 1. At 00:40 OD HV Hut 4-2-19 tripped twice, pin 4-2-19-9 removed. */ Run # 1855 Normal bad /* Stopped because SKIM dead. */ Run # 1856 Nonexistent bad Run # 1857 Normal good /* Stopped because of only anti HEADER. */ Run # 1858 Nonexistent bad Run # 1859 Normal good /* Normal stop at OFFLINE request. */ Run # 1860 Nonexistent bad Run # 1861 Normal good /* Stopped because of no OD data. */ Run # 1862 Nonexistent bad Run # 1863 Normal bad /* OD busy Hut 2 */ Run # 1864 Nonexistent bad Run # 1865 Normal good /* Stopped because of OD TDC buffer mismatch. */ Run # 1866 Normal good /* Stopped because of no OD data. */ Run # 1867 Normal good /* Run summary lost on sukonh reboot. */ Run # 1868 Normal good /* Normal stop to take OD pedestals. */ Run # 1869 Normal bad /* OD pedestal run */ Run # 1870 Normal good /* Stopped because of no OD data from Hut 4. */ Run # 1871 Normal good /* Stopped because ofcentral hut OD FIFO busy. */ Run # 1872 Normal bad /* OD Hut 1 mismatch. */ Run # 1873 Normal good /* Stopped because of sukon 1,3,7 errors. */ Run # 1874 Normal good /* Stopped because no OD data, Hut 4, event # mismatch. */ Run # 1875 Normal good /* Run summary lost on sukon2 hangup-reboot. Stopped on sukonh evbuild/TIMEOUT*/ Run # 1876 Normal good /* Run summary lost. Stopped because of collector no buffer. */ Run # 1877 Normal bad /* Anti mismatch. */ Run # 1878 Normal good /* Stopped because of evbuild/TIMEOUT. */ Run # 1879 Normal good /* Stopped because of OD Hut 4 no data. At 18:00 Hut 4-2-13 was disabled until 19:15. At oo:38 4-2-13-6 identified as a flasher was disconnected. At 00:55 Hut channel 1.1 discovered tripped was enabled. */ Run # 1880 Normal good /* Stopped because of OD Hut 1 mismatch. */ Run # 1881 Normal good /* Stopped because of OD Hut 2 mismatch. */ Run # 1882 Normal good /* Stopped because of only anti HEADER. */ Run # 1883 Normal good /* Stopped because of only anti HEADER. */ Run # 1884 Nonexistent bad Run # 1885 Normal good /* Stopped because of only anti HEADER. */ Run # 1886 Normal good /* Normal stop to improve anti-online code. */ Run # 1887 Normal good /* Stopped because of only anti rollover error. */ Run # 1888 Normal good /* Stopped because of no matching event, Hut 4 */ Run # 1889 Normal good /* Stopped because of only anti HEADER. */ Run # 1890 Normal good /* Normal stop to work on trigger system. */ Run # 1891 Normal bad /* Sukante has no data. */ Run # 1892 Normal good /* Stopped because of OD FIFO busy. */ Run # 1893 Normal bad /* Only anti HEADER */ Run # 1894 Normal good /* Stopped because of DAQ error. Hut 1 TDC/latch mismatch at 02:25 */ Run # 1895 Normal good /* Stopped because of only anti HEADER. Run summary was lost. */ Run # 1896 Normal good /* Run summary lost on sukon1 error and reboot. */ Run # 1897 Normal good /* Stopped because of evbuild/TIMEOUT. */ Run # 1898 Nonexistent bad Run # 1899 Normal bad /* No OD data. FSCC monitor 4 on. */ Run # 1900 Normal bad /* No OD data. FSCC monitor 4 on. */ Run # 1901 Normal bad /* No OD data. FSCC monitor 4 on. */ Run # 1902 Normal bad /* No OD data. FSCC monitor 4 on. */ Run # 1903 Nonexistent bad Run # 1904 Normal bad /* No OD data. FSCC monitor 4 on. */ Run # 1905 Normal bad /* No OD data. FSCC monitor 4 on. */ Run # 1906 Normal bad /* OD not on, BIP card in Hut 4 replaced at end of run. */ Run # 1907 Normal good /* Stopped because of power failure. */ Run # 1908 Normal good /* Normal stop requested by OFFLINE */ Run # 1909 Normal good /* Run summary lost in lightening strike. */ Run # 1910 Normal bad /* No OD data. FSCC monitor 3 on. */ Run # 1911 Normal bad /* No OD data. FSCC monitor 3 on. */ Run # 1912 Normal bad /* No OD data. FSCC monitor 3 on. */ Run # 1913 Normal bad /* No OD data. FSCC monitor 3 on. */ Run # 1914 Normal good /* Normal stop at OFFLINE request. */ Run # 1915 Normal good /* Stopped because no OD data, Hut 4. */ Run # 1916 Normal good /* Stopped because no OD data. */ Run # 1917 Normal good /* Kingfish called this 1918 because of operator error. */ Run # 1918 Nonexistent bad Run # 1919 Normal good /* Stopped because no OD data. */ Run # 1920 Normal good /* Stopped because no OD data. */ Run # 1921 Normal good /* Stopped because no OD data. */ Run # 1922 Normal good /* Normal stop to change FDDI board. OD HV Hut 2 , channel 2.11 tripped, reset. */ Run # 1923 Normal good /* OD HV Hut 2 , channel 2.11 tripped, reset. */ Run # 1924 Normal good /* OD HV Hut 2 , channel 2.11 tripped, reset. */ Run # 1925 Normal good /* No run summary because of sukonh reboot. OD HV Hut 2 , channel 2.11 tripped, reset. */ Run # 1926 Normal good Run # 1927 Normal good /* Ended on abnormal ATM flag. OD HV 2-2-16 reset after trip, 02:20. */ Run # 1928 Normal bad /* Stopped for anticollector stack */ Run # 1929 Normal good /* stopped because disk/export/online3 is full and cannot write. Halt was followed by a sukonh disk crash */ Run # 1930 Normal bad /* No OD data */ Run # 1931 Normal bad /* No OD data */ Run # 1932 Normal bad /* No OD data */ Run # 1933 Normal good /* GPS error at 12:45, jiggled and fixed */ Run # 1934 Normal bad /* Test of low E trigger at 300 mV */ Run # 1935 Normal bad /* Test of low E trigger at 300 mV */ Run # 1936 Normal bad /* Test of low E trigger at 290 mV */ Run # 1937 Normal bad /* Test of low E trigger at 296 mV */ Run # 1938 Normal good /* Stopped because of Hut 3 FCC read error */ Run # 1939 Normal good /* Stopped because of no anticounter data */ Run # 1940 Normal good Run # 1941 Normal good /* Stopped because of no anticounter data */ Run # 1942 Normal good /* Normal stop at OFFLINE request */ Run # 1943 Normal good Run # 1944 Normal good Run # 1945 Normal good /* Stopped because of no OD data */ Run # 1946 Normal good Run # 1947 Normal bad /* Test with ID off. */ Run # 1948 Normal bad /* Test with ID off. OD HV reduced 100 V for all tubes. */ Run # 1949 Normal bad /* Test with ID off. OD HV reduced 200 V for all tubes. */ Run # 1950 Normal bad /* Test with ID on. OD HV reduced 200 V for all tubes. */ Run # 1951 Normal bad /* Test with ID on. OD HV reduced 100 V for all tubes. */ Run # 1952 Normal bad /* Test with ID on. OD HV reduced 100 V for all tubes. At 01:40 discovered OD HV Hut 4 Ch 1.6 ribbon not pushed all the way in. Corrected. At 01:45 problems discovered in QTC 2.5, Hut 4. Run stopped to replace with QTC spare. */ Run # 1953 Normal good /* Stopped because of only anti HEADER */ Run # 1954 Normal good /* Stopped because of only anti HEADER */ Run # 1955 Normal good /* Stopped because of only anti HEADER */ Run # 1956 Normal good /* Stopped because of only anti HEADER */ Run # 1957 Normal good /* Stopped because of only anti HEADER */ Run # 1958 Normal good /* Stopped because of only anti HEADER */ Run # 1959 Normal good /* Normal stop to replace QTC card */ Run # 1960 Normal good /* Stopped because of only anti HEADER */ Run # 1961 Nonexistent bad Run # 1962 Normal good /* Run summary lost, stopped because skim@kingfish dead */ Run # 1963 Normal good /* Stopped because sukon2 not working */ Run # 1964 Normal good /* Normal stop. At 18:00 OD HV trip Hut 1, Ch 2.9 enabled. At end of run 2-2-14-1 removed and ID cable #2312 revived and #2311 switched off. */ Run # 1965 Normal good /* Normal stop. At 22:00 OD HV trip Hut 4, Ch 0.6. 4-1-7-4 was removed after run. */ Run # 1966 Normal good /* Stopped because of only anti HEADER */ Run # 1967 Normal good /* Stopped because of only anti HEADER */ Run # 1968 Normal good /* Normal stop. */ Run # 1969 Normal good /* Run summay lost because sukonh crashed. Jumper 2-1-6-7 removed at end of run as suspected flasher. */ Run # 1970 Normal good /* Normal stop to connect cable #2311 and #2261. At 07:35 OD HV trip discovered in Hut 1, Channel 1.0. 1-1-13-9 removed. During the evening shift, which runs through Run 1974, extensive tube testing was done on the following tubes at unspecified times, involving disabling and enabling of associated and nearby cards: 4-1-4-2, 4-1-7-4, 4-1-17-5, 3-1-11-10, 2-1-5-6, 2-1-1-9, 2-1-8-9, 2-1-17-4, 2-1-13-9, 1-1-3-5. It is conceivable these were all done during bad run # 1973, which would make this run and 1974 completely good. */ Run # 1971 Normal bad /* Stop FIFO busy */ Run # 1972 Normal bad /* Abort no msgsrv running */ Run # 1973 Normal bad /* Trigger rate histograms show lower trigger rate throughout the run. Characterized as junk by operators. */ Run # 1974 Normal good /* Stopped because of apparent sukon error. CPU times in sorter and sender negative. */ Run # 1975 Normal good /* Stopped because of OD mismatch. */ Run # 1976 Normal good /* Stopped because of sukon high rate */ Run # 1977 Normal good /* Normal stop requested by OFFLINE */ Run # 1978 Normal good /* Stopped because of only anti HEADER */ Run # 1979 Normal bad /* Aborted because of NOVA trouble */ Run # 1980 Normal good /* Normal stop to start Ni calibration */ Run # 1981 Ni good /* (35.3,-70.7,0) with fission trigger */ Run # 1982 Ni good /* (35.3,-70.7,-1200) with fission trigger */ Run # 1983 Ni good /* Logbook says (35.3,-70.7,12) with fission trigger but must mean z = 1200 */ Run # 1984 Ni good /* (35.3,-70.7,1600) with fission trigger */ Run # 1985 Normal bad /* No OD data */ Run # 1986 Normal good /* Stopped because of OD TDC buffer mismatch. OD HV trips in Hut 4-1-4 and unrecorded cards in Hut 2 and 3 (enabled) but 4-1-4-12 removed. */ Run # 1987 Normal good /* Stopped because of OD TDC buffer mismatch. At 5:20 OD HV Hut 3-1-11 trips were reset. */ Run # 1988 Normal good /* Stopped because of FIFO busy. Run summary destroyed. OD HV trips Hut 1, ch 2.3; Hut 2, ch 0.4; Hut 3, ch 0.10. Pins removed from 2-1-5-6 and 3-1-11-10. */ Run # 1989 Normal bad /* No OD data */ Run # 1990 Normal good /* Stopped because of no OD data */ Run # 1991 Normal good /* Halted by sukonh crash and reboot. */ Run # 1992 Normal good /* Stopped because of only anti HEADER */ Run # 1993 Normal good /* Normal stop to apply patch on sukonh */ Run # 1994 Normal good /* Stopped because of no OD data */ Run # 1995 Normal good /* Normal stop requested by OFFLINE */ Run # 1996 Normal good /* Stopped because of only anti HEADER */ Run # 1997 Normal good /* Normal stop for Xe calibration. */ Run # 1998 Xe good Run # 1999 Xe good Run # 2000 Xe good Run # 2001 Xe good Run # 2002 Xe good Run # 2003 Xe good Run # 2004 Xe good Run # 2005 Xe good Run # 2006 Xe good Run # 2007 Xe good Run # 2008 Xe good Run # 2009 Xe good Run # 2010 Xe good Run # 2011 Xe good Run # 2012 Normal bad /* OD HV off */ Run # 2013 Normal good /* Stopped because of OD Hut 2 TDC buffer mismatch */ Run # 2014 Nonexistent bad Run # 2015 Normal good /* Stopped because no OD */ Run # 2016 Normal good /* Normal stop to allow check of online monitor. At 00:30 OD HV Hut 3, Ch 0.0 was discovered tripped and enabled. */ Run # 2017 Normal bad /* Test run */ Run # 2018 Normal bad /* Test run */ Run # 2019 Normal good /* Stopped because no OD */ Run # 2020 Normal good /* 05:15 OD HV rip Hut 3, Ch0.11. Disabled Hut 3 Ch 0.10,0.11, and 1.0 and removed 3-1-12-3 during run. */ Run # 2021 Normal good /* Normal stop requested by OFFLINE */ Run # 2022 Normal good /* Stopped because of only anti HEADER. OD HV trips Hut 3, Ch 0.11 and Hut 1, ch 0.0 enabled during run. */ Run # 2023 Normal good /* Stopped because of only anti HEADER. */ Run # 2024 Normal good /* Stopped because of sukonh error (ev.builder) */ Run # 2025 Normal good /* Normal stop to unplug OD PMT. At 0:55 OD HV trips in Hut 2, ch 0.0; Hut 3, ch 0.11; Hut 3, ch 1.1 were enabled. At 0:08 Hut 2, ch 0.0 tripped again and several attempts to enable failed. At end of run jumper was removed for 2-1-1-9. */ Run # 2026 Normal good /* Stopped because of only anti HEADER. */ Run # 2027 Normal good /* Stopped because of only anti HEADER. At 05:40 a trip in OD HV Hut 3, Ch 1.4 was enabled. */ Run # 2028 Normal bad /* No OD data */ Run # 2029 Normal good /* Stopped because of only anti HEADER. */ Run # 2030 Nonexistent bad Run # 2031 Normal good /* Stopped because of invalid ATM flag */ Run # 2032 Normal good /* Stopped because of kingfish error. */ Run # 2033 Normal bad /* Stopped because of only anti HEADER. */ Run # 2034 Normal good /* Includes LINAC after 23:00 */ Run # 2035 Normal bad /* Includes LINAC. Otherwise good. Normal stop. */ Run # 2036 Normal bad /* FIFO busy */ Run # 2037 Normal good /* Stopped because of only anti HEADER. */ Run # 2038 Normal bad /* Stopped because of FIFO busy */ Run # 2039 Normal bad /* Stopped because of only anti HEADER. */ Run # 2040 Normal bad /* Hut 2 busy */ Run # 2041 Normal bad /* FIFO busy */ Run # 2042 Normal good /* Stopped to allow OD-DAQ testing */ Run # 2043 Normal good /* Normal stop at offline request. At 01:12 OD HV trip Hut 3, ch 1.4 enabled. */ Run # 2044 Normal good /* Stopped because of sukon::sorter/INVALID MAI or SAI detected */ Run # 2045 Normal good /* Normal stop at offline request. */ Run # 2046 Normal good /* Run summary lost in sukonh crash. Count error in GONG-25 at 03:20. At 01:09 OD HV trip discovered Hut 4, ch 3.0, successfully enabled at 02:20 resulting in spike in trigger rate. */ Run # 2047 Normal good /* Normal stop to start cross talk test. */ Run # 2048 Normal bad /* only anti HEADER */ Run # 2049 Normal bad /* Hut 3 FASTBUS busy error */ Run # 2050 Normal bad /* FIFO busy error */ Run # 2051 Normal bad /* Cross talk check, QTC thresholds changed during run. */ Run # 2052 Normal bad /* QTC threshold -20 mV, OD HV reduced -100 V */ Run # 2053 Normal good /* Run summary lost in sukonh crash. */ Run # 2054 Normal bad /* no anti-counter data */ Run # 2055 Normal good /* Normal stop to change HV boards */ Run # 2056 Normal bad /* Sukonh crash */ Run # 2057 Normal bad /* Test run for ONLINE */ Run # 2058 Normal bad /* Test run for ONLINE */ Run # 2059 Normal good /* Stopped because of only anti HEADER */ Run # 2060 Nonexistent bad Run # 2061 Normal good /* No events on display at 23:30 */ Run # 2062 Normal bad /* Hut 2 busy */ Run # 2063 Normal good /* Stopped because of only anti HEADER */ Run # 2064 Normal good /* Stopped because of no OD data */ Run # 2065 Normal good /* Stopped because of power outage at 12:55 */ Run # 2066 Normal bad /* Hut 3 FASTBUS error */ Run # 2067 Normal bad /* Hut 3 and 4 FASTBUS error */ Run # 2068 Normal bad /* Test run */ Run # 2069 Normal bad /* Test run, no anti-data */ Run # 2070 Normal good /* Stopped because of no OD data */ Run # 2071 Normal good /* Normal stop at OFFLINE request */ Run # 2072 Normal good /* Stopped because of no OD data */ Run # 2073 Normal good /* Stopped because of no OD data */ Run # 2074 Nonexistent bad Run # 2075 Normal bad /* no OD */ Run # 2076 Normal good /* Stopped because of no OD data */ Run # 2077 Normal good /* Stopped because of no OD data */ Run # 2078 Normal good /* Stopped because of no OD data */ Run # 2079 Normal good /* Stopped because of no OD data */ Run # 2080 Normal bad /* FIFO busy */ Run # 2081 Normal good /* Stopped because of no OD data */ Run # 2082 Normal good /* Stopped because of no OD data */ Run # 2083 Normal good /* Stopped because of no OD data */ Run # 2084 Normal good /* Stopped because of no OD data */ Run # 2085 Normal good /* Stopped because of no OD data */ Run # 2086 Normal bad /* Test run LE thr=258/OD always on */ Run # 2087 Normal bad /* Test run LE thr=248/OD always on. Sukonh crash. */ Run # 2088 Normal bad /* Test run LE thr=248/OD always on. Sorter on sukon2 stopped. */ Run # 2089 Normal bad /* Test run LE thr=248/OD always on */ Run # 2090 Normal bad /* Test run LE thr=248/OD only HE & OD */ Run # 2091 Normal bad /* Test run LE thr=248/OD only HE & OD */ Run # 2092 Nonexistent bad Run # 2093 Nonexistent bad Run # 2094 Ni good /* 130 mV. Stopped because no OD */ Run # 2095 Ni bad /* 130 mV */ Run # 2096 Nonexistent bad Run # 2097 Ni good /* 130 mV. */ Run # 2098 Nonexistent bad Run # 2099 Ni good /* 100 mV. */ Run # 2100 Ni good /* 110 mV. */ Run # 2101 Normal good /* Normal stop at OFFLINE request */ Run # 2102 Normal bad /* No OD */ Run # 2103 Normal bad /* Hut 2 busy */ Run # 2104 Normal good /* Normal stop to insert new anti-program */ Run # 2105 Normal good /* Stopped because sukonh 6e error */ Run # 2106 Normal good /* Stopped because no OD */ Run # 2107 Normal good /* Normal stop to change ATM */ Run # 2108 Nonexistent bad Run # 2109 Normal good /* Normal stop at OFFLINE request */ Run # 2110 Nonexistent bad Run # 2111 Normal good /* Normal stop to unplug high rate PMT #10657 */ Run # 2112 Normal good /* Stopped because sukonh2e error */ Run # 2113 Normal bad /* Run summary lost on cleanup. Netserve dead */ Run # 2114 Normal good /* Normal stop at OFFLINE request */ Run # 2115 Normal bad /* no OD */ Run # 2116 Normal good /* Normal stop for system change. For subsequent runs the LIME veto was "OR"ed with the 30 microsec gate from the LINAC pickup signal. */ Run # 2117 Normal bad /* no OD */ Run # 2118 Normal good /* Stopped because no TDC on anti */ Run # 2119 Normal good /* Stopped because no anti-data */ Run # 2120 Normal good /* Stopped because no OD */ Run # 2121 Normal bad /* no OD */ Run # 2122 Normal bad Run # 2123 Normal good /* Stopped because no OD */ Run # 2124 Normal bad /* no OD */ Run # 2125 Normal bad /* no OD */ Run # 2126 Normal good /* Stopped because of sukonh3e error */ Run # 2127 Normal good /* Stopped because no OD */ Run # 2128 Nonexistent bad Run # 2129 Normal bad /* no OD */ Run # 2130 Nonexistent bad Run # 2131 Normal good /* Stopped because no OD */ Run # 2132 Normal good /* Stopped because no OD */ Run # 2133 Normal good /* Stopped because sukon4e sorter stopped */ Run # 2134 Normal good /* Stopped because no ID on SCAN. msgcnt does not exist at 03:25 */ Run # 2135 Normal good /* Stopped because of sukon0 bus error */ Run # 2136 Normal good /* Stopped because noisey */ Run # 2137 Normal good /* Sorter stopped */ Run # 2138 Normal good /* Normal stop to start Ni calibration */ Run # 2139 Ni bad /* z = -12 m, sukant not off */ Run # 2140 Ni good /* z = -12 m */ Run # 2141 Ni good /* z = 0 m */ Run # 2142 Ni good /* z = 12 m */ Run # 2143 Ni good /* z = 16 m */ Run # 2144 Normal good /* GONG invalid flag at 14:25. Stopped at 14:42 because ATM in Hut 3 crate 6 is dead */ Run # 2145 Normal good /* Stopped because pmonitor/collector dead on sukon6 */ Run # 2146 Normal good /* Stopped because no antidata */ Run # 2147 Normal good /* Stopped because only anti HEADER */ Run # 2148 Normal good /* Normal stop at OFFLINE request */ Run # 2149 Nonexistent bad Run # 2150 Normal good /* Stopped because only anti HEADER */ Run # 2151 Normal good /* There are two runs with this number. The run summary of the first and longer version was lost */ Run # 2152 Normal good /* Normal stop because cable #10657 gave high rate */ Run # 2153 Normal bad /* HV error. hv_on executed after run */ Run # 2154 Normal bad /* FIFO busy */ Run # 2155 Normal good /* Normal stop at OFFLINE request */ Run # 2156 Normal bad /* Stopped because sorter@sukon2 & sukon9 were dead. */ Run # 2157 Normal good /* Stopped because no ID data on SCAN at 4:16 */ Run # 2158 Normal good /* Stopped to enable OD card after HV trip */ Run # 2159 Normal bad /* sukon problem */ Run # 2160 Normal good /* Stopped because collector dead on sukante */ Run # 2161 Normal bad /* No data taken on kingfish throughout run */ Run # 2162 Normal bad /* No data taken on kingfish throughout run */ Run # 2163 Normal good /* Normal stop requested by OFFLINE */ Run # 2164 Normal good /* Stopped because FIFO busy */ Run # 2165 Normal good /* Normal stop requested by OFFLINE */ Run # 2166 Normal good /* Run summary lost in sukonh crash */ Run # 2167 Normal bad Run # 2168 Normal bad /* At 22:13 slow monitor not working well, restarted by slc_monitor. At 22:18 repeated sukon1 errors */ Run # 2169 Normal bad /* FASTBUS busy, Hut 3 */ Run # 2170 Normal good /* Stopped because eventcounter:SENDER(2) has been dead */ Run # 2171 Normal bad /* FASTBUS busy, Hut 2 */ Run # 2172 Normal bad /* FIFO busy */ Run # 2173 Normal bad /* Sender time out */ Run # 2174 Normal bad /* Test run */ Run # 2175 Nonexistent bad Run # 2176 Normal good /* Stopped because of only anti HEADER */ Run # 2177 Normal good /* Stopped because of only anti HEADER. Run summary lost in cleanup after run. */ Run # 2178 Normal bad /* Sukon1 and sukon2 did not run */ Run # 2179 Normal good /* Stopped because of only anti HEADER */ Run # 2180 Normal good /* Stopped because there is no msgctl */ Run # 2181 Normal good /* Stopped because of many anticollector errors. */ Run # 2182 Normal good /* Stopped automatically, perhaps due to sukon1 dead */ Run # 2183 Normal good /* Normal stop for anti-testing */ Run # 2184 Normal bad /* Test run with no OD trigger */ Run # 2185 Normal bad /* Test run with no OD trigger */ Run # 2186 Normal bad /* Test run with no OD trigger */ Run # 2187 Nonexistent bad Run # 2188 Normal bad /* Test run with almost no OD data */ Run # 2189 Normal bad /* Test run */ Run # 2190 Normal bad /* Test run */ Run # 2191 Normal bad /* Test run */ Run # 2192 Normal bad /* Test run */ Run # 2193 Normal bad /* Test run with OD HV -100 V */ Run # 2194 Normal bad /* Test run with OD HV -100 V */ Run # 2195 Normal bad /* Test run with OD HV -100 V */ Run # 2196 Normal bad /* Test run with OD HV -100 V */ Run # 2197 Normal bad /* Run is good but OD is at -100 V */ Run # 2198 Nonexistent bad Run # 2199 Normal bad /* Test 32 microsec code 6 microsec delay at OD HV at -100 V */ Run # 2200 Normal bad /* Test 32 microsec code 10 microsec delay at OD HV at -100 V */ Run # 2201 Nonexistent bad Run # 2202 Nonexistent bad Run # 2203 Nonexistent bad Run # 2204 Laser good /* Stopped because Hut 4 busy */ Run # 2205 Nonexistent bad Run # 2206 Laser good /* Stopped because OD busy */ Run # 2207 Laser good Run # 2208 Laser good Run # 2209 Normal bad /* Run is good but OD is at -100 V. Stopped by sukonh error. */ Run # 2210 Normal good /* OD HV returned to nominal values. Stopped by sukonh error. */ Run # 2211 Normal good /* Stopped because netserve dead */ Run # 2212 Normal good /* Stopped because of sukonh eventbuild/TIMEOUT */ Run # 2213 Nonexistent bad Run # 2214 Normal good /* Events after about 62000 have no OD data */ Run # 2215 Normal good /* Normal stop to fix sukeve09's board */ Run # 2216 Nonexistent bad Run # 2217 Normal good /* Stopped because of only anti HEADER */ Run # 2218 Nonexistent bad Run # 2219 Normal good /* Stopped because of Kingfish error */ Run # 2220 Normal good /* Run summary lost in sukonh crash */ Run # 2221 Normal good /* Run summary lost in sukonh crash */ Run # 2222 Normal good /* Stopped because of Kingfish error */ Run # 2223 Normal good /* Stopped because of only anti HEADER */ Run # 2224 Normal good /* Stopped because of evbuild/add_evnt:buf_kind=ILLEGAL */ Run # 2225 Normal good /* Stopped because of only anti HEADER */ Run # 2226 Normal good /* Stopped because of only anti HEADER */ Run # 2227 Normal good /* Stopped because of only anti HEADER */ Run # 2228 Normal good /* Stopped because of only anti HEADER */ Run # 2229 Normal good /* Stopped because of only anti HEADER */ Run # 2230 Normal bad /* sukon sender errors throughout run */ Run # 2231 Normal good /* Stopped because of only anti HEADER. Run summary lost. */ Run # 2232 Normal good /* Stopped because of only anti HEADER */ Run # 2233 Normal good /* Normal stop for sukonh maintenance */ Run # 2234 Normal good /* Normal stop to enable OD HUT 3, ch 0.11 */ Run # 2235 Normal good /* Normal stop to enable tripped OD HV */ Run # 2236 Normal bad /* only anti HEADER */ Run # 2237 Normal good /* Stopped because of only anti HEADER */ Run # 2238 Normal good /* Stopped because of only anti HEADER */ Run # 2239 Normal good /* Normal stop to allow ATM plug-in */ Run # 2240 Normal bad /* Hut 4 busy */ Run # 2241 Normal good /* Stopped because of only anti HEADER */ Run # 2242 Normal good /* Stopped because of only anti HEADER */ Run # 2243 Normal good /* Stopped because of only anti HEADER */ Run # 2244 Normal good /* stopped because of gong count error, sds serial count error */ Run # 2245 Normal good /* Run summary lost in sukonh crash */ Run # 2246 Normal good /* Stopped because sorters on sukon6 and 8 were dead */ Run # 2247 Normal good /* Stopped because of only anti HEADER */ Run # 2248 Normal good /* Normal stop for OD HV maintenance */ Run # 2249 Nonexistent bad Run # 2250 Normal good /* Stopped because of only anti HEADER */ Run # 2251 Normal good /* Stopped because OD HV Hut 2, ch 2.11 was discovered to have tripped. Enabled for next run */ Run # 2252 Nonexistent bad Run # 2253 Normal good /* Stopped because of only anti HEADER */ Run # 2254 Normal good /* Stopped because of only anti HEADER */ Run # 2255 Normal good /* Normal stop to allow OD test */ Run # 2256 Nonexistent bad Run # 2257 Normal good /* Stopped because of only anti HEADER */ Run # 2258 Normal good /* Stopped because of only anti HEADER */ Run # 2259 Normal good /* Stopped because of only anti HEADER */ Run # 2260 Normal good /* Stopped because of only anti HEADER */ Run # 2261 Normal good /* Stopped because of only anti HEADER */ Run # 2262 Normal bad /* Test run to examine OD PMT HV */ Run # 2263 Normal bad /* FIFO busy */ Run # 2264 Normal good /* Stopped because of only anti HEADER */ Run # 2265 Normal good /* Stopped by sukonh auto reboot after "BAD TRAP error message. Run summary lost.*/ Run # 2266 Normal good /* Stopped by sukonh reboot. Run summary lost */ Run # 2267 Normal bad /* Sender time out, sukante collector not running */ Run # 2268 Normal bad /* Sender time out, sukante collector not running */ Run # 2269 Normal bad /* only anti HEADER */ Run # 2270 Normal good /* Normal stop to investigate OD HV trip, Hut 3, ch 0.1 discovered 8:15. */ Run # 2271 Normal bad /* only anti HEADER */ Run # 2272 Normal good /* Aborted: DAQ hangup,network down, power supply down. Run summary lost */ Run # 2273 Nonexistent bad Run # 2274 Nonexistent bad Run # 2275 Nonexistent bad Run # 2276 Nonexistent bad Run # 2277 Nonexistent bad Run # 2278 Normal good /* Normal stop to install DAT. Rebooted */ Run # 2279 Normal good /* Stopped because of sukon3 sorter sds count error */ Run # 2280 Normal good /* Stopped because sukon1e sender died */ Run # 2281 Normal good /* Stopped because only anti HEADER */ Run # 2282 Nonexistent bad Run # 2283 Ni good /* z = -12. Trigger rate half normal due to raising discriminator threshold */ Run # 2284 Ni good /* z = 0. Threshold lowered back to 29 mV */ Run # 2285 Ni good /* z = 12 */ Run # 2286 Normal good /* Stopped because no ID data */ Run # 2287 Normal good /* Stopped because only anti HEADER. One minute before run halt ID trigger rate rose to 700 Hz */ Run # 2288 Normal good /* Stopped because no OD data */ Run # 2289 Normal good /* Stopped because sorter@sukant9 died */ Run # 2290 Normal good /* Stopped because sorter@sukant9 died */ Run # 2291 Nonexistent bad Run # 2292 Normal good /* Stopped because sorter@sukant9 died */ Run # 2293 Normal good /* Stopped because sorter@sukant9 died */ Run # 2294 Normal good /* Stopped because sorter@sukant9 died */ Run # 2295 Normal good /* Stopped because sorter@sukant9 died */ Run # 2296 Normal good /* Normal stop requested by OFFLINE */ Run # 2297 Nonexistent bad Run # 2298 Nonexistent bad Run # 2299 Normal good /* Stopped because sorter@sukant9 died */ Run # 2300 Normal bad /* Stopped to reboot sukon9 */ Run # 2301 Normal good /* Stopped because sorter@sukant9 died */ Run # 2302 Normal good /* Stopped because of data send error */ Run # 2303 Normal good /* Stopped because of only anti HEADER */ Run # 2304 Normal good /* Normal stop to inspect tank */ Run # 2305 Normal bad /* msgctl did not come up properly */ Run # 2306 Normal good /* Stopped because of only anti HEADER */ Run # 2307 Normal good /* Stopped because of only anti HEADER */ Run # 2308 Normal good /* Stopped because of only anti HEADER */ Run # 2309 Normal good /* Stopped because of sukon8 errors */ Run # 2310 Normal good /* Stopped because of no OD */ Run # 2311 Normal good /* Stopped because of only anti HEADER */ Run # 2312 Normal good /* Stopped because of only anti HEADER. GPS errors 11:08 to 11:15 and again 11:17 to 11:19 */ Run # 2313 Normal good /* Stopped because of only anti HEADER. GPS error 14:27 */ Run # 2314 Normal good /* Stopped because of only anti HEADER */ Run # 2315 Normal good /* alloc:/home:file system full at 1:30. Run summary destroyed. GPS error 15:39 */ Run # 2316 Normal good /* Normal stop for OD PMT check */ Run # 2317 Normal bad /* Bad because frequent disabling of OD HV cards */ Run # 2318 Normal bad /* Bad because frequent disabling of OD HV cards */ Run # 2319 Normal good /* Stopped because of only anti HEADER */ Run # 2320 Normal good /* Stopped because of only anti HEADER */ Run # 2321 Normal good /* Stopped because sukon3 stopped */ Run # 2322 Normal good /* ATM error at 3:21. Stopped at 4:15 because alloc:/home:file system full */ Run # 2323 Normal good /* file system full at 6:30 */ Run # 2324 Normal good /* Stopped because of only anti HEADER. GONG count error 10:50 */ Run # 2325 Normal good /* Stopped because of only anti HEADER */ Run # 2326 Nonexistent bad Run # 2327 Normal good /* Stopped because of only anti HEADER */ Run # 2328 Nonexistent bad Run # 2329 Normal good /* Run summary lost in sukonh reboot */ Run # 2330 Normal good /* home@sukonh file system full. Run summary lost in sukonh reboot */ Run # 2331 Normal good /* Stopped because of only anti HEADER */ Run # 2332 Normal good /* Run summary lost in power failure */ Run # 2333 Normal good /* Normal stop for ONLINE test Run # 2334 Normal bad /* Test with LowE thr=290 */ Run # 2335 Normal bad /* Test with LowE thr=290 */ Run # 2336 Normal bad /* Test with LowE thr=290 */ Run # 2337 Normal bad /* Test with LowE thr=280 */ Run # 2338 Normal bad /* Test with LowE thr=270 */ Run # 2339 Normal bad /* Test with LowE thr=270 */ Run # 2340 Normal bad /* Test with LowE thr=270 */ Run # 2341 Normal bad /* Test with LowE thr=270 */ Run # 2342 Normal bad /* Test with LowE thr=270 */ Run # 2343 Normal bad /* Test with LowE thr=260 */ Run # 2344 Normal bad /* Test with LowE thr=260 */ Run # 2345 Normal bad /* Test with LowE thr=260 */ Run # 2346 Normal bad /* Test with LowE thr=260 */ Run # 2347 Normal bad /* Test with LowE thr=260 */ Run # 2348 Normal bad /* Test with LowE thr=260 */ Run # 2349 Normal bad /* Test with LowE thr=260 */ Run # 2350 Normal bad /* Test with LowE thr=260 */ Run # 2351 Nonexistent bad Run # 2352 Normal bad /* Test with LowE thr=260 */ Run # 2353 Normal bad /* Test with LowE thr=260 */ Run # 2354 Normal bad /* Test with LowE thr=260 */ Run # 2355 Normal bad /* Test with LowE thr=260 */ Run # 2356 Normal bad /* Test with LowE thr=260 */ Run # 2357 Normal bad /* Test with LowE thr=260 */ Run # 2358 Normal bad /* Test with LowE thr=260 */ Run # 2359 Normal bad /* Test with LowE thr=260 */ Run # 2360 Normal bad /* Test with LowE thr=260 */ Run # 2361 Normal bad /* Test with LowE thr=260 */ Run # 2362 Normal bad /* Test with LowE thr=260 */ Run # 2363 Nonexistent bad Run # 2364 Normal bad /* Test with LowE thr=260 */ Run # 2365 Nonexistent bad Run # 2366 Nonexistent bad Run # 2367 Normal bad /* Test with LowE thr=260 */ Run # 2368 Nonexistent bad Run # 2369 Nonexistent bad Run # 2370 Nonexistent bad Run # 2371 Normal good /* stopped because of only anti HEADER */ Run # 2372 Normal good /* memory address align on sukonh. Run summary lost in reboot */ Run # 2373 Nonexistent bad Run # 2374 Nonexistent bad Run # 2375 Nonexistent bad Run # 2376 Nonexistent bad Run # 2377 Normal bad /* test run */ Run # 2378 Nonexistent bad Run # 2379 Nonexistent bad Run # 2380 Normal bad /* Bad OD data. One ATM has no data */ Run # 2381 Nonexistent bad Run # 2382 Nonexistent bad Run # 2383 Nonexistent bad Run # 2384 Nonexistent bad Run # 2385 Nonexistent bad Run # 2386 Nonexistent bad Run # 2387 Normal bad /* test for OD board swap */ Run # 2388 Nonexistent bad Run # 2389 Normal bad /* no OD data */ Run # 2390 Nonexistent bad Run # 2391 Normal bad /* test run */ Run # 2392 Nonexistent bad Run # 2393 Normal bad /* test run */ Run # 2394 Nonexistent bad Run # 2395 Normal bad /* no data in OD Hut 2 */ Run # 2396 Nonexistent bad Run # 2397 Nonexistent bad Run # 2398 Nonexistent bad Run # 2399 Normal good /* Run summary lost in sukonh reboot */ Run # 2400 Normal good /* Normal stop for OD electronics check */ Run # 2401 Nonexistent bad Run # 2402 Nonexistent bad Run # 2403 Normal bad /* test run */ Run # 2404 Nonexistent bad Run # 2405 Normal bad /* test run */ Run # 2406 Nonexistent bad Run # 2407 Normal bad /* test run */ Run # 2408 Nonexistent bad Run # 2409 Normal bad /* test run */ Run # 2410 Nonexistent bad Run # 2411 Normal good /* Normal stop to change ATM board */ Run # 2412 Normal bad /* Continuing problems with DAQ control, slow control */ Run # 2413 Nonexistent bad Run # 2414 Nonexistent bad Run # 2415 Normal good /* Stopped because of only anti HEADER */ Run # 2416 Normal good /* Network trouble discovered at 5:30. Online network seemed to be off about 20 seconds */ Run # 2417 Normal good /* Run summary lost in sukonh reboot */ Run # 2418 Nonexistent bad Run # 2419 Nonexistent bad Run # 2420 Normal good /* Stopped because of only anti HEADER */ Run # 2421 Normal good /* Stopped because of only anti HEADER */ Run # 2422 Normal bad /* sukante collector, sukon2 sorter died */ Run # 2423 Normal good /* Stopped by sukonh reboot. Run summary lost. */ Run # 2424 Normal bad /* send_file broken pipe at 11:21 evbuild/TIMEOUT at 11:39. Run summary lost in cleanup. */ Run # 2425 Normal good /* Stopped because of no antidata. Several trips and reenables of Hut 4, ch 2.7 at 12:13 */ Run # 2426 Normal bad /* test run to investigate OD HV trips */ Run # 2427 Normal good /* sukonh reboot */ Run # 2428 Normal good /* Stopped because of only anti HEADER */ Run # 2429 Normal good /* Stopped because of only anti HEADER */ Run # 2430 Normal bad /* only anti HEADER */ Run # 2431 Normal good /* Stopped because of only anti HEADER */ Run # 2432 Normal good /* Stopped because of only anti HEADER */ Run # 2433 Normal good /* Normal stop to swipe in spare linear FIFO in Hut 2 */ Run # 2434 Normal good /* Stopped by sukonh reboot */ Run # 2435 Normal good /* Stopped because of evbuild/TIMEOUT */ Run # 2436 Normal bad /* sukonhe and sukante not working */ Run # 2437 Normal good /* stop/abort clear to do maintenance of hard disk in sukonh */ Run # 2438 Nonexistent bad Run # 2439 Normal good /* Stopped because of only anti HEADER */ Run # 2440 Normal good /* Stopped by sukonh::evbuild/TIMEOUT */ Run # 2441 Normal good /* Stopped because of only anti HEADER */ Run # 2442 Normal good /* Stopped because of only anti HEADER */ Run # 2443 Normal bad /* stopped because data did not go to kingfish */ Run # 2444 Nonexistent bad Run # 2445 Normal good /* Stopped after Kingfish hang up */ Run # 2446 Nonexistent bad Run # 2447 Normal good /* Stopped because of OD problems. Hut 4 got no hists. */ Run # 2448 Normal good Run # 2449 Normal good /* 09:35 Hut 2 ch 0.9 tripped, did not recover. 2-1-10-7 pulled during the run */ Run # 2450 Normal bad /* FIFO busy */ Run # 2451 Normal good /* Normal stop to insert LINAC beam pipe */ Run # 2452 Laser bad Run # 2453 Laser good /* Stopped because of only anti HEADER */ Run # 2454 Laser bad /* sukant collector dead */ Run # 2455 Laser bad /* sukant collector dead */ Run # 2456 Laser bad /* sukon9::collector/waitevent timeout */ Run # 2457 Nonexistent bad Run # 2458 Laser good Run # 2459 Normal good /* Stopped because of only anti HEADER */ Run # 2460 Normal good /* Stopped because of only anti HEADER */ Run # 2461 Normal good /* Normal stop to start Ni run */ Run # 2462 LINAC good /* (thr = 320) Normal stop to start LINAC run */ Run # 2463 Normal bad /* Called junk run by operators */ Run # 2464 LINAC good Run # 2465 LINAC good /* no sukant; 10 Hz */ Run # 2466 LINAC good /* During run LINAC rate raised 10.6 to 31.6 Hz */ Run # 2467 LINAC good /* with ADC data */ Run # 2468 LINAC bad /* with ADC data, only 21 events with collimator 2mm x 2mm */ Run # 2469 LINAC good /* collimator 4mm x 4mm */ Run # 2470 LINAC good /* collimator fully open */ Run # 2471 Normal good Run # 2472 Normal good /* sukon3 serial count errors started at 15:03 */ Run # 2473 Normal good /* Stopped because of only anti HEADER. At 18:03 the selector was mocified to add a new threshold channel for eliminating high energy events in Ni + Cf data taking */ Run # 2474 Nonexistent bad Run # 2475 Nonexistent bad Run # 2476 Normal good /* Normal stop for program modification */ Run # 2477 Normal good /* Normal stop to start Ni */ Run # 2478 Nonexistent bad Run # 2479 Ni bad /* z = -12 200 Hz too high for DAQ */ Run # 2480 Ni bad /* z = -12 150 Hz. Evbuild/TIMEOUT */ Run # 2481 Ni bad /* z = -12 sender error */ Run # 2482 Ni bad /* z = -12 sender error */ Run # 2483 Ni bad /* z = -12 OD HV off. Sender error */ Run # 2484 Ni bad /* z = -12 no anticounter */ Run # 2485 Ni bad /* z = -12 sukon9 not connected via ethernet */ Run # 2486 Ni bad /* z = -12 test for OD patches. Sender timeouts from all workstations. New version of OD collector did not pass tests so restored old version of 7/30 */ Run # 2487 Ni good /* z = -12 OD HV on */ Run # 2488 Ni bad /* z = -12 OD HV off */ Run # 2489 Ni good /* z = -12 Low threshold, 16 microsec window at 1 kHz */ Run # 2490 Ni good /* z = 0 normal data */ Run # 2491 Ni good /* z = 0 high PE data */ Run # 2492 Nonexistent bad Run # 2493 Ni bad /* z = 0 GONG count errors every few minutes */ Run # 2494 Ni bad /* z = 12 evbuild/TIMEOUT */ Run # 2495 Ni bad /* z = 12 cannot send data */ Run # 2496 Ni good /* z = 12 Normal stop. GONG error in 36 at 16:32 */ Run # 2497 Ni good /* z = 12 Normal stop */ Run # 2498 Ni good /* z = 12 Normal stop */ Run # 2499 Normal bad /* OD HV Hut 2-2-1 sparked */ Run # 2500 Normal bad /* only anti HEADER and 2-1-1 still sparking. 2-2-1-8 disconnected after run. */ Run # 2501 Normal bad Run # 2502 Normal good /* Stopped because of only anti HEADER */ Run # 2503 Normal good /* Stopped because of only anti HEADER */ Run # 2504 Normal bad /* collector on sukante died */ Run # 2505 Normal bad /* collector on sukante died */ Run # 2506 Normal good /* Halted by sukonh memory alignment error and reboot */ Run # 2507 Normal good /* Stopped because of FSCC/DC2 count errors in Hut 1 */ Run # 2508 Normal good /* Stopped because of no anticounter data */ Run # 2509 Normal bad /* Stopped because no data sent to Kingfish */ Run # 2510 Normal good /* Stopped to clear GPS error due to radon system being turned off */ Run # 2511 Normal good /* Stopped because sukon9e sorter dead */ Run # 2512 Normal good /* Normal stop to work on disconnected OD HV channel */ Run # 2513 Normal good /* Normal stop to work on disconnected OD HV channel */ Run # 2514 Normal good /* OD HV Hut 2 ch 1.8 and 1.9 disabled for this run. Enabled at end of run. */ Run # 2515 Normal bad /* characterized as junk by operators */ Run # 2516 Normal good /* Normal stop to perform OD software tests */ Run # 2517 Normal bad /* Test run for OD software was a failure */ Run # 2518 Normal good /* Halted by sukonh reboot */ Run # 2519 Normal good /* Stopped because of only anti HEADER */ Run # 2520 Normal bad /* sukon9 did not start */ Run # 2521 Normal good /* Stopped because of sukonh reboot */ Run # 2522 Normal good /* Normal stop at offline request */ Run # 2523 Normal bad /* sukon9 did not start */ Run # 2524 Normal bad /* sukon9 did not start */ Run # 2525 Normal bad /* collector dead on sukante, sukon1e sorter dead */ Run # 2526 Normal good /* Stopped because of no anticounter data */ Run # 2527 Normal good /* Stopped because sukant/collector dead */ Run # 2528 Normal bad /* anti LED box had veto light on */ Run # 2529 Normal bad Run # 2530 Normal good /* Stopped because of FSCC/DC2 count error in antisorter */ Run # 2531 Normal bad Run # 2532 Normal good /* Stopped because of sukonh reboot */ Run # 2533 Normal bad /* anticollector dead */ Run # 2534 Normal good /* Stopped because of sukonh evbuild/timeout */ Run # 2535 Normal good /* Normal stop at OFFLINE request */ Run # 2536 Nonexistent bad Run # 2537 Normal good /* Normal stop to request sukonh memory boards */ Run # 2538 Normal bad /* May be analyzable but has occasional 10 Hz noise because of laser tests */ Run # 2539 Normal good /* Stopped because of only anti HEADER */ Run # 2540 Nonexistent bad Run # 2541 Normal bad /* May be good but laser tests were apparently still going on according to logbook. Stopped because of OD/HV trips */ Run # 2542 Normal good /* Normal stop to change collector */ Run # 2543 Normal bad /* Normal stop to change collector */ Run # 2544 Normal bad /* May be good but laser tests were apparently still going on until 18:50. Stopped for online debug */ Run # 2545 Normal bad /* Stopped for online debug */ Run # 2546 Normal good /* Stopped for online debug */ Run # 2547 Normal good /* Normal stop for OD software tests */ Run # 2548 Normal bad /* Test run */ Run # 2549 Normal bad /* Test run */ Run # 2550 Normal good /* Stopped by sukonh reboot */ Run # 2551 Normal good /* Stopped by sukonh reboot */ Run # 2552 Normal good /* Normal stop to test stop/start sequence */ Run # 2553 Normal good /* Stopped because kingfish discovered dead at 15:50 and reboot was unsuccessful. Laser work from 14:25 to 16:05 */ Run # 2554 Normal good /* Normal stop requested by Shiozawa-san */ Run # 2555 Normal good /* Normal stop to modify software */ Run # 2556 Nonexistent bad Run # 2557 Normal good /* Normal stop to check online */ Run # 2558 Normal good /* Stopped by sukonh reboot run summary lost*/ Run # 2559 Normal good /* Normal stop for OD software tests */ Run # 2560 Normal bad /* Test run */ Run # 2561 Normal bad /* Test run */ Run # 2562 Normal bad /* Test run */ Run # 2563 Normal bad /* Test run */ Run # 2564 Normal bad /* Test run */ Run # 2565 Normal bad /* Test run */ Run # 2566 Normal bad /* Test run */ Run # 2567 Normal bad /* Test run */ Run # 2568 Normal good /* Normal stop to get SKIM back up */ Run # 2569 Normal good /* Stopped by sukonh reboot w. summary lost */ Run # 2570 Normal good Run # 2571 Normal bad /* No antidata */ Run # 2572 Normal good /* Stopped for sukonh shutdown, replacement */ Run # 2573 Normal good /* Stopped to check HV errors */ Run # 2574 Nonexistent bad /* no data, FIFO busy */ Run # 2575 Normal good /* Stopped to change bad HV board 4-7 */ Run # 2576 Nonexistent bad Run # 2577 Normal good /* Stopped because of anti header error Laser work started at 17:10 */ Run # 2578 Nonexistent bad /* no data, FIFO busy */ Run # 2579 Normal good /* Stopped because of anti header only */ Run # 2580 Normal bad Run # 2581 Nonexistent bad Run # 2582 Normal good /* Stopped because evbuild/sender(4) dead */ Run # 2583 Normal good /* Stopped because of anti header only (event # mismatch in OD)*/ Run # 2584 Normal good /* Normal stop for laser test */ Run # 2585 Normal bad /* OD did not work */ Run # 2586 Normal bad /* Laser test started 11:20. Stopped because of only anti HEADER. Judged bad because of laser. */ Run # 2587 Normal bad /* Judged bad because of laser, stopped by sukonh reboot */ Run # 2588 Normal bad /* Judged bad because of laser. Last laser run. OD HV Hut 3 ch 2.4 trip 18:54 reset 19:05 */ Run # 2589 Normal good /* Stopped to reboot kingfish. OD HV Hut 3, ch 2.4 tripped 19:34, reset 20:01, tripped 0:03 unable to reset, lowered to 1000 V 00:28 and raised to 1400 V later (correct is 1680) */ Run # 2590 Normal good /* Stopped because network connection between sukonh and sukon8 has been down. Hut 3, ch 2.4 at 1400 V until 02:35 when it was correctly raised to 1680 V */ Run # 2591 Normal good /* Stopped because sukon, sukant senders died */ Run # 2592 Normal good /* Normal stop to change sukonh boards */ Run # 2593 Normal bad /* OD DAQ tests */ Run # 2594 Normal bad /* OD DAQ tests */ Run # 2595 Normal bad /* OD DAQ tests */ Run # 2596 Normal good /* Normal stop to start Ni calibration. OD HV trips Hut 4 ch 0.8 at 20:38 and Hut 2, ch 2.11 at 21:34. Both reset at 21:40. GPS became stuck 08:35. */ Run # 2597 Ni good /* (35.3,-70.7,-1200) Bad GPS */ Run # 2598 Ni good /* (35.3,-70.7,0) Bad GPS */ Run # 2599 Ni good /* (35.3,-70.7,1200) Bad GPS */ Run # 2600 Ni good /* (35.3,-70.7,1600) */ Run # 2601 Ni good /* (35.3,-1555.4,-1200) */ Run # 2602 Ni good /* (35.3,-1555.4,0) */ Run # 2603 Ni good /* (35.3,-1555.4,1200) */ Run # 2604 Ni good /* (35.3,-1555.4,1600) */ Run # 2605 Ni good /* (35.3,-1201.9,-1200) */ Run # 2606 Ni good /* (35.3,-1201.9,0) */ Run # 2607 Ni good /* (35.3,-1201.9,1200) */ Run # 2608 Ni good /* (1520.0,-70.7,-1200) */ Run # 2609 Ni good /* (1520.0,-70.7,0) */ Run # 2610 Ni good /* (1520.0,-70.7,1200) */ Run # 2611 Ni good /* (-35.3,1554.4,-1200) */ Run # 2612 Ni good /* (-35.3,1554.4,0) */ Run # 2613 Ni bad /* (-35.3,1554.4,1200) */ Run # 2614 Ni good /* (-35.3,1554.4,1200) */ Run # 2615 Normal bad /* no antidata. collector@sukant dead */ Run # 2616 Normal bad /* no antidata. collector@sukant dead */ Run # 2617 Normal bad /* test run for OD HV */ Run # 2618 Normal good /* Stopped because OTHER - FLAG[0]. OD HV Hut 3, ch 1.1 trip at begin run. Jumper 3-1-14-7 removed 22:34. Hut 2, ch 0.7 tripped at 3:40 and turned on at 03:45 */ Run # 2619 Normal good /* Stopped to remove #10995 flasher suspect */ Run # 2620 Normal good /* Stopped because only anti HEADER */ Run # 2621 Normal bad /* Spike in trigger rate */ Run # 2622 Normal good /* but also has spikes in trigger rate at 12:40, 13:45 and at end of run */ Run # 2623 Normal good /* Stopped because of SMP memory overflow */ Run # 2624 Normal bad /* HV errors, HV rebooted */ Run # 2625 Normal good /* Normal stop requested by offline */ Run # 2626 Normal good /* Stopped to check pedestals */ Run # 2627 Normal good /* Normal stop requested by online */ Run # 2628 Normal bad /* anti-collector died */ Run # 2629 Normal good /* Normal stop to recompile OD DAQ code */ Run # 2630 Normal good /* Normal stop, replace collector software */ Run # 2631 Normal bad /* sukon 4 serial count error */ Run # 2632 Nonexistent bad Run # 2633 Normal good /* Normal stop at online request */ Run # 2634 Normal good /* Stopped by sukonh reboot */ Run # 2635 Normal bad /* collector/sorter problems */ Run # 2636 Normal bad /* netserv not running */ Run # 2637 Normal good /* Stopped after record length to replace ATM module. OD HV Hut 4, ch 0.7 and 2.3 were off for first hour of run an finally raised to correct values at 24:15. Spike in counting rate at 01:45, Aug. 30 */ Run # 2638 Normal bad Run # 2639 Normal bad /* Started without OD triggers */ Run # 2640 Normal good /* Stopped to turn off PMT #9781 as suspect flasher. Linac tests 17:00 to 19:47. Jumper 2-2-7-2 pulled around 19:45 but restored */ Run # 2641 Normal good /* Stopped because of flasher (but not removed at end of run) */ Run # 2642 Normal good /* Stopped because no OD data. HV was turned off for suspected flashers # 9825, 9781, 9839 at 12:40 */ Run # 2643 Normal good /* Stopped to turn 9825, 9781 back on */ Run # 2644 Normal bad /* Stopped because sukon1he sorter, sukante collector are dead */ Run # 2645 Normal good /* PMT 9839 off, 9825 and 9781 on. Observe flashing, which absolves 9839 */ Run # 2646 Normal good /* PMT 9839 on, 9782 off */ Run # 2647 Normal good /* PMT 9782 on, 9824 off */ Run # 2648 Normal good /* PMT 9824 on, 9869 off */ Run # 2649 Normal good /* PMT 9869 on, ID 11110 off */ Run # 2650 Normal good /* Stopped by sukonh reboot */ Run # 2651 Normal good /* Stopped by sukonh reboot */ Run # 2652 Normal bad /* collector died */ Run # 2653 Normal good /* Stopped because sukon5 sender dead. ID 11110 off and OD 21655 identified as flasher and off for run */ Run # 2654 Normal good /* Stopped by sukonh reboot */ Run # 2655 Normal good Run # 2656 Normal bad /* test with LE 296 mV */ Run # 2657 Normal bad /* test with LE 296 mV HE 30 mV */ Run # 2658 Normal bad /* test with LE 340 mV HE 28 mV */ Run # 2659 Normal bad /* test run */ Run # 2660 Normal bad /* test run */ Run # 2661 Normal bad /* test run */ Run # 2662 Normal bad /* test run */ Run # 2663 Normal bad /* test run */ Run # 2664 Normal bad /* test run */ Run # 2665 Normal bad /* test run */ Run # 2666 Normal bad /* test run */ Run # 2667 Normal bad /* test run */ Run # 2668 Normal bad /* test run */ Run # 2669 Normal bad /* test run */ Run # 2670 Normal bad /* test run */ Run # 2671 Normal bad /* test run */ Run # 2672 Normal bad /* test run */ Run # 2673 Normal bad /* anticollector dead */ Run # 2674 Normal good /* normal stop to remove od tube 20639 */ Run # 2675 Normal good /* normal stop to remove id tube 3854 and replace od tube 20639 */ Run # 2676 Normal good /* stopped by sukonh reboot */ Run # 2677 Normal good /* normal stop to do test run */ Run # 2678 Normal bad /* od hardware test run */ Run # 2679 Normal bad /* od hardware test run */ Run # 2680 Normal bad /* od hardware test run */ Run # 2681 Normal bad /* od hardware test run */ Run # 2682 Normal good /* normal stop */ Run # 2683 Normal good /* normal stop to remove hot id tubes 3490 407 4059 5256 2449 6384 10647 */ Run # 2684 Normal good /* normal stop. Some time before 03:30 Hut 4 ch 3.0 and adjacent cards were disabled for a few minutes to remove OD H 4 ch 3.0 jumper 2 */ Run # 2685 Normal bad /* sukonh::evbuild run did not start correctly */ Run # 2686 Normal good /* normal stop to temporarily remove OD suspected flashers 2-1-3-6, 1-2-11-11, 4-2-10-1, 4-1-1-7 */ Run # 2687 Normal bad Run # 2688 Normal good /* normal stop */ Run # 2689 Normal good /* normal stop to remove flasher */ Run # 2690 Normal bad /* sukante collector dead */ Run # 2691 Normal good /* normal stop to remove flasher. OD HV Hut 3 ch 0.2 (probably though log book contradicts itself) tripped at 18:43 and left at 900 V */ Run # 2692 Normal bad /* anti-trigger is not moved, data cannot be catched */ Run # 2693 Normal good /* normal stop because of 24 hour rule. OD HV Hut 3, ch 0.2 had its voltage gradually raised. Put at target value of 1770 V at 00:15 */ Run # 2694 Normal bad /* not to move anti-collector */ Run # 2695 Normal bad /* not to move anti-collector */ Run # 2696 Normal bad /* sender dead on sukon4e */ Run # 2697 Normal good /* normal stop */ Run # 2698 Normal bad /* FIFO busy */ Run # 2699 Normal good /* stopped because eventbuilder/sender dead */ Run # 2700 Normal good /* normal stop because of 24 hour rule */ Run # 2701 Normal good /* normal stop to change HV board and for sukonh maintenance */ Run # 2702 Normal good /* normal stop because of 24 hour rule */ Run # 2703 Normal bad /* Run did not start successfully */ Run # 2704 Normal good /* normal stop because spike in LOWE/HIGHE noticed at 21:00 at 60 Hz */ Run # 2705 Normal good /* normal stop for online test */ Run # 2706 Normal bad /* prescale trigger test LE = 296 mV */ Run # 2707 Normal bad /* prescale trigger test LE = 500 mV */ Run # 2708 Normal bad /* prescale trigger test LE = 500 mV */ Run # 2709 Normal bad /* prescale trigger test LE = 500 mV */ Run # 2710 Normal bad /* prescale trigger test at normal */ Run # 2711 Normal bad /* anticollector dead */ Run # 2712 Normal bad /* prescale trigger test at normal */ Run # 2713 Normal good /* sukonh other flag [0] [3] [50] */ Run # 2714 Normal good /* sukonh other flag [0] [3] [50] */ Run # 2715 Normal good /* normal stop to start Ni calibration */ Run # 2716 Ni+Cf bad /* (.35,-.707,0.0) anti on */ Run # 2717 Ni good /* (.35,-.707,0.0) anti off */ Run # 2718 Ni bad /* (.35,-.707,-12) evbuild/send[8] dead */ Run # 2719 Ni bad /* (.35,-.707,-12) sukon9 can't send data */ Run # 2720 Ni bad /* (.35,-.707,-12) */ Run # 2721 Ni bad /* (.35,-.707,-12) */ Run # 2722 Ni bad /* (.35,-.707,-12) */ Run # 2723 Ni bad /* (.35,-.707,-12) */ Run # 2724 Ni good /* (.35,-.707,-12) */ Run # 2725 Ni good /* (.35,-.707,-12) */ Run # 2726 Ni good /* (.35,-70.7,12) */ Run # 2727 Ni good /* (.35,-70.7,12) */ Run # 2728 Ni bad /* no data */ Run # 2729 Ni good /* (.35,-70.7,12) */ Run # 2730 Ni good /* (.35,-70.7,12) sender on sukon1e dead */ Run # 2731 Ni good /* (.35,-70.7,12) sender on sukon5 dead */ Run # 2732 Ni good /* (.35,-70.7,12) sender on sukon8 dead */ Run # 2733 Normal good /* evbuild/sender[7] dead */ Run # 2734 Normal good /* evbuild/sender[7] dead */ Run # 2735 Normal good /* sorter/error in Hut2-TK08 at 6:00, aborted 6:10 */ Run # 2736 Normal good /* evbuild/sender[5] dead */ Run # 2737 Normal good /* evbuild/sender[6] dead */ Run # 2738 Normal good /* evbuild/sender[4] dead */ Run # 2739 Normal good /* evbuild/sender dead */ Run # 2740 Normal bad /* timeout occured while selecting */ Run # 2741 Normal bad /* test run */ Run # 2742 Normal bad /* test run */ Run # 2743 Normal good /* Normal stop for OD test */ Run # 2744 Normal bad /* test run, ID data only */ Run # 2745 Normal good /* OD test but data good */ Run # 2746 Normal good /* evbuild/sender[0] dead */ Run # 2747 Normal good /* sukon9 sorter error */ Run # 2748 Normal bad /* sukon9 sorter error from beginning */ Run # 2749 Normal good /* evbuild/sender[4] dead */ Run # 2750 Normal bad /* collector dead on sukante */ Run # 2751 Normal good /* evbuild/sender[0] dead */ Run # 2752 Normal good /* OD HV error H4 Ch 0.1 at 15:10 */ Run # 2753 Nonexistent bad /* anticollector received signal 14 */ Run # 2754 Normal good /* sender on sukon3 died at 22:40 */ Run # 2755 Normal good /* evbuild/TIMEOUT */ Run # 2756 Normal bad /* no data in sukant */ Run # 2757 Normal bad /* no data in sukant */ Run # 2758 Normal bad /* no data in sukant */ Run # 2759 Normal good Run # 2760 Normal bad Run # 2761 Normal good /* sender [3],[4] dead */ Run # 2762 Normal bad /* sender [2], [3] dead from beginning */ Run # 2763 Normal bad Run # 2764 Normal good /* Normal stop requested by online */ Run # 2765 Normal good /* sukon1 bus error */ Run # 2766 Normal good /* Normal stop requested by online */ Run # 2767 Normal good /* sukon1 bus error */ Run # 2768 Normal good /* Normal stop requested by online */ Run # 2769 Normal good /* evbuild/sender[2] dead */ Run # 2770 Normal good /* sender on sukon3 died */ Run # 2771 Normal good /* OTHER-FLAG at 13:54 */ Run # 2772 Normal good /* antidetector dead at 20:45 */ Run # 2773 Normal good /* sender[0] dead */ Run # 2774 Normal good /* skimmer@kingfish lost data 3:30 */ Run # 2775 Normal good /* normal stop OD DAQ change */ Run # 2776 Normal bad /* OD test run */ Run # 2777 Normal bad /* OD test run */ Run # 2778 Normal bad /* OD test run */ Run # 2779 Normal bad /* OD test run */ Run # 2780 Normal bad /* OD test run */ Run # 2781 Normal bad /* OD test run */ Run # 2782 Nonexistent bad /* This run number was skipped */ Run # 2783 Nonexistent bad /* This run number was skipped */ Run # 2784 Nonexistent bad /* This run number was skipped */ Run # 2785 Nonexistent bad /* This run number was skipped */ Run # 2786 Nonexistent bad /* This run number was skipped */ Run # 2787 Nonexistent bad /* This run number was skipped */ Run # 2788 Nonexistent bad /* This run number was skipped */ Run # 2789 Nonexistent bad /* This run number was skipped */ Run # 2790 Nonexistent bad /* This run number was skipped */ Run # 2791 Nonexistent bad /* This run number was skipped */ Run # 2792 Nonexistent bad /* This run number was skipped */ Run # 2793 Nonexistent bad /* This run number was skipped */ Run # 2794 Nonexistent bad /* This run number was skipped */ Run # 2795 Nonexistent bad /* This run number was skipped */ Run # 2796 Nonexistent bad /* This run number was skipped */ Run # 2797 Nonexistent bad /* This run number was skipped */ Run # 2798 Nonexistent bad /* This run number was skipped */ Run # 2799 Nonexistent bad /* This run number was skipped */ Run # 2800 Normal bad /* anticollector died immediately */ Run # 2801 Normal bad /* anticollector died immediately */ Run # 2802 Normal good /* normal stop at online request */ Run # 2803 Normal good /* normal stop to remove OD HV #1562. Hut 1 crate 2 cards 11,12,13 turned off at 15:25. Flash event discussed in http://umdgrb.umd.edu/~goodman/trouble.jpg begins and continues long after this run */ Run # 2804 Normal bad /* sukon[14569] sender error*/ Run # 2805 Normal good /* stopped by sukonh evbuild errors */ Run # 2806 Normal bad /* multiple sukon errors from beginning */ Run # 2807 Normal good /* Normal stop requested by OD DAQ group. At 04:30 bad connections discovered and fixed on OD Hut 4, ch 2.13 & 2.14 */ Run # 2808 Normal good /* Test of DAQ debugger, but good run */ Run # 2809 Normal good /* Normal stop because of 24 hour rule */ Run # 2810 Nonexistent bad Run # 2811 Normal good /* Stopped because only anti HEADER */ Run # 2812 Normal good /* Normal stop requested by OD DAQ group */ Run # 2813 Normal bad /* OD DAQ test */ Run # 2814 Normal bad /* OD DAQ test */ Run # 2815 Normal bad /* OD DAQ test */ Run # 2816 Normal good /* Stopped because of HV errors starting at 07:26. A large section of the top of the detector became dead as HV 02 button turned red. GPS error at 06:59 fixed */ Run # 2817 Normal good /* collector died on sukant */ Run # 2818 Normal good /* stopped, senders dead. OD Hut 3 ch 1.8 tripped at 14:35 */ Run # 2819 Normal good /* OD Hut 3 ch 1.8 off until 15:00 */ Run # 2820 Normal good /* Stopped because OD Hut 3-1.8 trip 15:30 */ Run # 2821 Normal bad /* sender dead on sukante */ Run # 2822 Normal bad /* sender dead on sukante */ Run # 2823 Normal good /* Normal stop to do run tests */ Run # 2824 Normal bad /* Test run, sender not working */ Run # 2825 Normal bad /* Test run */ Run # 2826 Normal bad /* Test run */ Run # 2827 Normal good /* Stopped for OD fix */ Run # 2828 Normal bad /* OD pedestal run */ Run # 2829 Normal bad /* Test run */ Run # 2830 Normal bad /* Test run */ Run # 2831 Normal good /* Stopped by collector dead on sukante */ Run # 2832 Normal good /* Normal stop for OD test */ Run # 2833 Normal bad /* Sukante collector dead */ Run # 2834 Normal bad /* OD pedestal run */ Run # 2835 Normal bad /* FIFO busy */ Run # 2836 Normal good /* Stopped because of GONG error @sukon7 */ Run # 2837 Normal good /* Normal stop to replace ID HV board 18-5 */ Run # 2838 Normal good /* Stopped because of FIFO busy */ Run # 2839 Normal good /* Normal stop because of 24 hour rule */ Run # 2840 Normal good /* Normal stop: change test vers of SN watch*/ Run # 2841 Normal good /* Normal stop: remove ID #10455 flasher candidate */ Run # 2842 Normal good /* Normal stop. Flashing continued w/o 10455 */ Run # 2843 Normal good /* Normal stop. ID 10455 on 10409 off still flashes */ Run # 2844 Normal good /* Normal stop. ID 10455 on 10409 on 1-2-15 off does not flash. Removed jumper 1-2-15-4 */ Run # 2845 Normal bad /* FIFO busy */ Run # 2846 Normal good /* Normal stop to replace collector */ Run # 2847 Normal good /* Stopped by invalid ATM Hut 1 TK02 MA2 */ Run # 2848 Normal good /* Stopped by sender on sukon4 dead */ Run # 2849 Normal good /* Normal stop to recompile software. OD HV trip Hut 3, ch 1.8 enabled 11:15 */ Run # 2850 Normal good /* Stopped by sender on sukon3 dead */ Run # 2851 Normal bad /* collector@sukante did not start */ Run # 2852 Normal good /* Normal stop */ Run # 2853 Normal good /* Stopped because no anticounter data. OD Hut 1 ch 1.1 was off starting at 03:36:22 */ Run # 2854 Normal bad /* Test run */ Run # 2855 Normal bad /* Test run */ Run # 2856 Normal good /* Normal stop requested by OFFLINE */ Run # 2857 Normal good /* Stopped because of only anti HEADER */ Run # 2858 Normal bad /* Collector dead at sukant */ Run # 2859 Normal good /* Stopped because anticollector died */ Run # 2860 Normal bad /* Sender hang */ Run # 2861 Normal bad /* Test run */ Run # 2862 Normal good /* Normal stop for laser test */ Run # 2863 Normal bad Run # 2864 Laser bad Run # 2865 Laser bad Run # 2866 Laser bad Run # 2867 Laser good /* Filter 1350 */ Run # 2868 Laser good /* Filter 1300 */ Run # 2869 Laser good /* Filter 1250 */ Run # 2870 Laser good /* Filter 1200 */ Run # 2871 Laser good /* Filter 1150 */ Run # 2872 Laser good /* Filter 1100 */ Run # 2873 Laser good /* Filter in decrements of 50 from 1050 to 350. 2000 events @ 1050, 800 ev @ 1000 & @ 950, 600 ev at each setting from 900 to 400 and 1000 ev @ 350 */ Run # 2874 Laser good /* Filter 600 */ Run # 2875 Laser good /* Filter 450 */ Run # 2876 Laser good /* Filter 400 */ Run # 2877 Normal bad /* collector@sukon9 dead */ Run # 2878 Laser good /* Filter 350 */ Run # 2879 Normal bad /* characterized as junk by operators */ Run # 2880 Normal good /* Normal stop for offline work */ Run # 2881 Normal good /* Stopped because of only anti HEADER */ Run # 2882 Normal good /* Normal stop to exchange ATM board */ Run # 2883 Normal good /* Stopped by FSCC error. OD HV Hut 3, ch 2.11, cable 4 removed at 17:15. Had been previous trip of H3 ch 2.11 at 06:30 */ Run # 2884 Normal good /* Stopped by sukant collector dead 22:48 */ Run # 2885 Normal good /* Normal stop because network trouble */ Run # 2886 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 3 ch 1.8 tripped and enabled 6:40 and 7:50 */ Run # 2887 Normal good /* Stopped because OD HV H 4 ch 3.1 tripped, lowered to 1000 V (target 1645) */ Run # 2888 Normal good /* Stopped by FIFO busy. Hut 4 ch 3.1 @ 1100 V */ Run # 2889 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 3 ch 1.8 tripped and enabled 12:35. OD HV H4 ch 3.1 raised to 1500 at 12:24, to 1600 at 12:35 and to correct 1645 at 13:43 */ Run # 2890 Normal good /* Stopped because many extra hits in Quadrant 1 with early times */ Run # 2891 Normal good /* LINAC test started at 10:27. Operators state that extra LINAC noise is properly vetoed. ID HV errors 10/1 #10682 at 5:04, #9919 at 6:20 and #1168 at 7:30 all recovered after 10 minutes. */ Run # 2892 Normal good /* LINAC test finished at 19:57. Operators state that extra LINAC noise is properly vetoed by veto signal to TRG. Run stopped because of sukonh eventbuild TIMEOUT */ Run # 2893 Normal good /* Stopped because of evbuilder OTHERFLAG */ Run # 2894 Normal good /* Stopped because of evbuilder OTHERFLAG */ Run # 2895 Normal good /* Stopped because of invalid ATM flag */ Run # 2896 Normal good /* Normal stop to turn off ID PMT #8989 */ Run # 2897 Normal good /* Normal stop to turn off OD PMT #688 */ Run # 2898 Normal good /* Stopped because of only anti HEADER */ Run # 2899 Normal bad /* No OD data on Kingfish */ Run # 2900 Ni good /* z = -12 m. GONG count error 12:05 */ Run # 2901 Ni good /* z = 0 m. GONG count error 12:21 */ Run # 2902 Ni good /* z = 12 m. GONG count error 12:47 */ Run # 2903 Ni good /* z = 0, Kamiokande source */ Run # 2904 Cf good /* z = 0, Kamiokande source */ Run # 2905 Normal bad /* sukon4 not running */ Run # 2906 Normal bad /* no anti data on kingfish. OD HV Hut 3 ch 0.2 and Hut 4, ch 3.1 reduced to 1000 V */ Run # 2907 Normal good /* Stopped for water transparency measurement. OD HV Hut 3, ch 0.2 returned to normal voltage at 20:00 */ Run # 2908 Normal bad /* ID HV problems throughout run */ Run # 2909 Normal good /* Stopped because of OTHERFLAG and serial count error. At 2:00 Hut 4 ch 2.10 set to 1000 V after trip. */ Run # 2910 Normal good /* Stopped, water transparency measurement. */ Run # 2911 Normal good /* Stopped because of sukon 7 serial count error. OD HV Hut 4, ch 0.4 tripped, turn on seemed to cause 1/8 of wall to light up */ Run # 2912 Normal good /* Stopped, sukon7 serial count error */ Run # 2913 Normal good /* Stopped because of OD HV Hut 4 ch 0.8 problems. Tripped 11:36, restored 11:47. Tripped again at unspecified times, voltage lowered to 1000 V at 14:58. Jumper #8 in Hut 4, ch 0.8 removed at end of run */ Run # 2914 Normal good /* Stopped because of only anti HEADER */ Run # 2915 Normal good /* Stopped because anti collector dead */ Run # 2916 Normal good /* Stopped because of strange numbers in pmonitor display */ Run # 2917 Normal good /* Normal stop to fix OD PMT */ Run # 2918 Normal bad /* sukante collector did not run */ Run # 2919 Normal good /* Special run to test OD HV 2-1-12. Jumper 2-1-12-3 removed at end of run */ Run # 2920 Normal good /* Stopped because of FIFO busy */ Run # 2921 Normal good /* Stopped because OD HV Hut 4, ch 0.4 gave no data, had been turned down to 1000 V. No logbook comment on this channel since Run 2911 */ Run # 2922 Normal good /* Stopped because of only ant HEADER */ Run # 2923 Normal bad /* anticollector did not start */ Run # 2924 Normal good /* Stopped because of only ant HEADER. LINAC tests started at 10:00. FSCC rebooted at 10:36 */ Run # 2925 Normal bad /* anticollector did not start */ Run # 2926 Normal good /* Stopped because pmonitor CPU time bad */ Run # 2927 Normal bad /* FIFO busy */ Run # 2928 Normal bad /* Hut 2 TDC busy */ Run # 2929 Normal good /* Stopped because of evbuild OTHERFLAG */ Run # 2930 Normal good /* Stopped because of only anti HEADER. LINAC tests started at 09:01. OD HV Hut 1, ch 1.1 off 02:35 to 03:35 */ Run # 2931 Normal bad /* sukante collector stopped */ Run # 2932 Normal good /* Normal stop because of 24 hour rule. LINAC test finished 20:00 then started 09:10 */ Run # 2933 Normal good /* Normal stop to remove OD tube #20895 */ Run # 2934 Normal bad /* test run */ Run # 2935 Normal bad /* test run */ Run # 2936 Normal bad /* OD busy */ Run # 2937 Normal bad /* OD busy */ Run # 2938 Normal good /* Stopped because pmonitor died */ Run # 2939 Normal good /* Stopped because only anti HEADER */ Run # 2940 Normal bad /* FIFO busy */ Run # 2941 Normal bad /* OD collector died */ Run # 2942 Normal good /* Stopped because OTHERFLAG detected */ Run # 2943 Normal bad /* FIFO busy */ Run # 2944 Normal good /* Stopped because of 24 hour rule */ Run # 2945 Normal good /* Stopped because of 24 hour rule */ Run # 2946 Normal good /* Stopped to replace high voltage cards. At 06:30 10/13 major ID HV error Hut 2, ATM10 slots 7 and 8 */ Run # 2947 Normal bad /* test, sukante collector died */ Run # 2948 Normal bad /* test, sukante collector died */ Run # 2949 Normal bad /* test of board change but may be good */ Run # 2950 Normal bad /* stopped because anticollector dead */ Run # 2951 Normal good /* Stopped because of evbuild/TIMEOUT. Prob- lems begin with Flasher#59. See runs 2998 and 2999 for explanation */ Run # 2952 Normal good /* Stopped because of OTHERFLAG. YAG laser started 10:45. Skim, skimmer, getreal died, restarted 12:00 */ Run # 2953 Normal bad /* sukante collector dead, FIFO VME busy */ Run # 2954 Normal good /* Normal stop requested by Laser group */ Run # 2955 Normal good /* Normal stop requested by offline. Laser testing was done */ Run # 2956 Normal bad /* FIFO busy */ Run # 2957 Normal bad /* OD collector dead */ Run # 2958 Normal bad /* OD collector dead Hut 2 FCC */ Run # 2959 Normal good /* Normal stop to remove flashers OD 4-1-5-12 and to drop HV of ID 5702 -900 V */ Run # 2960 Normal bad /* Test run */ Run # 2961 Normal bad /* OD collector dead */ Run # 2962 Normal good /* Normal stop to test low energy trigger */ Run # 2963 Normal bad /* OD collector dead */ Run # 2964 Normal bad /* OD collector dead */ Run # 2965 Normal good /* Stopped, frequent anti HEADER only */ Run # 2966 Normal good /* Stopped, frequent anti HEADER only */ Run # 2967 Normal bad /* OD collector dead */ Run # 2968 Cf good Run # 2969 Cf bad /* no anticollector */ Run # 2970 Normal good /* Stopped by ATM error Hut 3 TK03 */ Run # 2971 Normal good Run # 2972 Normal good /* superlowE trigger on by mistake, turned off at end of run */ Run # 2973 Normal good /* Stopped by FSCC busy. Laser test starting 10/15, 15:13. OD HV trip Hut 3, ch 1.8 reset at 0:45 and 01:15, same trip at 12:23 reset 12:29 */ Run # 2974 Normal good /* Stopped because NOVA broken. OD HV trip Hut 3, ch 1.8 reset 19:50. Tripped again at 20:00, cooked at 500 V, restored 20:30, tripped 21:55, arcing noticed and board left unplugged. */ Run # 2975 Normal good /* Normal stop requested by on-line */ Run # 2976 Normal good /* Stopped to turn off OD HV channel */ Run # 2977 Normal bad /* sukant collector did not run */ Run # 2978 Normal good /* Normal stop to start Ni calibration. OD HV Hut 3 ch 1.8 started at 1800 V slowly increased, at 1945 at 01:40 */ Run # 2979 Cf bad /* Stopped because only anti HEADER. ID HV 3,8,12,21,22,28,31, off */ Run # 2980 Cf good Run # 2981 Ni bad /* z = -12 stopped because ID HV board crate #12 broken, fixed for next run */ Run # 2982 Ni good /* z = -12 */ Run # 2983 Ni good /* z = 0 */ Run # 2984 Ni good /* z = 12 */ Run # 2985 Normal good /* Stopped because only anti HEADER */ Run # 2986 Normal bad /* Hut 2 TDC busy, sukant collector dead */ Run # 2987 Normal good /* Stop requested by Laser group */ Run # 2988 Normal good /* Stop requested by Laser group. Laser work was done throughout this run. */ Run # 2989 Normal good /* Stopped because only anti HEADER */ Run # 2990 Normal good /* Stopped because invalid ATM Hut 3 TK07 */ Run # 2991 Normal bad /* FIFO busy */ Run # 2992 Normal good /* Normal stop. LINAC beam test started 11:00. Laser work started 14:42. Hut 2, ch 2.5 tripped 14:50 set at 1000 V */ Run # 2993 Normal bad /* Collector dead on sukante */ Run # 2994 Normal bad /* Test run, ID PMT 6086 reduced -840 V. OD HV jumper 2-2-10-10 removed */ Run # 2995 Normal bad /* FIFO busy */ Run # 2996 Normal good /* Stopped because beep from only anti HEADER would not go away. Messages started 60 minutes into 75 minute run */ Run # 2997 Normal good /* Stopped because Hut 2 FSCC TDC busy */ Run # 2998 Normal good /* Stopped to remove possible flasher-21009. Identified as flasher #59 in high energy analysis. Flasher #59 gone after this run. LINAC test finished 20:50 (nine minutes into 19.5 hour run) */ Run # 2999 Normal bad /* Test run to remove OD flasher candidate 21009 and replace 21026. ID Pmt 6086 revived */ Run # 3000 Normal good /* Stopped because message control program is dead */ Run # 3001 Normal bad /* Hut 2 busy */ Run # 3002 Normal good /* Normal stop requested by offline */ Run # 3003 Normal good /* Normal stop due to 24 hour rule */ Run # 3004 Normal good /* Normal stop to disable noisy PMT 10580 */ Run # 3005 Normal bad /* No antidata */ Run # 3006 Normal good /* Normal stop due to 24 hour rule */ Run # 3007 Normal bad /* Stopped because FIFO busy */ Run # 3008 Normal bad Run # 3009 Normal good /* Normal stop to turn off flasher OD Hut 1-2-15-12, #21790 */ Run # 3010 Normal bad Run # 3011 Normal good /* Normal stop to check for flasher. At 03:30 OD HV Hut 4 ch 0.3, 0.4, 0.5 enabled */ Run # 3012 Normal bad /* FIFO busy */ Run # 3013 Normal good /* Stopped because collector dead on sukon5 */ Run # 3014 Normal good /* Stopped because of HV trips. Laser work started 2 hours into run and lasted 2 hours (15:00 to 17:00). Hut 3 Ch 2.6 tripped 22:59 and was enabled, and again at 23:46, 05:40, 05:44, 05:47. OD Hut 3 ch 2.6 lowered to 1570 V at 05:47 trip, to 1550 V at 05:59 trip, to 1500 V at 06:05 trip */ Run # 3015 Normal bad /* no data */ Run # 3016 Normal good /* Stopped because evbuilder/TIMEOUT */ Run # 3017 Normal good /* Stopped to reboot Kingfish for new software */ Run # 3018 Normal good /* Normal stop because of 24 hour rule. OD cable installation error discovered 00:20. */ Run # 3019 Normal good /* Normal stop because of 24 hour rule. Between 00:30 and 01:30 OD HV was turned off and on for Hut 4, ch 0.7. Jumpers 2, 3, AND 5 were all removed from that card. */ Run # 3020 Normal bad /* no data (FIFO busy) */ Run # 3021 Normal good /* Normal stop because of 24 hour rule. Laser job 10/29 at 11:01 */ Run # 3022 Normal good /* Stopped because sukon9e collector died */ Run # 3023 Normal good /* Stopped because sukon09 collector died */ Run # 3024 Normal good /* Normal stop because of 24 hour rule. Laser job 10/31 at 11:52 */ Run # 3025 Normal good /* Stopped because of OD HV problems in Hut 4. Power supply in error state and unreachable starting at 08:20 on 11/1 . Last dozen plus subruns probably bad */ Run # 3026 Normal bad /* Collector on sukante dead throughout run */ Run # 3027 Normal bad /* Stopped by FIFO VME busy. */ Run # 3028 Normal good /* Stopped because sukon09 collector died. Hut 4 HV supply replaced for this run */ Run # 3029 Normal good /* Normal stop for OD PMT testing */ Run # 3030 Normal bad /* OD PMT test run */ Run # 3031 Normal bad /* OD PMT test run */ Run # 3032 Normal bad /* OD PMT test run. Returned OD PMTs 3-1-2-8, 3-2-2-1, 4-1-8-5, 4-1-8-2 and 4-2-13-6 to service */ Run # 3033 Normal good /* Normal stop because of 24 hour rule */ Run # 3034 Normal bad /* FIFO busy */ Run # 3035 Normal good /* Normal stop because of 24 hour rule */ Run # 3036 Normal bad /* FIFO busy */ Run # 3037 Normal good /* Normal stop because of 24 hour rule */ Run # 3038 Normal good /* Stopped by evbuild error */ Run # 3039 Normal bad /* Hut 3 TDC busy */ Run # 3040 Normal good /* Stopped because sukon9 collector dead */ Run # 3041 Normal good /* Stopped because sukon9 collector dead */ Run # 3042 Normal good /* Normal stop to turn off flasher, cable #8815 */ Run # 3043 Normal good /* Stopped by evbuild/TIMEOUT */ Run # 3044 Normal good /* Normal stop because of 24 hour rule */ Run # 3045 Normal bad /* FIFO VME busy */ Run # 3046 Normal bad /* Hut 2 busy */ Run # 3047 Normal bad /* Stopped by evbuild/TIMEOUT. ATM errors make run bad for analysis */ Run # 3048 Normal bad /* collector dead on sukante */ Run # 3049 Normal bad /* Stopped by Badsel error. ATM errors make run bad for analysis */ Run # 3050 Normal bad /* VME busy */ Run # 3051 Normal bad /* ATM data are strange */ Run # 3052 Normal bad /* ID HV 22-3 not on */ Run # 3053 Normal bad /* Hut 4 busy */ Run # 3054 Normal bad /* Hut 2 busy */ Run # 3055 Normal good /* Stopped because OD Hut 3, ch 1.7 tripped ten minutes before end of run */ Run # 3056 Normal good /* Stopped because of multiple online errors. Spike in antitrigger rate at 17:18 */ Run # 3057 Normal bad /* Stopped because of multiple online errors. Spike in antitrigger rate at 17:30 */ Run # 3058 Normal good /* Stopped because of GONG count error, Hut 1 TK07 and Hut 1 TK08 */ Run # 3059 Normal good /* Stopped because of sukon6 insufficient event buffer */ Run # 3060 Normal good /* Stopped because of spike in antitrigger */ Run # 3061 Normal bad /* Hut 2 trigger output empty, caused anti trigger to disappear */ Run # 3062 Normal good /* Normal stop due to 24 hour rule */ Run # 3063 Normal good /* Normal stop due to 24 hour rule */ Run # 3064 Normal bad /* Collector on sukante dead */ Run # 3065 Normal bad /* anticollector dead */ Run # 3066 Normal good /* Normal stop due to 24 hour rule */ Run # 3067 Normal good /* Normal stop for online software */ Run # 3068 Normal bad /* OD DAQ dead */ Run # 3069 Normal bad /* OD DAQ dead */ Run # 3070 Normal good /* Normal stop due to 24 hour rule */ Run # 3071 Normal good /* Stopped because sorter in sukant dead */ Run # 3072 Normal good /* Stopped to remove flasher OD 4-2-9-1 #21371 */ Run # 3073 Normal bad /* VME FIFO busy on OD */ Run # 3074 Normal bad /* FIFO busy */ Run # 3075 Normal bad /* Test run for HV maintenance, Hut 4. Sukon 7,8 off */ Run # 3076 Normal bad /* Test run for HV maintenance. Sukon 5,6,7,8 off. Sukant did not start */ Run # 3077 Normal bad /* Test run. Hut 3,4 off */ Run # 3078 Normal bad /* Test run. Sukon 1,2,5,6: Hut 1,3 off */ Run # 3079 Normal bad /* Test run. Sukon 1,2,5,6: Hut 1,3 off. Hut 2 crate 13,14,15,16,17 HV off */ Run # 3080 Normal bad /* Test run. Sukon 1,2: Hut 1 off. Hut 2 crate 13,14,15,16,17 HV off */ Run # 3081 Normal bad /* sukant collector did not work */ Run # 3082 Normal bad /* Test run */ Run # 3083 Normal bad Run # 3084 Normal good /* Normal stop to measure water transparency. ID PMT #3979 reduced -600 V at 18:29 */ Run # 3085 Normal good /* Normal stop to turn on Hut 3,4 lights. Hut 3 ch 1.7 tripped, enabled 23:50 */ Run # 3086 Normal bad /* sukan9 collector dead */ Run # 3087 Normal bad /* sukant collector did not work */ Run # 3088 Normal good /* Normal stop to replace sukop memory board. QTC cable discovered disconnected at 03:30 for Hut 4-2-10-(6 to 12) and restored */ Run # 3089 Normal bad Run # 3090 Normal good /* OD #20216 1-1-19-11 removed as flasher, #21371 returned */ Run # 3091 Normal good /* Normal stop to start test run */ Run # 3092 Normal bad /* Test run for tube repare */ Run # 3093 Normal bad /* Test run for tube repare. ID Hut 4 board 8 ch 18 disconnected after run */ Run # 3094 Normal bad /* HV of crate 43 not turned on */ Run # 3095 Normal bad /* FIFO VME busy */ Run # 3096 Normal good /* Stopped because sukon senders died. OD PMT #21307 4-2-13-6 disconnected as flasher */ Run # 3097 Ni good /* z = -12 m */ Run # 3098 Ni good /* z = 0 m */ Run # 3099 Ni good /* z = 12 m */ Run # 3100 Normal bad /* The first 20 minutes (two subruns) of this run are salvageable, but at 21:30 HV crate 2 was turned off to fix a bad board. The run was eventually stopped due to ID HV crate 2 being broken */ Run # 3101 Normal bad /* OD HV Hut 3 tripped */ Run # 3102 Normal good /* Stopped because invalid NOVA, sorters dead */ Run # 3103 Normal good /* Normal stop to replace ID HV card crate 2 board 0 */ Run # 3104 Normal bad /* evbuilder did not send data */ Run # 3105 Normal bad /* FSCC Hut 2 busy */ Run # 3106 Normal good /* Stopped because pmonitor/sukon9e not connected via ethernet */ Run # 3107 Normal bad /* sukant collector is dead */ Run # 3108 Normal bad /* sukant collector is dead */ Run # 3109 Normal bad /* sukant collector is dead */ Run # 3110 Normal bad /* FSCC Hut 2 busy */ Run # 3111 Normal good /* Stopped by FSCC Hut 1 word count error */ Run # 3112 Normal bad /* FSCC Hut 2 busy */ Run # 3113 Normal good Run # 3114 Normal bad /* Called junk by operators */ Run # 3115 Normal good /* Stopped because of FIFO busy */ Run # 3116 Normal bad /* Called junk by operators. Trigger rate high then low after OD PMT #21243 4-2-5-1 disconnected */ Run # 3117 Normal good /* Normal stop due to 24 hour rule */ Run # 3118 Normal bad /* sukon9 sender not runing from start */ Run # 3119 Normal good /* Normal stop due to ID HV trip Hut 3 crate 11 ATM 3-11-8,3-11-7 */ Run # 3120 Normal good /* HV 35 board #3 fixed during run */ Run # 3121 Nonexistent bad Run # 3122 Normal bad /* no antidata, antisender waits on evbuild */ Run # 3123 Normal bad /* no antidata after about 100 events */ Run # 3124 Normal bad /* no antidata */ Run # 3125 Normal bad Run # 3126 Normal good /* Stopped for OD HV trip Hut 1-3-1 01:00 */ Run # 3127 Normal bad /* VME FIFO busy */ Run # 3128 Normal bad /* OD HV Hut 1 off to search for bad tube */ Run # 3129 Normal bad /* OD collector dead/Hut 2 error */ Run # 3130 Normal good /* Normal stop requested by offline */ Run # 3131 Normal good /* Normal stop because of 24 hour rule */ Run # 3132 Normal bad /* FIFO busy */ Run # 3133 Normal good /* OD HV cables 16,17, Hut 1 cr 2 fell out at 12:00 */ Run # 3134 Normal good /* Normal stop for UPS change */ Run # 3135 Normal bad /* Test run with no data */ Run # 3136 Normal bad /* Antisorter has split trigger cap */ Run # 3137 Normal good /* Normal stop because of 24 hour rule. LINAC test 11:00 to 20:30 */ Run # 3138 Normal good /* Normal stop because of 24 hour rule */ Run # 3139 Normal bad /* FIFO busy */ Run # 3140 Normal good /* Stopped to remove OD PMT 4-1-3-11 */ Run # 3141 Normal bad /* FIFO busy */ Run # 3142 Normal good /* Normal stop because of 24 hour rule */ Run # 3143 Normal good /* Normal stop because of 24 hour rule */ Run # 3144 Normal bad /* OD FIFO busy */ Run # 3145 Normal bad /* OD Hut 2 TDC busy */ Run # 3146 Normal good /* Stopped to turn flasher ID cable #10079 HV off. LINAC testing 10:00 to 16:50 */ Run # 3147 Normal bad /* Anticollector frozen after reading DPMs */ Run # 3148 Normal good /* Normal stop because of 24 hour rule. LINAC test 09:40 to 19:00 */ Run # 3149 Normal good /* Normal stop because of 24 hour rule */ Run # 3150 Normal bad /* anticollector dead */ Run # 3151 Normal good /* Normal stop because of 24 hour rule */ Run # 3152 Normal good /* Normal stop to set up p-decay hardware simulation system */ Run # 3153 Xe bad /* p nuK muon+gamma test PIN photodiode trigger */ Run # 3154 Xe good /* p nuK muon+gamma test PIN photodiode trigger */ Run # 3155 Xe good /* p nuK muon+gamma test PIN photodiode trigger */ Run # 3156 Xe good /* p nuK muon only filter=1350 */ Run # 3157 Xe good /* p nuK muon only filter=1150 */ Run # 3158 Xe good /* p nuK muon only filter=1050 */ Run # 3159 Xe good /* p nuK muon only filter=1000 */ Run # 3160 Xe good /* p nuK muon only filter=950 */ Run # 3161 Xe good /* p nuK muon only filter=800 */ Run # 3162 Xe good /* p nuK muon only filter=800-2 */ Run # 3163 Xe good /* p nuK muon only filter=950-2 */ Run # 3164 Xe good /* p nuK muon only filter=1000-2 */ Run # 3165 Xe good /* p nuK muon only filter=1050-2 */ Run # 3166 Xe bad /* p nuK muon only filter=1150-2 */ Run # 3167 Xe good /* p nuK muon only filter=1150-2 */ Run # 3168 Xe good /* p nuK muon only filter=1350-2 */ Run # 3169 Xe good /* p nuK gamma only filter=1300 */ Run # 3170 Xe good /* p nuK gamma only filter=1150 */ Run # 3171 Xe good /* p nuK gamma only filter=900 */ Run # 3172 Xe good /* p nuK gamma only filter=850 */ Run # 3173 Xe good /* p nuK BG run (laser on) */ Run # 3174 Xe good /* p nuK gamma only filter=1000 */ Run # 3175 Xe bad /* p nuK gamma only filter=1100, wrong filter set */ Run # 3176 Xe good /* p nuK gamma only filter=1100 */ Run # 3177 Xe good /* p nuK gamma only filter=850 */ Run # 3178 Xe good /* p nuK gamma only filter=900 */ Run # 3179 Xe good /* p nuK gamma only filter=1000, no data */ Run # 3180 Xe good /* p nuK gamma only filter=1000 */ Run # 3181 Xe good /* p nuK gamma only filter=1100 */ Run # 3182 Xe good /* p nuK gamma only filter=1150 */ Run # 3183 Xe good /* p nuK gamma only filter=1300 */ Run # 3184 Xe good /* p nuK gamma only filter=970,1100 */ Run # 3185 Xe good /* p nuK gamma only f=990,1100 d=10ns */ Run # 3186 Xe good /* p nuK gamma only f=990,1100 d=15ns */ Run # 3187 Xe good /* p nuK gamma only f=1000,1100 d=20ns */ Run # 3188 Xe good /* p nuK gamma only f=1010,1100 d=20ns */ Run # 3189 Normal good /* Stopped because Kenkyuto power failure */ Run # 3190 Normal bad /* Sukant collector did not start */ Run # 3191 Normal bad /* Hut 2 TDC busy */ Run # 3192 Normal good /* Stopped because VME busy */ Run # 3193 Normal good /* Stopped to kill flasher cable 5878. Event rate a factor of two high */ Run # 3194 Normal bad /* OD FIFO busy */ Run # 3195 Normal good /* Normal stop because of 24 hour rule */ Run # 3196 Normal good /* Stopped for transparency measurement. At 10:30 to 10:45 OD HV lowered for Hut 3 ch 1.8 because of trip */ Run # 3197 Normal good /* Stopped because FIFO busy. ID HV 32-6 off during run */ Run # 3198 Normal bad /* Test run to fix ID, OD HV problems (ID Crate 32 off, OD Hut 3 problems) */ Run # 3199 Normal bad /* anticollector dead */ Run # 3200 Normal bad /* anticollector dead */ Run # 3201 Normal bad /* Test run to fix OD Hut 3 problems */ Run # 3202 Normal bad /* Test run to fix OD Hut 3 problems */ Run # 3203 Normal bad /* Test run */ Run # 3204 Normal good /* Stopped for water transparency test */ Run # 3205 Normal good /* Stopped because no antidata */ Run # 3206 Normal good /* Stopped because of 24 hour rule */ Run # 3207 Normal good /* Normal stop for Xe data taking */ Run # 3208 Xe bad /* Characterized as junk by operators */ Run # 3209 Xe good /* LED */ Run # 3210 Xe good Run # 3211 Xe good Run # 3212 Xe bad /* Characterized as junk by operators */ Run # 3213 Xe good Run # 3214 Xe good Run # 3215 Xe bad /* LED, characterized as junk by operators */ Run # 3216 Xe good /* LED */ Run # 3217 Xe bad /* Sukante collector dead */ Run # 3218 Xe good /* LED */ Run # 3219 Xe good Run # 3220 Xe bad /* Sukante collector dead */ Run # 3221 Xe good /* LED */ Run # 3222 Xe good Run # 3223 Xe good /* LED */ Run # 3224 Xe bad /* Sukante collector dead */ Run # 3225 Xe good Run # 3226 Xe good /* LED */ Run # 3227 Xe good Run # 3228 Xe good /* LED */ Run # 3229 Xe good Run # 3230 Xe good /* LED */ Run # 3231 Xe good Run # 3232 Xe good /* LED */ Run # 3233 Xe good Run # 3234 Xe good /* LED */ Run # 3235 Xe good Run # 3236 Xe good /* LED */ Run # 3237 Xe bad /* Sukante collector dead */ Run # 3238 Xe good Run # 3239 Xe good /* LED */ Run # 3240 Xe good Run # 3241 Normal good /* Normal stop due to 24 hour rule */ Run # 3242 Normal good /* Stopped because data flow processes stopped -- disk full. OD HV Hut 4 ch 0.4 trip, reset 19:45 */ Run # 3243 Normal good /* Stopped because sender at sukon9 died */ Run # 3244 Normal good /* Stopped because ID data from half of Hut 1 seemed bad (bad T and Q data at 06:57) */ Run # 3245 Normal good /* Stopped because power going down at Kenkyuto */ Run # 3246 Normal good /* Stopped because FIFO busy */ Run # 3247 Normal good /* Normal stop to start Ni data */ Run # 3248 Ni good /* z = -12 m */ Run # 3249 Ni good /* z = 0 m */ Run # 3250 Ni good /* z = 12 m */ Run # 3251 Normal good /* Stopped because of only anti HEADER. LINAC testing until 22:30. OD HV Hut 1 ch 2.10 trip reset 08:15 */ Run # 3252 Normal good /* Normal stop requested by offline */ Run # 3253 Normal bad /* pmonitor collector dead on sukante */ Run # 3254 Normal bad /* pmonitor collector dead on sukante */ Run # 3255 Nonexistent bad Run # 3256 Normal good /* Normal stop to insert beam pipe for LINAC */ Run # 3257 Random bad /* Random trigger with few events */ Run # 3258 Normal bad /* Test run with split trigger (OD DAQ triggered only on HE events) */ Run # 3259 Normal bad /* Test run with split trigger (OD DAQ triggered only on HE events, LE threshold=280 mV) */ Run # 3260 Normal good /* Stopped because ID Hut 1 crate 8 died at 18:17. Last three subruns bad. */ Run # 3261 Normal bad /* Junk run to fix ID */ Run # 3262 Normal bad /* OD Hut 4 busy */ Run # 3263 Normal bad /* Test run for HV repair */ Run # 3264 Normal good /* Stopped to check high current tube. OD Hut 1 ch 2.10 tripped and recovered repeatedly starting 22:56 */ Run # 3265 Normal bad /* Junk run to check high current tube. OD PMT 1-2-15-10 disconnected */ Run # 3266 Normal good /* Normal stop requested by LINAC to adjust trigger. Some LINAC work during run increases LE trigger */ Run # 3267 LINAC good Run # 3268 LINAC bad /* With ADC, no events */ Run # 3269 LINAC good Run # 3270 LINAC bad /* With ADC, no events -- FIFO busy */ Run # 3271 LINAC good /* With ADC, high and low energy triggers also listed. 15 MeV/c */ Run # 3272 Normal good /* With ADC, high trigger rate */ Run # 3273 LINAC good /* With ADC, 8 MeV/c */ Run # 3274 LINAC good /* With highe and lowe triggers. 8 MeV/c */ Run # 3275 Normal bad /* LINAC tuning, no events */ Run # 3276 LINAC good /* With highe and lowe triggers */ Run # 3277 LINAC good /* With ADC, 6 Mev/c */ Run # 3278 LINAC good /* With highe and lowe triggers, 6 MeV/c */ Run # 3279 LINAC good /* With highe and lowe triggers. 6 MeV/c */ Run # 3280 Normal good /* Normal stop requested by LINAC */ Run # 3281 Normal good /* LINAC work during run */ Run # 3282 LINAC good /* Also lowe and highe and null trigger */ Run # 3283 LINAC good /* With highe and lowe triggers */ Run # 3284 Normal good Run # 3285 LINAC good /* 7 MeV/c */ ARun # 3286 LINAC good /* With highe and lowe and null triggers. OD suspected flasher hut 2-2-17-7 removed at end of run */ Run # 3287 Normal good /* Stopped because sukant collector dead */ Run # 3288 Normal good /* Normal stop requested by LINAC */ Run # 3289 Normal bad /* FIFO busy */ Run # 3290 Normal good /* Stopped because OD FIFO busy */ Run # 3291 Normal bad /* Test run with sukon7 off to fix FDDI. HV cable# 1502 lowered at 19:50 */ Run # 3292 Normal bad /* Test run with sukon7 off to fix FDDI */ Run # 3293 Normal good /* Normal stop for water transparency measurement */ Run # 3294 Normal bad /* ID Hut 3 Crate 11 did not come on */ Run # 3295 Normal good /* Normal stop due to 24 hour rule */ Run # 3296 Normal good /* Stopped due to OD HV problem Hut 1-1-15 but problem went away (high current) */ Run # 3297 Normal bad /* Test run, anticollector dead no data */ Run # 3298 Normal bad /* Test run, anticollector dead no data */ Run # 3299 Normal good /* Stopped because of OD Hut 1-1-15 died. Reset. */ Run # 3300 Normal good /* Stopped because no anticounter data */ Run # 3301 Normal good /* Normal stop requested by online group. High rate of ID #5879 blamed on suspected OD flasher 4-1-2-11. OD flasher turned off at end of run */ Run # 3302 Normal bad /* An ID HV crate was down */ Run # 3303 Normal good /* Normal stop due to 24 hour rule */ Run # 3304 Normal good /* Normal stop to change ATM board 4-2-3 */ Run # 3305 Normal good /* Normal stop to change ATM board again */ Run # 3306 Normal bad /* OD collector dead */ Run # 3307 Normal good /* Normal stop to turn on superlowe trigger */ Run # 3308 Normal bad /* collector on sukant dead */ Run # 3309 Normal bad /* Superlowe trigger. Normal stop */ Run # 3310 Normal bad /* Superlowe trigger, stopped because of only anti HEADER */ Run # 3311 Normal bad /* Superlowe trigger, stopped by OD down */ Run # 3312 Normal bad /* Superlowe trigger, stopped by OD down */ Run # 3313 Normal good /* Normal stop due to 24 hour rule. LINAC test 15:20 to 15:50 */ Run # 3314 Normal good /* Normal stop to prepare Ni calibration. LINAC test 23:00 to 03:20 */ Run # 3315 Normal bad /* no OD */ Run # 3316 Normal bad /* sukon9 file system full */ Run # 3317 Normal bad /* lowe trigger not on */ Run # 3318 Normal good /* Normal stop due to 24 hour rule */ Run # 3319 Normal good /* Normal stop due to 24 hour rule */ Run # 3320 Normal good /* Normal stop due to 24 hour rule */ Run # 3321 Normal good /* Stopped because antisorter count error */ Run # 3322 Normal good /* Normal stop to recover Kingfish */ Run # 3323 Normal good /* Stopped because of only anti HEADER */ Run # 3324 Normal good /* Normal stop due to 24 hour rule. OD HV trip reset 22:55 Hut 1 ch 3.2 */ Run # 3325 Normal good /* Normal stop to test online system */ Run # 3326 Normal bad /* Superlowe 250 mV. OD Hut 1-2-19-6 (#21870) jumper removed (bad tube) */ Run # 3327 Normal bad /* Superlowe 245 mV */ Run # 3328 Normal bad /* Superlowe 245 mV */ Run # 3329 Normal bad /* Superlowe 245 mV */ Run # 3330 Normal bad /* Superlowe 245 mV */ Run # 3331 Normal bad /* Superlowe 245 mV */ Run # 3332 Normal bad /* Superlowe 245 mV. Change readout timing 64 to 99 */ Run # 3333 Normal bad /* Superlowe without ACK */ Run # 3334 Normal bad /* Superlowe 240 mV */ Run # 3335 Normal bad /* Superlowe 244 mV */ Run # 3336 Normal bad /* No antidata */ Run # 3337 Normal bad /* No antidata */ Run # 3338 Normal bad /* No antidata */ Run # 3339 Normal good /* Normal stop for water transparency test */ Run # 3340 Ni bad /* Stopped because of online problem */ Run # 3341 Ni bad Run # 3342 Ni good /* z = 0 */ Run # 3343 Normal bad /* BIP and GLB Flag on */ Run # 3344 Normal bad Run # 3345 Normal bad /* BIP and GLB */ Run # 3346 Normal bad /* BIP and GLB */ Run # 3347 Normal bad Run # 3348 Normal bad /* BIP and GLB */ Run # 3349 Normal good /* Normal stop due to 24 hour rule */ Run # 3350 Normal bad /* Characterized as junk by operators */ Run # 3351 Normal good /* Stopped for ID HV #10436 (11-0-9) off */ Run # 3352 Normal good /* Normal stop due to 24 hour rule */ Run # 3353 Normal good /* Stopped for OD HV error H3 ch 0.4 */ Run # 3354 Normal good /* Stopped to remove noisy OD 1-1-19-10 */ Run # 3355 Normal bad /* FIFO busy */ Run # 3356 Normal good /* Normal stop due to 24 hour rule. VME board of Hut 2 reset at 13:00 */ Run # 3357 Normal good /* Normal stop due to 24 hour rule */ Run # 3358 Normal good /* Stopped by pmonitor/sukon1e connection error */ Run # 3359 Normal bad /* LED red on, characterized as junk */ Run # 3360 Normal good /* Normal stop due to 24 hour rule */ Run # 3361 Normal good /* Normal stop due to 24 hour rule */ Run # 3362 Normal good /* Stopped due to only anti HEADER */ Run # 3363 Normal good /* Stopped due to power failure */ Run # 3364 Normal bad /* anticollector dead */ Run # 3365 Normal good /* Normal stop due to 24 hour rule */ Run # 3366 Normal good /* Stopped due to evbuild/OTHER_FLAG */ Run # 3367 Normal good /* Normal stop due to 24 hour rule */ Run # 3368 Normal good /* Stopped due to evbuild/server error */ Run # 3369 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 2 ch 3.0 tripped, reset 18:40 */ Run # 3370 Normal good /* Normal stop requested by offline. Subfile 68 was lost */ Run # 3371 Normal good /* Normal stop due to 24 hour rule. GONG error GONG 27 thru 30 and GONG 3 thru 6 at 2:52. More GONG errors 3:16 */ Run # 3372 Normal good /* Normal stop for LINAC job */ Run # 3373 Normal bad /* anticollector dead */ Run # 3374 Normal good Run # 3375 Normal good /* Normal stop to start LINAC job, which was actually started one hour before end of run, making anti trigger rate higher */ Run # 3376 Normal good /* Normal stop to start LINAC run. At start of run ATM board E961046 inserted at Hut 3 Crate 12 Slot 18 to take LINAC data */ Run # 3377 LINAC bad /* Run did not start, anticollector segmenta- tion fault */ Run # 3378 LINAC bad /* anti is off */ Run # 3379 LINAC good /* LINAC trigger to ATM 3-12-18 ch0 40dB attenuation. Logbook does not make clear whether this comment applies to this run or the next run */ Run # 3380 LINAC good Run # 3381 Normal good /* Stopped because of only anti HEADER */ Run # 3382 LINAC good /* 15 MeV/c */ Run # 3383 LINAC good /* L.E. H.E. and LINAC trigger all on */ Run # 3384 Normal good /* Normal stop to do LINAC */ Run # 3385 LINAC good /* 8 MeV/c */ Run # 3386 LINAC good /* 8 MeV/c plus normal trigger */ Run # 3387 Normal good /* Normal stop to do LINAC */ Run # 3388 LINAC good /* 6 MeV/c */ Run # 3389 LINAC good /* 6 MeV/c */ Run # 3390 Normal good /* Normal stop to do LINAC */ Run # 3391 LINAC good /* 5 MeV/c */ Run # 3392 LINAC good /* 5 MeV/c */ Run # 3393 Normal bad /* sukon9 collector timeout */ Run # 3394 Normal bad /* called junk by operators */ Run # 3395 Normal bad Run # 3396 Normal good /* Many bad subfiles at end of run (like maybe a dozen?) LE trigger stopped 18:30, almost two hours before run was stopped */ Run # 3397 Normal good /* Normal stop because of 24 hour rule */ Run # 3398 Normal good /* Normal stop for online test */ Run # 3399 Normal bad Run # 3400 Test bad /* 164 mV associated trigger on */ Run # 3401 Test bad Run # 3402 Test bad Run # 3403 Test bad Run # 3404 Test bad Run # 3405 Test bad Run # 3406 Test bad Run # 3407 Test bad Run # 3408 Test bad Run # 3409 Test bad Run # 3410 Test bad Run # 3411 Test bad Run # 3412 Test bad Run # 3413 Test bad Run # 3414 Test bad Run # 3415 Test bad Run # 3416 Test bad /* No logbook entry */ Run # 3417 Test bad /* No logbook entry */ Run # 3418 Test bad /* No logbook entry */ Run # 3419 Test bad /* No logbook entry */ Run # 3420 LINAC good /* Ge test */ Run # 3421 Normal bad /* Co-60,Cs-137,Cf-252 at tank top */ Run # 3422 Normal bad /* Stopped because OD FIFO busy */ Run # 3423 Normal good /* Stopped to measure water transparency */ Run # 3424 Normal bad /* Stopped because OD FIFO busy */ Run # 3425 Normal good /* Stopped to measure water transparency */ Run # 3426 Normal good /* Normal stop because of 24 hour rule */ Run # 3427 Normal good /* Normal stop requested by offline */ Run # 3428 Normal good /* Normal stop to start Ni calib */ Run # 3429 Cf bad /* Sorter sds serial count error */ Run # 3430 Cf good /* z = -12 m */ Run # 3431 Cf good /* z = 0 m */ Run # 3432 Cf good /* z = 12 m */ Run # 3433 Ni bad /* + Cf, z = -12 m, evbuild disk error */ Run # 3434 Ni good /* + Cf, z = -12 m */ Run # 3435 Ni good /* + Cf, z = 0 m */ Run # 3436 Ni good /* + Cf, z = 12 m */ Run # 3437 Normal good /* Stopped because FIFO VME busy */ Run # 3438 Normal good /* Stopped because of Hut 1 HV error */ Run # 3439 Normal bad /* No OD */ Run # 3440 Normal bad /* OD HV Hut 1 off */ Run # 3441 Normal good /* Last 6 subruns probably bad because Hut 1 HV off */ Run # 3442 Normal bad /* OD HV Hut 1 cards 1,2,3 off */ Run # 3443 Normal bad /* collector dead on sukante */ Run # 3444 Normal good /* Normal stop because of 24 hour rule */ Run # 3445 Normal good /* Stopped because FIFO VME busy */ Run # 3446 Normal bad Run # 3447 Normal good /* Stopped because of only anti HEADER */ Run # 3448 Normal good /* Normal stop requested by offline */ Run # 3449 Normal good /* Normal stop requested by offline */ Run # 3450 Normal good /* Normal stop requested by offline. OD HV Hut 3 ch 3.1 trips reset 10:15, 13:35 */ Run # 3451 Normal good /* Stopped because again OD HV problem */ Run # 3452 Normal bad /* OD HV investigation */ Run # 3453 Normal bad /* sukant collector dead */ Run # 3454 Normal bad /* Stopped for OD test */ Run # 3455 Normal bad /* OD test */ Run # 3456 Normal good /* First two subruns probably bad because of OD HV errors in all huts. Continued OD HV H3 ch 3.1 trips */ Run # 3457 Normal bad /* OD test run. OD 3-2-18-6 removed at end of run */ Run # 3458 Normal good /* Normal stop to do test runs */ Run # 3459 Normal bad /* OD test run, split trigger */ Run # 3460 Normal bad /* OD test run, split trigger */ Run # 3461 Normal good /* Stopped because of sukonh sender errors. OD HV Hut 1 ch 1.9 tripped at 08:00 and tube 9 was removed during run. */ Run # 3462 Normal good /* Last 3 subruns bad because of Hut 1 ID HV trip, which convinced operators to stop run. GPS power turned off ten minutes into run. BADSEL error at 20 minutes into run (2 subfiles) */ Run # 3463 Normal good /* Normal stop for OD test */ Run # 3464 Test bad /* OD test */ Run # 3465 Normal good /* Took 20 to 25 minutes at start of run to get collectors to work. Normal stop for OD split trigger test */ Run # 3466 Normal bad /* sukon6 stuck */ Run # 3467 Test bad /* Burst thresh 70mV Lowe 250 mV */ Run # 3468 Normal good Run # 3469 Normal good /* Normal stop for OD test */ Run # 3470 Test bad Run # 3471 Normal good /* Normal stop for OD test */ Run # 3472 Test bad /* OD test run */ Run # 3473 Normal bad /* Anticollector dead */ Run # 3474 Normal good /* Normal stop for OD test */ Run # 3475 Test bad /* OD test run gain x 2 */ Run # 3476 Test bad /* OD test run gain x 2 */ Run # 3477 Test bad /* OD test run Ni trigger -250 mV thr */ Run # 3478 Test bad /* OD test run LE HE periodic trigger */ Run # 3479 Normal good /* Normal stop for OD test */ Run # 3480 Test bad /* OD test run split trig LE 248 mV HE 28 */ Run # 3481 Test bad /* OD test run split trig LE 248 mV HE 28 */ Run # 3482 Test bad /* OD test run split trig LE 248 mV HE 30 */ Run # 3483 Normal good /* Normal stop to remove OD #20727, 3-1-9-7 flasher candidate */ Run # 3484 Normal good /* Normal stop because of 24 hour rule. Still getting hits from 3-1-9-7. Hits are due to electronic problem and should be ignored */ Run # 3485 Normal good /* Normal stop to do OD test run */ Run # 3486 Test bad /* OD test run split trig LE 248 mV HE 34 */ Run # 3487 Test bad /* OD test run split trig LE 248 mV HE 30 */ Run # 3488 Test bad /* OD test run split trig LE 248 mV HE 28 */ Run # 3489 Test bad /* OD test run split trig LE 248 mV HE 26 */ Run # 3490 Normal good /* Normal stop for 24 hour rule, but ID HV crate 43 stopped returning data five hours into run . Replaced at end */ Run # 3491 Normal bad /* ID HV crate 43 replaced during this run */ Run # 3492 Normal good /* Normal stop for OD test runs */ Run # 3493 Test bad /* OD split trigger */ Run # 3494 Test bad /* OD split trigger */ Run # 3495 Normal good /* Stopped because of sukon2 sender errors */ Run # 3496 Normal good /* Stopped because of only anti HEADER */ Run # 3497 Normal good /* Stopped because of sukon5 sender errors */ Run # 3498 Normal good /* Last one or two subruns bad because of investigation of HV error OD Hut 1 ch 1.9 */ Run # 3499 Normal good /* Stopped because display unchanged 11:40 to 12:00 */ Run # 3500 Normal bad /* sukant collector died */ Run # 3501 Normal bad /* Unsuccessful restart after 3500 */ Run # 3502 Normal bad /* Unsuccessful restart after 3500 */ Run # 3503 Normal bad /* Unsuccessful restart after 3500 */ Run # 3504 Normal good /* Normal stop to do OD test run */ Run # 3505 Test bad /* Test LE 248 mV HE 24 mV nice = 20 */ Run # 3506 Test bad /* Test LE 248 mV HE 24 mV */ Run # 3507 Test bad /* Test LE 248 mV HE 22 mV */ Run # 3508 Normal bad /* Anticollector died */ Run # 3509 Normal good /* Normal stop for OD test run */ Run # 3510 Test bad /* Test LE 248 mV HE 26 mV split trig nice = 20 */ Run # 3511 Test bad /* Test LE 248 mV HE 26 mV split trig nice = 0 */ Run # 3512 Test bad /* Test nice = 20 */ Run # 3513 Normal good /* Normal stop due to 24 hour rule */ Run # 3514 Normal good /* Normal stop for FDDI cable maintenance */ Run # 3515 Normal good /* Stopped because of sukonh evbuild/TIMEOUT */ Run # 3516 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 2 ch 2.2 tripped twice near beginning of run, enabled */ Run # 3517 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 4 ch 1.1 tripped often around 0728, enabled */ Run # 3518 Normal good /* Stopped because of only anti HEADER. GPS error for 3 to 4 minutes at 18:45*/ Run # 3519 Normal good /* Stopped because anticollector dead */ Run # 3520 Normal bad /* only anti HEADER */ Run # 3521 Normal bad /* sender and sorter dead */ Run # 3522 Nonexistent bad Run # 3523 Normal good /* Normal stop because of 24 hour rule */ Run # 3524 Normal bad /* Sukant: collector died */ Run # 3525 Normal good /* Stopped because of sukonh evbuild sorter errors */ Run # 3526 Normal bad /* only anti HEADER */ Run # 3527 Normal bad /* anticollector dead */ Run # 3528 Normal bad /* anticollector dead */ Run # 3529 Nonexistent bad Run # 3530 Nonexistent bad Run # 3531 Normal bad /* anti HV off */ Run # 3532 Normal good /* Normal stop requested by offline */ Run # 3533 Normal good /* Normal stop for OD test */ Run # 3534 Test bad Run # 3535 Normal good /* Stopped to investigate OD trips. At 06:00 Hut 1 ch 0.7 and Hut 2 ch 1.10 tripped and there were continued problems with both channels. */ Run # 3536 Test bad /* Jumper removed form OD Hut 1 ch 0.7 tube 9 which is crate 1, card 8, cable 20081 */ Run # 3537 Normal good /* Normal stop to check trigger timing */ Run # 3538 Test bad /* SLE thr 240; super LE trigger test box on */ Run # 3539 Normal good /* Normal stop to search for flasher */ Run # 3540 Test bad /* Several tubes turned on and off during run. Hut 1 crate 2 card 17 tube 8 identified as flasher and jumper removed */ Run # 3541 Normal good /* Stopped to do OD DAQ tests */ Run # 3542 Test bad /* LE thr 248; HE 26 */ Run # 3543 Test bad /* LE 248; HE 24 */ Run # 3544 Test bad /* Le 220; HE 22 */ Run # 3545 Normal bad /* OD DAQ problems */ Run # 3546 Normal good /* Stopped by evbuild buf_kind invalid */ Run # 3547 Normal bad /* evbuild buf_kind invalid */ Run # 3548 Normal bad /* Search for flasher */ Run # 3549 Normal bad /* Search for flasher */ Run # 3550 Normal good /* Normal stop to reboot sukslc */ Run # 3551 Normal good /* Normal stop because of 24 hour rule */ Run # 3552 Normal good /* Stopped because of ID HV error cable 8527 crate 24-5-14 */ Run # 3553 Test bad /* ID test with 24-5-14m off */ Run # 3554 Normal good /* Normal stop for OD online test */ Run # 3555 Test bad Run # 3556 Test bad /* OD DAQ froze: Hut 1 error */ Run # 3557 Test bad /* LE thr 248; HE 34; burst thr 122 */ Run # 3558 Test bad /* LE 248; HE 34; burst 48 */ Run # 3559 Test bad /* OD DAQ froze */ Run # 3560 Normal good /* normal stop: turn off hvs for laser run */ Run # 3561 Laser bad /* hvs off for laser run */ Run # 3562 Laser bad /* hvs off filter 1250 */ Run # 3563 Laser bad /* hvs off filter 1450 */ Run # 3564 Laser bad /* hvs off filter 1450 */ Run # 3565 Laser bad /* hvs off filter 1400 */ Run # 3566 Laser bad /* hvs off filter 1350 */ Run # 3567 Laser bad /* hvs off filter 1300 */ Run # 3568 Laser bad /* hvs off filter 1250 */ Run # 3569 Laser bad /* hvs off filter 1200 */ Run # 3570 Laser bad /* hvs off filter 1150 for 2000 events, 1100 for 800 events, 1050 for 800, then 600 events each for filters 1000 400 in decrements of 50 */ Run # 3571 Normal bad /* OD FIFO error */ Run # 3572 Normal bad /* OD FIFO error */ Run # 3573 Normal good /* Normal stop for 24 hour rule. OD HV channel 2.2 from unspecified hut went dead at 14:45, restarted */ Run # 3574 Normal good /* Stopped at 11:50 to replace ATM board ID Hut 1-7-6 which was discovered to be bad at 06:20 */ Run # 3575 Normal good /* ATM trouble Hut 1-3-2 at 14:00 discovered to be broken at end of run at 00:34 */ Run # 3576 Normal good /* Norm stop anticipating offline shutdown ATM Hut 1-3-2 still bad. GPS errors at beginning */ Run # 3577 Normal good /* Suketto shut down 16:56 run aborted ATM Hut 1-3-2 still bad */ Run # 3578 Normal good /* Stopped to replace ATM 1-3-2 */ Run # 3579 Normal good /* Normal stop because of 24 hour rule */ Run # 3580 Normal good /* Normal stop for trigger test. OD HV trip Hut 2 ch 2.2 enabled 02:47 */ Run # 3581 Test bad /* trigger test */ Run # 3582 Normal good /* Normal stop for 24 hour rule. OD HV trip Hut 3 ch 2.1 10:50 enabled, 11:52 enabled. OD HV trip Hut 2 ch 2.2 enabled 16:09 and 16:19 */ Run # 3583 Normal good /* Stopped because no OD Hut 1 tubes */ Run # 3584 Normal bad /* pmonitor/collector dead on sukante */ Run # 3585 Normal good /* Stopped for ATM calibration */ Run # 3586 Normal good /* Stopped to remove OD PMT 21011 as suspected flasher (later restored when ID 6092 identified as culprit). OD HV trip Hut 2 ch 2.2 at 01:55 */ Run # 3587 Normal bad /* FIFO busy */ Run # 3588 Normal good /* Stopped to return OD PMT 21011 mto service and remove ID 6092 as suspected flasher */ Run # 3589 Normal good /* Stopped to remove ID 4557 suspected flasher */ Run # 3590 Normal good /* Normal stop because of 24 hour rule */ Run # 3591 Normal good Run # 3592 Normal bad /* ID DAQ problems */ Run # 3593 Normal bad /* OD Hut 2 FSCC error */ Run # 3594 Test bad /* OD split trigger supernova simulation test */ Run # 3595 Normal good /* Normal stop because of 24 hour rule */ Run # 3596 Normal good /* Normal stop to restart US tape process */ Run # 3597 Test bad /* OD PMT test */ Run # 3598 Test bad /* OD PMT test */ Run # 3599 Normal good /* Normal stop to start supernova sim test */ Run # 3600 Test bad /* OD split trigger supernova simulation test */ Run # 3601 Normal good /* Stopped to remove flasher candidate ID 10734 OD 537 Hut 2-1-5-10 */ Run # 3602 Normal good /* Stopped to prepare Ni calibration */ Run # 3603 Normal bad /* Unsuccessful start of normal run. Ni given up because container leaked. */ Run # 3604 Normal bad /* Unsuccessful start */ Run # 3605 Normal good /* Normal stop because of 24 hour rule. OD HV Hut 1 ch 1.9 trip 8:43:53 enabled 8:45 */ Run # 3606 Normal good /* Normal stop to test temperature effect on ATM */ Run # 3607 Normal good /* Normal stop because of 24 hour rule */ Run # 3608 Normal good /* Stopped because of sukon 4 sender error */ Run # 3609 Normal good /* Normal stop because of 24 hour rule */ Run # 3610 Normal good /* Stopped to do supernova sim test run */ Run # 3611 Test bad /* OD test supernova simulation */ Run # 3612 Normal good Run # 3613 Normal bad /* sukant::anticollector FSCC reset flag */ Run # 3614 Normal good /* Normal stop for water transparency test */ Run # 3615 Test bad /* veto test ID OD HV off */ Run # 3616 Test bad /* OD HV off */ Run # 3617 Test bad /* Burst test trigger */ Run # 3618 Test bad /* OD HV off */ Run # 3619 Test bad /* OD HV off */ Run # 3620 Test bad /* OD HV off */ Run # 3621 Test bad /* online test run */ Run # 3622 Test bad /* online test run */ Run # 3623 Normal bad /* only anti HEADER */ Run # 3624 Normal good /* Stopped for OD test run */ Run # 3625 Test bad /* Test new version anticollector to fix GPS bug */ Run # 3626 Normal bad /* Anti Hut 4 off */ Run # 3627 Normal good /* Stopped because OTHER flag */ Run # 3628 Normal good /* Stopped to test suspect flasher ID 6276 */ Run # 3629 Test bad /* Flasher check. ID 6276 removed */ Run # 3630 Normal good /* Stopped for water transparency measurement */ Run # 3631 Test bad /* Test run for veto counter */ Run # 3632 Test bad /* Test run for veto counter */ Run # 3633 Test bad /* Test run for veto counter */ Run # 3634 Test bad /* Test run for veto counter */ Run # 3635 Test bad /* Test run for veto counter */ Run # 3636 Normal good /* OD HV H 4 3.1.5 tripped, removed after run */ Run # 3637 Normal good /* Stopped to test Ni fission source */ Run # 3638 Normal good /* Stopped to restart off-line */ Run # 3639 Normal good /* Stopped to restart off-line */ Run # 3640 Normal good /* Stopped for OD DAQ supernova simulation */ Run # 3641 Test bad /* OD DAQ supernova simulation */ Run # 3642 Normal good /* Stopped to restart off-line */ Run # 3643 Normal good /* Stopped to test fission counter */ Run # 3644 Normal bad /* anticollector dead */ Run # 3645 Normal bad /* anticollector dead */ Run # 3646 Normal good /* Stopped to start Ni calibration */ Run # 3647 Ni bad /* No data to sukonh */ Run # 3648 Ni bad Run # 3649 Ni bad /* Trigger logic has bug */ Run # 3650 Ni bad /* Invalid SDS FLAG */ Run # 3651 Ni good /* z = +12 m */ Run # 3652 Ni good /* z = 0 m */ Run # 3653 Ni good /* z = -12 m */ Run # 3654 Ni good /* z = +16 m */ Run # 3655 Normal bad /* only anti HEADER */ Run # 3656 Normal bad /* only anti HEADER */ Run # 3657 Normal good /* Normal stop to take more Ni data */ Run # 3658 Ni good /* (x,y,z) = (0,-12,-12) m */ Run # 3659 Ni good /* (x,y,z) = (0,-12,0) m */ Run # 3660 Ni good /* (x,y,z) = (0,-12,12) m */ Run # 3661 Ni good /* (x,y,z) = (0,-12,12) m */ Run # 3662 Ni good /* (x,y,z) = (0,-12,16) m */ Run # 3663 Ni good /* (x,y,z) = (0,-16,-12) m */ Run # 3664 Ni good /* (x,y,z) = (0,-16,-12) m */ Run # 3665 Ni good /* (x,y,z) = (0,-16,0) m */ Run # 3666 Ni good /* (x,y,z) = (0,-16,12) m */ Run # 3667 Ni good /* (x,y,z) = (0,-16,16) m */ Run # 3668 Ni good /* (x,y,z) = (0,12,-12) m */ Run # 3669 Ni good /* (x,y,z) = (0,12,0) m */ Run # 3670 Ni good /* (x,y,z) = (0,12,12) m */ Run # 3671 Ni good /* (x,y,z) = (0,12,16) m */ Run # 3672 Ni good /* (x,y,z) = (12,0,-12) m */ Run # 3673 Ni bad /* (x,y,z) = (12,0,0) m sukon2 inv ATM */ Run # 3674 Ni good /* (x,y,z) = (12,0,0) m */ Run # 3675 Ni good /* (x,y,z) = (12,0,12) m */ Run # 3676 Ni bad /* (x,y,z) = (12,0,16) m inv SDS FLAG */ Run # 3677 Ni bad /* (x,y,z) = (12,0,16) m inv SDS FLAG */ Run # 3678 Ni good /* (x,y,z) = (12,0,16) m */ Run # 3679 Ti good /* (x,y,z) = (0,0,0) m */ Run # 3680 Normal good /* Normal stop for SN watcher replacement */ Run # 3681 Normal good /* Run stopped suddenly and was aborted */ Run # 3682 Normal good /* Normal stop due to 24 hour rule */ Run # 3683 Normal good /* Stopped because only anti HEADER */ Run # 3684 Normal bad /* sukant collector died */ Run # 3685 Normal bad /* online process not working */ Run # 3686 Normal good /* Normal stop for offline problem */ Run # 3687 Normal good /* Stopped to update SN monitor */ Run # 3688 Normal good /* Normal stop due to 24 hour rule */ Run # 3689 Normal good /* Stopped to check ATM threshold. OD HV H 1 ch 1.2 tripped, reenabled several times starting 19:40 */ Run # 3690 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 4 ch 2.7 trip 22:05 enabled */ Run # 3691 Normal good /* Normal stop due to 24 hour rule. OD HV Hut 4 ch 2.7 trip 06:49 enabled */ Run # 3692 Normal good /* Stopped to do special run */ Run # 3693 Normal bad /* One HV crate not working */ Run # 3694 Test bad /* I am calling this a test run because HV ID crate 48 was replaced in the middle of the run at 18:30 */ Run # 3695 Normal good /* Normal stop to do online test */ Run # 3696 Test bad /* Online test */ Run # 3697 Test bad /* Online test */ Run # 3698 Test bad /* Online test */ Run # 3699 Test bad /* Online test */ Run # 3700 Test bad /* Online test */ Run # 3701 Test bad /* Online test */ Run # 3702 Test bad /* Online test */ Run # 3703 Test bad /* Online test */ Run # 3704 Test bad /* Online test */ Run # 3705 Test bad /* Online test */ Run # 3706 Test bad /* Online test */ Run # 3707 Normal bad /* Characterized as junk by operators */ Run # 3708 Normal good /* Stopped because sukon7 sender died */ Run # 3709 Normal good Run # 3710 Test bad /* Super LowE trigger test */ Run # 3711 Test bad /* Super LowE trigger test */ Run # 3712 Test bad /* Super LowE trigger test */ Run # 3713 Normal bad /* Anti sorter did not work */ Run # 3714 Normal good /* Stopped by operator error */ Run # 3715 Normal good /* Normal stop due to 24 hour rule */ Run # 3716 Normal bad /* OD TDC busy Hut 2 */ Run # 3717 Normal good /* Stopped to remove old SN watch */ Run # 3718 Normal good /* Normal stop due to 24 hour rule */ Run # 3719 Normal good /* Normal stop due to 24 hour rule */ Run # 3720 Normal good /* Stopped to reboot Kingfish after multiple SKIM restarts */ Run # 3721 Normal good /* Stopped because of continued Kingfish problems */ Run # 3722 Normal good /* Stopped because only anti HEADER, continued Kingfish problems */ Run # 3723 Normal bad /* sukant collector died */ Run # 3724 Normal good /* Stopped because sukant collector died */ Run # 3725 Normal good /* Stopped because badsel err=95 */ Run # 3726 Normal good /* Stopped to do test run */ Run # 3727 Test bad /* Nova buffer size too small */ Run # 3728 Test bad Run # 3729 Test bad Run # 3730 Test bad Run # 3731 Test bad Run # 3732 Normal good /* HV of veto counters turned on at 20:10, 25 minutes into run. Trigger rate increased 8:00 suspect flasher */ Run # 3733 Test bad /* OD#1628 HV Hut 4-1-16-9 disconnected as flasher */ Run # 3734 Normal good /* Stopped to do nickel runs */ Run # 3735 Ni good /* x,y,z = (0,0,-12) m */ Run # 3736 Ni good /* x,y,z = (0,0,0) m */ Run # 3737 Ni good /* x,y,z = (0,0,12) m */ Run # 3738 Normal good /* Stopped because sukon9 collector did not run */ Run # 3739 Normal good /* Stopped to start LINAC */ Run # 3740 Normal bad /* LINAC was operating and caused sorter errors. Stopped because sukant collector died *(/ Run # 3741 Normal bad /* sukant collector dead */ Run # 3742 Normal good /* Stopped to search for flasher candidate */ Run # 3743 Normal bad /* sukant collector dead */ Run # 3744 Normal good /* Anti HV 04 went off at 20:09 with panic off lights on. Was reset and run halted */ Run # 3745 Normal good /* Normal stop due to 24 hour rule */ Run # 3746 Normal good /* Stopped because of OD HV trips, H 4 ch 2.7 */ Run # 3747 Normal good /* Stopped because of OD HV trips, H 4 ch 2.7 */ Run # 3748 Normal good /* Stopped because of OD HV trips, H 4 ch 2.7 */ Run # 3749 Normal good /* Normal stop to recompile OD software */ Run # 3750 Normal good /* Normal stop to do Ni runs */ Run # 3751 Ni bad /* x,y,z = -12.37,-.707,12.06 m; sukant collector, sorter, sender died */ Run # 3752 Ni good /* x,y,z = -12.37,-.707,12.06 m; ATM thr = 100 */ Run # 3753 Ni good /* x,y,z = -12.37,-.707,12.06 m; ATM thr = 100 */ Run # 3754 Ni good /* x,y,z = -12.37,-.707,12.06 m; ATM thr = -100 */ Run # 3755 Normal good /* Normal stop due to 24 hour rule */ Run # 3756 Normal good /* Normal stop to connect veto counter cable to ATM */ Run # 3757 Normal good Run # 3758 Normal good /* Normal stop due to 24 hour rule */ Run # 3759 Normal good /* OD HV trip H 2 ch 1.3 enabled 11:50 */ Run # 3760 Normal good /* OD HV trip H 2 ch 1.3 enabled 12:25 */ Run # 3761 Normal good /* Normal stop due to 24 hour rule */ Run # 3762 Normal bad /* sukant collector died */ Run # 3763 Normal good /* Normal stop due to 24 hour rule. OD HV trip H 2 ch 1.3 enabled 12:30 */ Run # 3764 Normal good /* Senders died after Kingfish rebooted */ Run # 3765 Normal good /* Stopped because offline processes died */ Run # 3766 Normal good /* Normal stop due to 24 hour rule */ Run # 3767 Normal good /* Stopped for split trigger test */ Run # 3768 Test bad /* Superlow trigger */ Run # 3769 Test bad /* Superlow trigger */ Run # 3770 Test bad /* Superlow trigger */ Run # 3771 Normal good /* Normal stop due to 24 hour rule */ Run # 3772 Normal good /* Stopped to restart offline. OD HV trip 3-2-12-6 tripped several times then pulled */ Run # 3773 Normal bad /* sukonh::evbuild/CANNOT write data to disk */ Run # 3774 Normal good /* Normal stop due to 24 hour rule */ Run # 3775 Normal good /* Stopped for super LowE trigger test */ Run # 3776 Test bad /* SLE test */ Run # 3777 Test bad /* SLE test */ Run # 3778 Normal good /* Stopped for Xe data taking */ Run # 3779 Xe good /* LED z = 1 */ Run # 3780 Xe good Run # 3781 Xe bad Run # 3782 Xe bad /* anti-collector died */ Run # 3783 Xe good /* z = 3 */ Run # 3784 Xe good Run # 3785 Xe good /* LED z = 5 */ Run # 3786 Xe bad Run # 3787 Xe bad Run # 3788 Xe good Run # 3789 Xe good Run # 3790 Xe good Run # 3791 Xe bad Run # 3792 Xe good /* LED */ Run # 3793 Xe bad Run # 3794 Xe good Run # 3795 Xe good /* LED */ Run # 3796 Xe good Run # 3797 Xe good /* LED */ Run # 3798 Xe good Run # 3799 Xe bad Run # 3800 Xe good /* LED */ Run # 3801 Xe bad Run # 3802 Xe good Run # 3803 Xe good /* LED */ Run # 3804 Xe good Run # 3805 Xe good /* LED */ Run # 3806 Xe good Run # 3807 Normal good /* Normal stop due to 24 hour rule */ Run # 3808 Normal good /* Stopped because sukon8 sender died */ Run # 3809 Normal good /* Stopped for OD tube work */ Run # 3810 Test bad /* OD tube work */ Run # 3811 Test bad /* anticollector dead */ Run # 3812 Test bad Run # 3813 Test bad /* to check online */ Run # 3814 Test bad /* for veto counter */ Run # 3815 Test bad Run # 3816 Test bad /* SLE test */ Run # 3817 Test bad /* SLE test */ Run # 3818 Test bad /* SLE test */ Run # 3819 Test bad /* SLE test */ Run # 3820 Test bad /* SLE test */ Run # 3821 Normal bad /* anticollector did not start */ Run # 3822 Normal good /* sukon6 sender died */ Run # 3823 Normal bad /* anticollector did not start */ Run # 3824 Normal good /* HV ID crate 43 down at 5:36. Last two subruns probably bad */ Run # 3825 Normal good /* sukon7 sorter died */ Run # 3826 Normal good /* Hut 4 crate #7 (crate 43) ID HV went off some time between 17:13 and 17:23. Last 2 or 3 subruns bad */ Run # 3827 Normal good /* Stopped because ID HV 43 down. OD HV H 2 ch 3.2 tripped enabled 20:57 */ Run # 3828 Normal good /* Stopped because OD HV Hut 2 ch 0.5 tripped at 12:15. Remove #20379 2-1-6-5 */ Run # 3829 Test bad /* Hut 2 HV test */ Run # 3830 Normal bad /* sukant sender dead */ Run # 3831 Normal bad /* no antidata */ Run # 3832 Normal bad Run # 3833 Normal bad Run # 3834 Normal bad Run # 3835 Normal bad Run # 3836 Normal bad Run # 3837 Normal good /* Normal stop due to 24 hour rule */ Run # 3838 Normal good /* Stopped because sender on sukon9 dead */ Run # 3839 Normal good /* Stopped because sender on sukon9 dead */ Run # 3840 Normal good /* Stopped: TQReal skipped many files */ Run # 3841 Normal good /* Stopped because OFFline MONitor not working */ Run # 3842 Normal bad /* FIFO VME busy */ Run # 3843 Normal good /* Stopped because of evbuild invalid SDS flag. OD HV H 1 ch 2.1 tripped, enabled */ Run # 3844 Normal bad /* sukon7 collector setup failed */ Run # 3845 Normal good /* Stopped because offline flow stopped */ Run # 3846 Normal good /* Stopped because ID HVPS suspected trip */ Run # 3847 Normal bad /* Missing HV crate 43, 47 */ Run # 3848 Test bad /* OD VME busy */ Run # 3849 Normal good /* Stopped because offline flow stopped */ Run # 3850 Normal bad /* OD VME busy */ Run # 3851 Normal good /* Stopped because many unmatched events, antisorter@sukant, last two subruns bad */ Run # 3852 Normal bad /* FSCC error Hut 4 */ Run # 3853 Normal good /* Stopped by LINAC group request */ Run # 3854 Test bad /* LINAC test run */ Run # 3855 Normal bad Run # 3856 Test bad /* sukon 5,6,7,8 off */ Run # 3857 Normal good /* all senders died */ Run # 3858 Normal good Run # 3859 Test good /* SLE test */ Run # 3860 Test good /* SLE test */ Run # 3861 Test good /* SLE test */ Run # 3862 Test bad /* OD VME FIFO busy */ Run # 3863 Test good /* SLE test */ Run # 3864 Normal bad /* Stopped because disk full on sukonh. Too many OD tube hits */ Run # 3865 Normal bad /* anticollector dead */ Run # 3866 Normal good /* stopped for offline computer shutdown */ Run # 3867 Normal good /* Stop requested by LINAC group */ Run # 3868 Normal good /* Stop to install new ATM for LINAC data */ Run # 3869 Normal good /* Stopped because H 3 ch 36 hitsum cable in wrong module. Problem may be one week old */ Run # 3870 Normal bad /* Sukon problems */ Run # 3871 Normal good /* Stopped because sorter on sukante died */ Run # 3872 Normal bad /* VME FIFO busy */ Run # 3873 Normal bad /* VME FIFO busy */ Run # 3874 Normal bad /* VME FIFO busy */ Run # 3875 Normal bad /* VME FIFO busy */ Run # 3876 Normal bad /* Hut 2 TDC busy */ Run # 3877 Normal bad Run # 3878 Normal bad Run # 3879 Test bad /* without anti */ Run # 3880 Test bad /* without anti */ Run # 3881 Normal bad /* sukant off */ Run # 3882 Normal bad /* DAQ trouble */ Run # 3883 Normal good /* Stopped because no anti data */ Run # 3884 Normal bad /* DAQ trouble */ Run # 3885 Normal good /* Stopped for LINAC beam tuning */ Run # 3886 Normal good /* Stopped for final LINAC preparation. OD HV H3 ch 2.1 tripped, enabled 11:40 */ Run # 3887 LINAC good /* 15 MeV */ Run # 3888 LINAC bad /* OD DAQ error */ Run # 3889 LINAC bad Run # 3890 LINAC good /* 15 MeV */ Run # 3891 Normal good /* Plus 15 MeV LINAC */ Run # 3892 Normal bad Run # 3893 Normal bad Run # 3894 Normal good /* LINAC veto */ Run # 3895 LINAC good /* 8 MeV */ Run # 3896 LINAC bad /* 8 MeV, sukon sender dead */ Run # 3897 LINAC good /* 8 MeV */ Run # 3898 Normal bad Run # 3899 LINAC good /* 6 MeV */ Run # 3900 Normal good Run # 3901 LINAC good /* 5 MeV */ Run # 3902 Normal good /* normal stop for LINAC */ Run # 3903 LINAC bad /* 10 MeV */ Run # 3904 LINAC bad /* 10 MeV */ Run # 3905 LINAC good /* 10.6 MeV */ Run # 3906 Normal good /* with LINAC */ Run # 3907 LINAC good /* 12 MeV */ Run # 3908 Normal good /* Stopped for only anti HEADER */ Run # 3909 Test bad /* ID test, stopped FIFO busy */ Run # 3910 Test bad /* Stopped for only anti HEADER */ Run # 3911 Test bad Run # 3912 Normal good /* Normal stop to set LINAC */ Run # 3913 Normal bad Run # 3914 Test good /* SLE test */ Run # 3915 Test good /* SLE test */ Run # 3916 Normal good /* Stopped because anti busy */ Run # 3917 Normal good /* Normal stop for OD DAQ test */ Run # 3918 Test bad Run # 3919 Test bad Run # 3920 Test bad Run # 3921 Test bad Run # 3922 Test bad Run # 3923 Test bad Run # 3924 Test bad Run # 3925 Test bad Run # 3926 Normal good /* Stopped to set up LINAC */ Run # 3927 Normal good /* Stopped to set up LINAC */ Run # 3928 LINAC good /* 15 MeV */ Run # 3929 Normal good /* Plus LINAC 15 MeV */ Run # 3930 Normal good Run # 3931 LINAC good /* Plus LE plus HE */ Run # 3932 Normal good Run # 3933 LINAC good /* Plus LE plus HE */ Run # 3934 Normal good Run # 3935 LINAC good /* 5.8 MeV */ Run # 3936 LINAC good Run # 3937 Normal bad /* OD collector dead */ Run # 3938 Normal good /* Stopped to start LINAC */ Run # 3939 LINAC good /* 8 MeV */ Run # 3940 Normal good /* Sukant sender error */ Run # 3941 Normal bad /* OD collector dead */ Run # 3942 Normal bad /* OD collector dead */ Run # 3943 Normal good /* Sukon5 sender error */ Run # 3944 Normal good /* only OD header */ Run # 3945 Normal good /* Normal stop for OD DAQ tests */ Run # 3946 Test bad /* anticollector dead */ Run # 3947 Test bad /* anticollector dead */ Run # 3948 Test good Run # 3949 Test good Run # 3950 Normal good /* Stopped because sukonh SENDER[2] dead */ Run # 3951 Normal good /* Stopped sukon5 sorter/SMP memory overflow */ Run # 3952 Normal good /* Normal stop because of 24 hour rule */ Run # 3953 Normal good /* Normal stop because no data seen on Kingfish but logfile shows data */ Run # 3954 Normal good /* Normal stop for OD DAQ test */ Run # 3955 Normal good /* BIP trigger test but neglected to #define BIP in makefile */ Run # 3956 Normal bad /* TDC busy */ Run # 3957 Normal good /* BIP trigger test */ Run # 3958 Normal good /* sukon2,6,5 emergency stop, not enough outbufsize */ Run # 3959 Ni good /* z = 12 m stopped invalid SDS */ Run # 3960 Ni good /* z = 0 */ Run # 3961 Normal bad /* no anti data */ Run # 3962 Normal good /* Normal stop because of 24 hour rule */ Run # 3963 Normal good /* SLE thr 246 Normal stop to test OD DAQ */ Run # 3964 Test good Run # 3965 Normal good /* Normal stop to do Ni */ Run # 3966 Ni good /* (0,0,-12m) */ Run # 3967 Ni good /* (0,0,0) */ Run # 3968 Ni bad /* (0,0,12m) */ Run # 3969 Ni good /* (0,0,12m) */ Run # 3970 Normal good /* Normal stop to remove noisy tubes */ Run # 3971 Normal good /* Normal stop for OD DAQ tests */ Run # 3972 Normal bad /* OD Hut 3 busy */ Run # 3973 Normal bad /* OD Hut 2 busy */ Run # 3974 Normal bad /* OD Hut 1 and 4 busy */ Run # 3975 Normal bad /* OD Hut 2 busy */ Run # 3976 Normal bad /* OD Hut 2 busy */ Run # 3977 Normal bad /* OD Hut 2 busy */ Run # 3978 Normal bad /* OD Hut 2 busy */ Run # 3979 Normal good /* Stopped because no anticounter data */ Run # 3980 Normal bad /* OD Hut 3 TDC busy */ Run # 3981 Normal bad /* OD Hut 3 TDC busy */ Run # 3982 Normal bad /* OD is missing */ Run # 3983 Test bad /* sukant off */ Run # 3984 Normal bad /* OD is missing */ Run # 3985 Test bad /* sukant off */ Run # 3986 Normal bad /* did not start */ Run # 3987 Normal good /* sukon5 sender errors */ Run # 3988 Normal good /* Normal stop to restart offline */ Run # 3989 Normal good /* Normal stop to restart offline */ Run # 3990 Normal good /* Normal stop because of noisy PMTs. Turned off 3706,3708,3758,3573 */ Run # 3991 Normal good /* Normal stop to remove flasher OD 1368 */ Run # 3992 Normal bad /* TDC busy Hut 3 */ Run # 3993 Normal bad /* TDC busy Hut 3 */ Run # 3994 Test bad /* OD 1368 determined to be bad QTC, and few hits in H2 crate 1 card 4 */ Run # 3995 Test bad Run # 3996 Normal bad /* I am judging this bad because the QTC problem and the poor hit map in OD 2.1.6.1-7 was not completely fixed until near the end of this one hour run. Stopped to check bad ID channels */ Run # 3997 Test good /* SLE test thr = 264 mV */ Run # 3998 Test good /* SLE test thr = 262 mV */ Run # 3999 Normal good /* Stopped because sender on sukante dead */ Run # 4000 Normal good /* Normal stop to start SLE test */ Run # 4001 Normal good /* SLE 260 mV with subruns 27-30 unfiltered */ Run # 4002 Normal good /* Split trigger was still on */ Run # 4003 Normal bad /* FSCC busy */ Run # 4004 Normal bad /* FSCC busy */ Run # 4005 Normal bad /* FSCC busy */ Run # 4006 Normal good /* Stopped because sukon6 sender dead */ Run # 4007 Normal good /* Stopped because sukante collector dead */ Run # 4008 Normal good /* Stopped because sukant collector dead */ Run # 4009 Normal good /* Normal stop for SLE test */ Run # 4010 Normal good /* SLE test thr=260 mV */ Run # 4011 Normal good /* Stopped because of ID trip */ Run # 4012 Normal bad /* ID HV trip */ Run # 4013 Normal bad /* ID HV trip */ Run # 4014 Normal good /* Stopped because of OD HV 3.2.1 trip */ Run # 4015 Normal good /* Stopped because of OD HV 3.2.1 trip */ Run # 4016 Normal good /* Stopped because of OD HV 3.2.1 trip */ Run # 4017 Normal good /* Removed OD 3.2.1.10 PMT */ Run # 4018 Normal good /* Normal stop because of 24 hour rule */ Run # 4019 Normal bad /* No TDC in OD DAQ */ Run # 4020 Normal good /* Stopped because sender@sukant dead */ Run # 4021 Normal good /* Normal stop because of 24 hour rule */ Run # 4022 Normal good /* Stopped because OD HV 2.2.11 */ Run # 4023 Normal good /* Normal stop because of 24 hour rule */ Run # 4024 Normal bad /* TDC busy */ Run # 4025 Normal bad /* TDC busy */ Run # 4026 Normal good /* Normal stop to restart offline */ Run # 4027 Normal good /* Stopped because disk full (sukonh evbuild) */ Run # 4028 Normal good /* Stopped because FIFO VME busy */ Run # 4029 Test good /* 1 pe IDHV x2 gain ATM -100 mV Ni TRIG 320 mV preset 500 microsec times 25 Hz */ Run # 4030 Test good /* 1 pe ATM -50 mV others as in # 4029 */ Run # 4031 Test good /* 1 pe IDHV normal others as in # 4030 */ Run # 4032 Ni good /* z = 0 m */ Run # 4033 Ni good /* z = -12 m */ Run # 4034 Ni good /* z = +12 m */ Run # 4035 Normal good /* Stopped because OD HV trip ch 4.2.11 */ Run # 4036 Test bad /* Normal trigger ch 4.2.11 problem not found */ Run # 4037 Normal good /* OD HV trip ch 4.2.11 */ Run # 4038 Test bad /* Normal trigger ch 4.2.11 restored */ Run # 4039 Normal good /* Normal stop to for flasher */ Run # 4040 Normal good /* OD HV trip ch 4.2.11 */ Run # 4041 Test bad /* Normal trig PMT cable # 21660 removed from OD 4-2-16-11 */ Run # 4042 Normal good Run # 4043 Test bad /* Stopped because OD collector and sender dead. QTC tests on normal trigger */ Run # 4044 Test bad /* QTC tests on normal trigger */ Run # 4045 Normal bad /* Cable from paddle card 2.2.12 plugged in wrong way leading to 12 missing tubes on TOP of detector */ Run # 4046 Normal good Run # 4047 Normal good /* Normal stop due to 24 hour rule */ Run # 4048 Normal good /* Normal stop for SLE test */ Run # 4049 Test good /* SLE test */ Run # 4050 Normal good /* Stopped because sender died 13:34 but GETREAL died at 12:50 */ Run # 4051 Normal good /* Normal stop to change offline process */ Run # 4052 Normal good /* Normal stop because ID H4 Crate 7 missing for last subrun */ Run # 4053 Normal bad /* normal, but ID H4 Cr 7 missing throughout run */ Run # 4054 Normal good /* Stopped because sukante sorter, collector dead */ Run # 4055 Normal good /* Normal stop to start SLE */ Run # 4056 Normal good /* SLE thr = 260 mV. Stopped because Event Builder disk full */ Run # 4057 Normal good /* Normal stop for scattering measurement */ Run # 4058 Xe good /* Stopped because HV off */ Run # 4059 Test bad /* Sukant off */ Run # 4060 Test bad Run # 4061 Test bad Run # 4062 Test bad Run # 4063 Test bad Run # 4064 Test bad Run # 4065 Xe good Run # 4066 Xe good /* Scatter 365 */ Run # 4067 Xe good /* Scatter 400 */ Run # 4068 Xe good /* Scatter 400 */ Run # 4069 Xe good /* Scatter 400 */ Run # 4070 Xe good /* Scatter 400 */ Run # 4071 Xe good /* Scatter 420 */ Run # 4072 Xe good /* Scatter 420 */ Run # 4073 Xe good /* Scatter 420 */ Run # 4074 Xe good /* Scatter 420 */ Run # 4075 Xe good /* Scatter 460 */ Run # 4076 Xe good /* Scatter 460 */ Run # 4077 Xe bad Run # 4078 Xe good /* Scatter 500 */ Run # 4079 Normal bad Run # 4080 Normal good /* Plus SLE. Stopped because sender 8,10 dead */ Run # 4081 Normal bad /* Did not start */ Run # 4082 Normal good /* Plus SLE stopped because reformat problem */ Run # 4083 Normal good /* Normal stop to switch from split to regular trigger */ Run # 4084 Normal good /* Normal stop to replace board */ Run # 4085 Normal good /* Normal stop to change to SLE */ Run # 4086 Normal good /* SLE 260 mV */ Run # 4087 Normal bad /* Hut 2 TDC busy */ Run # 4088 Normal good /* stopped by sukonh evbuild disk full */ Run # 4089 Normal bad Run # 4090 Normal good /* disk full error was false */ Run # 4091 Normal good /* with SLE, false full error fixed */ Run # 4092 Normal good /* without SLE but with split trigger. Normal stop */ Run # 4093 Normal good /* with SLE, stopped by NETSERVIT dead */ Run # 4094 Normal good /* Normal stop to stress test SLE */ Run # 4095 Normal good /* SLE stress test, not good for SLE */ Run # 4096 Normal good /* SLE test, not good for SLE */ Run # 4097 Normal good /* No SLE, OD ch # 1368 possible QTC induced flasher */ Run # 4098 Normal good /* Normal stop due to 24 hour rule */ Run # 4099 Normal bad /* OD DAQ hang */ Run # 4100 Normal good /* Stopped because of sukon5 sorter uncompleted ATM flag */ Run # 4101 Normal good /* Stopped because sukon9 sender dead */ Run # 4102 Normal good /* Normal stop for new TQREAL on offline */ Run # 4103 Normal good /* Normal stop to look for flashers */ Run # 4104 Test bad /* OD HV turned on and off during run */ Run # 4105 Test good /* OD HV H 3 ch 1.2 and 0.1 briefly off at beginning. Disabled OD # 979 to try to reduce noise in ID # 3993 but it had no effect */ Run # 4106 Normal good /* Normal stop to test decay-e trigger */ Run # 4107 Test bad /* decay-e trigger test */ Run # 4108 Test bad /* decay-e trigger test */ Run # 4109 Test bad /* decay-e trigger test */ Run # 4110 Test bad /* decay-e trigger test */ Run # 4111 Normal good /* Normal stop to start SLE. DOUBLE PULSE PROBLEM IN SPLIT TRIGGER, this run through 4166 */ Run # 4112 Normal good /* SLE thr 260 stop req offline */ Run # 4113 Normal good /* Stop to remove SLE trigger, netservit hung */ Run # 4114 Normal good /* Normal stop to start decay-e trigger */ Run # 4115 Test good /* decay-e trigger */ Run # 4116 Test good /* Normal trigger */ Run # 4117 Normal bad /* DAQ set up wrong */ Run # 4118 LINAC good /* z=+12,x=0A,y=0A */ Run # 4119 LINAC good /* z=+12,x=+0.25A,y=0A */ Run # 4120 LINAC good /* z=+12,x=0A,y=+0.25A */ Run # 4121 LINAC good /* x=0A,y=0.1A */ Run # 4122 LINAC good /* x=0A,y=-0.25A */ Run # 4123 LINAC good /* x=-0.25A,y=0 */ Run # 4124 LINAC good /* (x,y)=(0,0)A */ Run # 4125 LINAC good /* (x,y,z)=(0A,0A,+12) */ Run # 4126 Normal good /* With SLE. sukon4,7 GONG at 05:29. There is a note on Run # 4128 that Hut 1 ch 0.2 and part of 0.3 look dead on hitmap, possible QTC problem true for several hours, which would extend it back to much of this run. */ Run # 4127 Test good /* decay-e trigger */ Run # 4128 Normal bad /* QTC problem noted in Run # 4126 */ Run # 4129 Test bad /* Test to find QTC problem */ Run # 4130 Test good /* decay-e trigger */ Run # 4131 LINAC good /* 5MeV x=+0.05A,y=+0.05A */ Run # 4132 LINAC good /* 5MeV x=+0.15A,y=+0.05A */ Run # 4133 LINAC good /* 5MeV x=+0.05A,y=+0.15A */ Run # 4134 LINAC good /* 5MeV x=-0.02A,y=+0.05A */ Run # 4135 LINAC good /* 5MeV x=0.05A,y=-0.07A */ Run # 4136 Test good /* Normal trigger */ Run # 4137 LINAC good /* 5MeV x=+0.4A,y=+0.05A,D3=6.41A */ Run # 4138 LINAC good /* 5MeV x=-0.3A,y=+0.025,D3=6.54A */ Run # 4139 LINAC good /* 5MeV x=+0.12,y=+0.05,F3=6.47A */ Run # 4140 LINAC good /* 5MeV x=+0.1A,y=+0.08A,D3=6.47A */ Run # 4141 Normal bad /* Hut 1 OD hitsum high */ Run # 4142 Normal good /* With SLE. GONG errors 1:03 sukon6 GONG- 35,36; sukon3 GONG-17,18. 01:05 sukon5 GONG-27,28,29,30. 03:37 sukon3 GONG-17, sukon4 GONG-24, sukon6 GONG-35, sukon7 GONG-41,42, sukon5 GONG-29,30, sukon1 GONG-5,6. 06:27 sukon4 GONG-19. 07:41 sukon7 GONG-42, sukon3 GONG-18, sukon6 GONG-18,sukon1 GONG-1, sukon5 GONG-30. 09:15 GONGs in sukon1,3-8 */ Run # 4143 Normal good Run # 4144 LINAC good /* 8MeV x=0.05,y=+0.05 */ Run # 4145 Test bad /* Test run for LINAC */ Run # 4146 LINAC good /* 10MeV */ Run # 4147 Test bad /* LINAC veto, reformatter errors */ Run # 4148 LINAC good /* 12MeV */ Run # 4149 Test bad /* no OD */ Run # 4150 LINAC good /* 6MeV */ Run # 4151 Test bad /* no OD */ Run # 4152 LINAC good /* 4MeV */ Run # 4153 Test bad /* no OD */ Run # 4154 Normal good /* with SLE stopped for sukon6 sender error */ Run # 4155 Normal bad /* sukon4 sender error */ Run # 4156 Normal good /* Frequent only anti HEADER on sukonh */ Run # 4157 Normal bad /* OD DAQ hung Hut 3 */ Run # 4158 Normal good /* sukant collector died */ Run # 4159 Normal good /* Stopped because can't write data to disk */ Run # 4160 Normal bad /* Can't write to disk */ Run # 4161 Normal good Run # 4162 Normal bad /* netserv dead */ Run # 4163 Normal bad /* No OD Hut4 */ Run # 4164 Normal bad /* sukon9 sender dead */ Run # 4165 Normal good /* At 22:30 sukon7 GONG-37,38,40 */ Run # 4166 Normal good /* At 06:33 sukon7 GONG-41,42; sukon6 GONG-36, sukon8 GONG-47.48; sukon3 GONG-17,48. At 07:56 sukon3 GONG-15,17,18; sukon2 GONG-9,11,12; sukon5 GONG-29,30; sukon1 GONG-4,5,6. There is no SLE data from an unkown subrun between 81 and 129 up to subrun 136. At 17:22 GONGs too numerous to mention in sukon1-8. Stopped to fix double pulse problem in split trigger. */ Run # 4167 Normal good /* Subrun 40 has no SLE. 01:33 sukon5 GONG- 29,30; sukon1 GONG-5,6; sukon3 GONG 17,18; sukon8 GONG-47,48; sukon2 GONG-11, 12; sukon7 GONG-41,42; sukon6 GONG-34,35,36. Stopped sukon4 sender died */ Run # 4168 Normal good /* Stopped sukonh evbuild add-evnt buf-kind INVALID SDS Flag. 09:37 sukon7 GONG-41, sukon8 GONG-48, sukon6 GONG-35, sukon2 GONG-12, sukon1 GONG-5 */ Run # 4169 Normal good /* sukon5 sorter serial count error */ Run # 4170 Normal good /* Stopped sukon8 sender frozen. Subruns 42 through 45 have no SLE */ Run # 4171 Normal good /* Normal stop for LINAC. 08:24 sukon6 GONG-31,32 */ Run # 4172 Test good /* LINAC test for veto */ Run # 4173 Ni good /* z = -12 m */ Run # 4174 Ni good /* z = 0 m. 11:37 GONG 45-48. 11:55 GONG 3-6,9-12. 12:00 GONG 33-36 */ Run # 4175 Ni good /* z = +12 m */ Run # 4176 Ni bad /* z = + 18.1 m. */ Run # 4177 Ni good /* z = +18.1 m. sukon8 GONG-45,46,47,48 */ Run # 4178 Ni good /* Ni at LINAC z = +12 m. sukon1 GONG 3-6 */ Run # 4179 Normal bad /* ID HV-16 off */ Run # 4180 Normal bad /* only anti HEADER */ Run # 4181 Normal good /* Stopped because sukon3 sender dead */ Run # 4182 Normal good /* Stopped because sukon6 sender error */ Run # 4183 Normal bad /* No OD data */ Run # 4184 Normal good /* pmonitor disappeared */ Run # 4185 Normal good /* Stopped SKITTER not running */ Run # 4186 Normal good /* Stopped sukon6 sender dead */ Run # 4187 Normal good /* SKITTER not running. Not good for SLE */ Run # 4188 Normal good /* Normal stop instal ntwrk sniffer on FDDI. Run includes SLE */ Run # 4189 Normal good /* Stopped SKITTER not running */ Run # 4190 Normal good /* Stopped sukonh disk full */ Run # 4191 Normal good /* sukon1 sender error */ Run # 4192 Normal good /* Normal stop due to 24 hour rule */ Run # 4193 Normal bad /* No OD data */ Run # 4194 Normal good /* Stopped for QTC test */ Run # 4195 Normal good /* Abnormal stop for unknown reason. OD 3-2-15-1 pulled just before this run. */ Run # 4196 Normal good /* Stopped for sukon6 sender error */ Run # 4197 Normal good /* Stopped because sukon7 sender dead */ Run # 4198 Normal good /* Stopped for sukon5 sender error */ Run # 4199 Normal good /* No OD data */ Run # 4200 Normal good /* Stopped for sukon8 sender error */ Run # 4201 Normal good /* Normal stop for 24 hour rule */ Run # 4202 Normal good /* Stopped for sukon1 sender error */ Run # 4203 Normal good /* Stopped for sukon1 sender error */ Run # 4204 Normal good /* Stopped to reboot sukonx */ Run # 4205 Normal good /* anti-trigger off */ Run # 4206 Normal bad Run # 4207 Normal good /* Stopped because OD stopped */ Run # 4208 Normal bad /* Stopped because no OD data */ Run # 4209 Normal bad /* Continued anticollector problems */ Run # 4210 Normal good /* Stopped for sukon5 sender errors */ Run # 4211 Normal good Run # 4212 Normal good Run # 4213 Normal good /* Stopped for sukon8 sender error */ Run # 4214 Normal good Run # 4215 Normal good Run # 4216 Normal good /* Stopped because sukon6 sender error */ Run # 4217 Normal bad /* Did not start */ Run # 4218 Normal good /* Stopped for sukon6 sender error */ Run # 4219 Normal good /* Stopped for sukon7 sender error */ Run # 4220 Normal good /* Stopped for sukon8 sender error */ Run # 4221 Normal bad /* No OD TDC Hut 1,2,3,4 */ Run # 4222 Normal good /* Stopped because sukon7 sender died. No SLE trigger since subrun # 50 */ Run # 4223 Normal good Run # 4224 Normal good /* SKITTER errors. SLE file was successfully sent beginning with subrun # 78 */ Run # 4225 Normal good /* Stopped because sukonh sender 3 dead and sukon4 sender error */ Run # 4226 Normal good /* Stopped because of sukon1 sender errors */ Run # 4227 Normal good /* Stopped because of sukon8 sender error */ Run # 4228 Normal bad /* sukant/collector no OD TDC data */ Run # 4229 Normal good /* Stopped for no OD TDC data. SKITTER errors No SLE data at least for subruns 66-73 */ Run # 4230 Normal good /* Normal stop for FDDI check */ Run # 4231 Normal bad /* FDDI analyzer could not catch up */ Run # 4232 Normal good /* Stopped: sukonh evbuild/sender[5] dead */ Run # 4233 Normal good /* Stopped because sukon6 crashed. Many skitter size errors */ Run # 4234 Normal good Run # 4235 Normal bad /* No anticounter data */ Run # 4236 Normal bad /* No anticounter data */ Run # 4237 Normal bad /* No anticounter data */ Run # 4238 Normal good /* Stopped sukon8 sender error */ Run # 4239 Normal good /* Stopped for FDDI check */ Run # 4240 Normal bad /* No OD TDC data */ Run # 4241 Normal good /* Stopped by sukon7 sender error. No SLE data error at 23:08 */ Run # 4242 Normal bad /* No anticounter data */ Run # 4243 Normal good /* Stopped because of sukon6 sender error */ Run # 4244 Normal good /* Trigger rate became inconstant one half hour before run stopped. Badsel alarm 26 minutes into run */ Run # 4245 Normal good /* Stopped to do flasher search */ Run # 4246 Normal bad /* Flasher search. OD HV off Hut 1 ch 2.10 and 2.11 during unknown part of run. Cable # 21761 (1-2-15-2) removed */ Run # 4247 Normal good /* Normal stop for Ni data taking */ Run # 4248 Ni good /* z = -12 m */ Run # 4249 Ni good /* z = 0 m aborted */ Run # 4250 Ni good /* z = 12 m */ Run # 4251 Normal good /* Stopped because SLE not on */ Run # 4252 Normal good /* With SLE. Stopped for sukon[n] serial count error */ Run # 4253 Normal bad /* Without sukon4 */ Run # 4254 Normal bad /* Without sukon4 */ Run # 4255 Normal bad /* Without sukon4 */ Run # 4256 Normal bad Run # 4257 Normal good /* Stopped because sukon8 sender problem */ Run # 4258 Normal good /* Normal stop requested by offline */ Run # 4259 Normal good /* Stopped by sukon6 sender error. No SLE subruns 16 to 20 and 118 */ Run # 4260 Normal bad /* Sukon8 sender error */ Run # 4261 Normal good /* Stopped because sukon5e not connected via ethernet */ Run # 4262 Normal good /* Stopped for sukon5 sender error */ Run # 4263 Normal good /* Normal stop for online maintenance */ Run # 4264 Normal good /* Stopped sukon4-7 sender error */ Run # 4265 Normal good /* Stopped for sukon6 sender error */ Run # 4266 Normal good /* Normal stop for 24 hour rule. No SLE for subrun 93 */ Run # 4267 Normal bad /* No OD data */ Run # 4268 Normal good /* Normal stop for 24 hour rule */ Run # 4269 Normal good /* Normal stop for 24 hour rule. No SLE subruns 53,85-88 */ Run # 4270 Normal good /* Normal stop for laser run. Skitter died ten and a half hours into run but recovered */ Run # 4271 Xe bad Run # 4272 Xe good /* Laser calibration */ Run # 4273 Xe good /* Laser at z = -5m */ Run # 4274 Xe good /* Laser */ Run # 4275 Xe bad /* Laser dummy run */ Run # 4276 Xe bad /* Laser */ Run # 4277 Test bad /* Flat cable not connected to VME. Run halted when problem fixed. */ Run # 4278 Xe good /* Laser at z = 0 m */ Run # 4279 Xe good /* Laser at z = 5 m */ Run # 4280 Xe good /* Laser at z = 10 m */ Run # 4281 Xe bad /* pmonitor/collector setup failed on sukon2e */ Run # 4282 Xe bad /* same error as # 4281 */ Run # 4283 Xe good /* Laser */ Run # 4284 Xe good /* Laser at z = -5 m */ Run # 4285 Xe good /* Laser */ Run # 4286 Xe good /* Laser at z = 0 m */ Run # 4287 Xe good /* Laser at z = 5 m */ Run # 4288 Xe good /* Laser at z = 10 m */ Run # 4289 Xe good /* Laser at z = -5 m; w 420 */ Run # 4290 Xe good /* Laser at z = -5 m; w 420 */ Run # 4291 Xe good /* Laser at z = -5 m; w 420 */ Run # 4292 Xe good /* Laser at z = 0 m; w 420 */ Run # 4293 Xe good /* Laser at z = 5 m; w 420 */ Run # 4294 Xe good /* Laser at z = 10 m; w 420 */ Run # 4295 Xe bad /* sukon9 error */ Run # 4296 Xe bad /* No data */ Run # 4297 Xe good /* Laser at z = -5 m; w 460 */ Run # 4298 Xe good /* Laser at z = 0 m; w 460 */ Run # 4299 Xe good /* Laser at z = 5 m; w 460 */ Run # 4300 Xe good /* Laser at z = 10 m; w 460 */ Run # 4301 Xe good /* Laser pedestal run */ Run # 4302 Normal good /* Stopped to repair sender@sukant. OD HV Hut 1 turned itself off twice during run and restored itself (once at 0605, 1 hr 42 min into run) */ Run # 4303 Normal good /* anti trigger rate increased due to Linac test. Normal stop to move beam pipe. */ Run # 4304 Normal good /* Stopped for sender error. Removed jumper for OD ch 1859 cable 21679 before run */ Run # 4305 Normal good /* No SLE vectors subruns 41 to 45 */ Run # 4306 Normal good /* Normal stop to start decay electron run */ Run # 4307 LINAC good /* Decay e trigger */ Run # 4308 LINAC good /* 15 MeV z = 0 */ Run # 4309 LINAC good /* Test with anti HV off */ Run # 4310 LINAC good /* LINAC 12 MeV z = 0 & LE & anti-trig HE off */ Run # 4311 LINAC good /* With HE and LE but anti-trig off */ Run # 4312 LINAC good /* 10 MeV w LE & HE w anti-trig off */ Run # 4313 Test good /* LE & HE w anti-trig off */ Run # 4314 LINAC good /* 8 MeV w LE & HE w anti-trig off */ Run # 4315 Normal bad /* sukant off */ Run # 4316 Normal good /* Normal stop to start LINAC */ Run # 4317 LINAC good /* 6 MeV z = 0 */ Run # 4318 Test bad /* LE,HE,periodic OD off */ Run # 4319 LINAC good /* 5 MeV z = 0 */ Run # 4320 Test bad /* LE,HE,periodic OD off */ Run # 4321 LINAC good /* 4.8 MeV LINAC & LE & HE, anti-trig off z = 0 */ Run # 4322 Test good /* LE,HE,periodic. anti-trig off */ Run # 4323 Test good /* SLE & LE & HE & periodic. anti-trig off */ Run # 4324 Normal good /* SLE & LE & HE & periodic & anti-trig. Stopped for sukon5,6,8,9 sender errors */ Run # 4325 Normal good /* Normal stop to update SENDER software */ Run # 4326 Normal good /* Stopped for sukon2 sender error. SLE & LE & HE & periodic */ Run # 4327 Normal bad Run # 4328 Normal good /* Stopped for sukon1 sender error */ Run # 4329 Normal good /* Stopped for sender error */ Run # 4330 Normal good /* Normal stop req by offline. SLE & LE & HE & periodic */ Run # 4331 Normal good /* Stopped for sukon6 sender error. SLE & LE & HE & periodic */ Run # 4332 Normal good /* Stopped for sukon6 sender error */ Run # 4333 Normal good /* Normal stop to start LINAC test */ Run # 4334 Normal good /* Normal stop for Ni runs */ Run # 4335 Ni good /* x = -12 m, z = 0 */ Run # 4336 Normal good /* Stopped for sukon2 sender dead */ Run # 4337 Normal good /* Stopped for sukon4 sender error */ Run # 4338 Normal bad Run # 4339 Normal good /* Stopped for sukon3 sender dead */ Run # 4340 Normal good /* Stopped for sukon4 sender dead */ Run # 4341 Normal good /* Normal stop for 24 hour rule. Next run contains comment no TKO V or T or core readings since 0700, which would go back to 3 hours before the end of this run . This means no error diagnostics */ Run # 4342 Normal good /* Stopped because no OD data. TKO crate malfuctioning so no HV error diagnostics */ Run # 4343 Normal bad /* Only anti HEADER */ Run # 4344 Normal bad /* Run did not start */ Run # 4345 Normal good /* Stopped to exchange HV board. No SLE data subruns 11-15 and 37-41 and probably more since netservit, ntsrvit & skitter were discovered stopped at beginning of shift 1. ID HV #16 in red condition 20 minutes before run ended */ Run # 4346 Test bad /* Exchanged ID HV board 16-5 */ Run # 4347 Normal good /* Stopped for sukon8 sender error */ Run # 4348 Normal good /* Normal stop to take Xe data */ Run # 4349 Xe bad /* DAQ stuck */ Run # 4350 Xe bad /* DAQ stuck */ Run # 4351 Xe bad /* DAQ stuck */ Run # 4352 Xe bad /* High rate switch not set */ Run # 4353 Xe bad /* OD DAQ stuck */ Run # 4354 Xe bad /* No OD data */ Run # 4355 Xe good /* Test for light leak */ Run # 4356 Xe good /* z = 1 */ Run # 4357 Xe good /* LED, z = 1 */ Run # 4358 Xe good /* LED, z = 3 */ Run # 4359 Xe good /* z = 3 */ Run # 4360 Xe good /* LED, z = 5 */ Run # 4361 Xe good /* z = 5 */ Run # 4362 Xe good /* LED, z = 7 */ Run # 4363 Xe good /* z = 7 */ Run # 4364 Xe good /* LED, z = 9 */ Run # 4365 Xe good /* z = 9 */ Run # 4366 Xe good /* LED, z = 11 */ Run # 4367 Xe good /* z = 11 */ Run # 4368 Xe bad /* sukon9 collector invalid address */ Run # 4369 Xe good /* LED, z = 13 */ Run # 4370 Xe good /* z = 13 */ Run # 4371 Xe good /* LED, z = 15 */ Run # 4272 Xe good /* z = 15 */ Run # 4373 Xe good /* LED, z = 17 */ Run # 4374 Xe good /* z = 17 */ Run # 4375 Normal good /* Stopped because of sukonh evbuild cannot write data to disk. Appeared 0200, run stopped 0220 */ Run # 4376 Normal good /* Normal stop due to 24 hour rule */ Run # 4377 Normal good /* Stopped by sukon5 not connected via ethernet */ Run # 4378 Normal good /* Normal stop to look for flasher */ Run # 4379 Normal good /* Normal stop to install new off-line */ Run # 4380 Normal good /* Stopped for sukon6 sender dead */ Run # 4381 Normal good /* Stopped because sorter error in TKO19 Hut 2 TKO7 */ Run # 4382 Normal good /* Stopped for sukon8 sender error */ Run # 4383 Normal good /* Stopped by sukon1 sender dead */ Run # 4384 Normal good /* Stopped for sukon6,8 sender errors */ Run # 4385 Normal good /* Normal stop to install new OD DAQ program */ Run # 4386 Normal good /* Normal stop to disconnect suspected ID Flasher. Disconnected cable # 21693, ch 1856, Hut 4-2-15-9 */ Run # 4387 Normal bad /* Stopped because no anti-data and jump in trigger rate. The problem with this run is that PMTs 1848 to 1859 were dead due to an improperly positioned card. */ Run # 4388 Normal bad /* Actually good except for aforementiontioned mispositioned card, which was fixed at end of run */ Run # 4389 Normal good /* Stopped by sukon3 sender dead */ Run # 4390 Normal good /* Normal stop to restart offline */ Run # 4391 Normal good /* Normal stop req by offline. Skit1 needed to be restarted 48 minutes before end of run. Some SLE probably lost */ Run # 4392 Normal good /* Stopped for no OD TDC data. Continued skitter (SLE) problems: 15:55 (14 hours into run) netservit crash. repeat. netservit killed and restarted. Skit2 restarted 0.6 hours later */ Run # 4393 Test bad /* Search for bad OD tube. OD HV 3-1-11-7 removed */ Run # 4394 Normal good /* Stopped because sukon7 sender dead */ Run # 4395 Normal good /* Stopped for sukon4 sender error */ Run # 4396 Normal good /* Stopped for sukon8 sender error */ Run # 4397 Normal good /* Normal stop to work on OD PMTs */ Run # 4398 Normal bad /* Normal but OD HV is off and on */ Run # 4399 Normal bad /* Continued OD PMT work in Hut 4 */ Run # 4400 Normal good /* probably only first two subruns are good. 13 minutes into run Hut 3 ch 0.1 tripped, and 3-1-2-6 was removed */ Run # 4401 Normal good /* Stopped by sukon4,8 sender error */ Run # 4402 Normal good /* Stopped for sukon8 sorter invalid ATM in TKO 48 (Hut4-TKO12) */ Run # 4403 Normal good /* Stopped for sukon6 sender errors which go back to 98 minutes before end of run */ Run # 4404 Normal good /* Normal stop to restart offline. GPS signal error due to power failure about eight hours into run. GPS was off from then on. No SLE from subrun 170 to end of run */ Run # 4405 Normal good /* Stopped for sukon9 sender error. GPS down throughout run */ Run # 4406 Normal good /* Normal stop to regenerate mgsctl window. GPS back on 3 hours into run */ Run # 4407 Normal good /* Normal stop due to operator's mistaken notion that 24 hours had passed. No SLE for subruns 51 to 79 due to ntsrvit dead. Recovered at 08:17 */